ReadAll (FB)ΒΆ
FUNCTION_BLOCK ReadAll EXTENDS CBM.ETrig
Reads all elements of a CSV file and saves the values in a string array.
- InOut:
- Scope - Name - Type - Initial - Comment - Inherited from - Input - xExecute- BOOLRising edge: Action startsFalling edge: Resets outputsIf a falling edge occurs before the function block has completed its action, the outputs operate in the usual manner and are only reset if either the action is completed or in the event of an error. In this case, the corresponding output values (- xDone,- xError) are present at the outputs for exactly one cycle.- ETrig - Output - xDone- BOOL- TRUE: Action successfully completed- ETrig - xBusy- BOOL- TRUE: Function block active- ETrig - xError- BOOL- TRUE: Error occurred, function block aborts action- FALSE: No error- ETrig - Input - udiMaxElementLength- UDINT- 80 - Max length of an element. - pasDataArray- POINTER TO STRING - Pointer to a string array. The lenght of the strings must be equal to udiMaxElementLength! - Inout - csvReaderInit- Initialization of the CSV reader. - Output - eError- Error code - iNumberOfElements- UDINT- Nubmer of elements 