TraceMgrPacketReadFirst (FUN)ΒΆ
FUNCTION TraceMgrPacketReadFirst : RTS_IEC_HANDLE
Reads the contents of the first record.
Note
if the result code is ERR_ENTRIES_REMAINING, data has been successfully copied to pTraceBuffer, but more data can be read by a subsequent call. (Either because the destination buffer was too small, or because new data has been recorded in the mean time.)
Note
You should call TraceMgrPacketReadBegin before calling this function, to make sure any outstanding trace values are written to the trace buffers.
Note
Data is always returned in little endian byte order even if the device has big endian byte order.
- InOut:
Scope
Name
Type
Comment
Return
TraceMgrPacketReadFirstRTS_IEC_HANDLE- Returns the runtime system error code (see CmpErrors.library):
ERR_PARAMETER if hPacket is not a valid packet handle
ERR_NO_OBJECT if the packet does not have a single record
ERR_NOTINITIALIZED if the packet is not complete
ERR_TIMEOUT if reading took too long
ERR_ENTRIES_REMAINING if more data can be read by a subsequent call (this is not an error)
Input
hPacketRTS_IEC_HANDLEThe trace packet handle
Inout
pTraceBufferPointer to the destination buffer
pulReadBytesUDINTSize of the destination buffer in bytes (in), number of bytes copied (out)
pResultRTS_IEC_RESULTThe result code