DNP3_DataCallbacks_BinaryOutput (STRUCT)¶
TYPE DNP3_DataCallbacks_BinaryOutput : STRUCT
Data callback function pointers to access BinaryOutput
generated code - don’t modify
- InOut:
Name
Type
Initial
Comment
cbf_binOutGetDescriptionPOINTER TO BYTE
ADR(DNP3_DataCallback_binOutGetDescription)
callback function pointer to binOutGetDescription
cbf_binOutDefVariationPOINTER TO BYTE
ADR(DNP3_DataCallback_binOutDefVariation)
callback function pointer to binOutDefVariation
cbf_binOutEventClassPOINTER TO BYTE
ADR(DNP3_DataCallback_binOutEventClass)
callback function pointer to binOutEventClass
cbf_binOutIsClass0POINTER TO BYTE
ADR(DNP3_DataCallback_binOutIsClass0)
callback function pointer to binOutIsClass0
cbf_binOutEventDefVariationPOINTER TO BYTE
ADR(DNP3_DataCallback_binOutEventDefVariation)
callback function pointer to binOutEventDefVariation
cbf_binOutEventModePOINTER TO BYTE
ADR(DNP3_DataCallback_binOutEventMode)
callback function pointer to binOutEventMode
cbf_binOutAssignClassPOINTER TO BYTE
ADR(DNP3_DataCallback_binOutAssignClass)
callback function pointer to binOutAssignClass
cbf_binOutReadPOINTER TO BYTE
ADR(DNP3_DataCallback_binOutRead)
callback function pointer to binOutRead
cbf_binOutChangedPOINTER TO BYTE
ADR(DNP3_DataCallback_binOutChanged)
callback function pointer to binOutChanged
cbf_binOutWritePOINTER TO BYTE
ADR(DNP3_DataCallback_binOutWrite)
callback function pointer to binOutWrite
cbf_binOutGetControlMaskPOINTER TO BYTE
ADR(DNP3_DataCallback_binOutGetControlMask)
callback function pointer to binOutGetControlMask
cbf_binOutSelectPOINTER TO BYTE
ADR(DNP3_DataCallback_binOutSelect)
callback function pointer to binOutSelect
cbf_binOutCancelSelectPOINTER TO BYTE
ADR(DNP3_DataCallback_binOutCancelSelect)
callback function pointer to binOutCancelSelect
cbf_binOutOperatePOINTER TO BYTE
ADR(DNP3_DataCallback_binOutOperate)
callback function pointer to binOutOperate
cbf_binOutCmdEventDefVariationPOINTER TO BYTE
ADR(DNP3_DataCallback_binOutCmdEventDefVariation)
callback function pointer to binOutCmdEventDefVariation
cbf_binOutCmdEventModePOINTER TO BYTE
ADR(DNP3_DataCallback_binOutCmdEventMode)
callback function pointer to binOutCmdEventMode
cbf_binOutCmdEventClassPOINTER TO BYTE
ADR(DNP3_DataCallback_binOutCmdEventClass)
callback function pointer to binOutCmdEventClass
cbf_binOutCmdChangedPOINTER TO BYTE
ADR(DNP3_DataCallback_binOutCmdChanged)
callback function pointer to binOutCmdChanged
cbf_binOutCmdAssignClassPOINTER TO BYTE
ADR(DNP3_DataCallback_binOutCmdAssignClass)
callback function pointer to binOutCmdAssignClass