DNP3_DataCallbacks_Outstation (STRUCT)ΒΆ
TYPE DNP3_DataCallbacks_Outstation : STRUCT
- InOut:
Name
Type
Initial
Comment
cbf_binInQuantityPOINTER TO BYTE
ADR(DNP3_DataCallback_binInQuantity)
callback function pointer to binInQuantity
cbf_binInGetPointPOINTER TO BYTE
ADR(DNP3_DataCallback_binInGetPoint)
callback function pointer to binInGetPoint
cbf_binOutQuantityPOINTER TO BYTE
ADR(DNP3_DataCallback_binOutQuantity)
callback function pointer to binOutQuantity
cbf_binOutGetPointPOINTER TO BYTE
ADR(DNP3_DataCallback_binOutGetPoint)
callback function pointer to binOutGetPoint
cbf_binCntrQuantityPOINTER TO BYTE
ADR(DNP3_DataCallback_binCntrQuantity)
callback function pointer to binCntrQuantity
cbf_binCntrGetPointPOINTER TO BYTE
ADR(DNP3_DataCallback_binCntrGetPoint)
callback function pointer to binCntrGetPoint
cbf_binCntrGetFrzPointPOINTER TO BYTE
ADR(DNP3_DataCallback_binCntrGetFrzPoint)
callback function pointer to binCntrGetFrzPoint
cbf_frznCntrQuantityPOINTER TO BYTE
ADR(DNP3_DataCallback_frznCntrQuantity)
callback function pointer to frznCntrQuantity
cbf_frznCntrGetPointPOINTER TO BYTE
ADR(DNP3_DataCallback_frznCntrGetPoint)
callback function pointer to frznCntrGetPoint
cbf_anlgInQuantityPOINTER TO BYTE
ADR(DNP3_DataCallback_anlgInQuantity)
callback function pointer to anlgInQuantity
cbf_anlgInGetPointPOINTER TO BYTE
ADR(DNP3_DataCallback_anlgInGetPoint)
callback function pointer to anlgInGetPoint
cbf_anlgInGetFreezePointPOINTER TO BYTE
ADR(DNP3_DataCallback_anlgInGetFreezePoint)
callback function pointer to anlgInGetFreezePoint
cbf_frznAnlgInQuantityPOINTER TO BYTE
ADR(DNP3_DataCallback_frznAnlgInQuantity)
callback function pointer to frznAnlgInQuantity
cbf_frznAnlgInGetPointPOINTER TO BYTE
ADR(DNP3_DataCallback_frznAnlgInGetPoint)
callback function pointer to frznAnlgInGetPoint
cbf_anlgInDBandQuantityPOINTER TO BYTE
ADR(DNP3_DataCallback_anlgInDBandQuantity)
callback function pointer to anlgInDBandQuantity
cbf_anlgInDBandGetPointPOINTER TO BYTE
ADR(DNP3_DataCallback_anlgInDBandGetPoint)
callback function pointer to anlgInDBandGetPoint
cbf_anlgOutQuantityPOINTER TO BYTE
ADR(DNP3_DataCallback_anlgOutQuantity)
callback function pointer to anlgOutQuantity
cbf_anlgOutGetPointPOINTER TO BYTE
ADR(DNP3_DataCallback_anlgOutGetPoint)
callback function pointer to anlgOutGetPoint
cbf_dblInQuantityPOINTER TO BYTE
ADR(DNP3_DataCallback_dblInQuantity)
callback function pointer to dblInQuantity
cbf_dblInGetPointPOINTER TO BYTE
ADR(DNP3_DataCallback_dblInGetPoint)
callback function pointer to dblInGetPoint