NextElement (FB)ΒΆ
FUNCTION_BLOCK NextElement EXTENDS CBM.ETrig
Reads the next element of a CSV file.
- InOut:
- Scope - Name - Type - Initial - Comment - Inherited from - Input - xExecute- BOOLRising edge: Action startsFalling edge: Resets outputsIf a falling edge occurs before the function block has completed its action, the outputs operate in the usual manner and are only reset if either the action is completed or in the event of an error. In this case, the corresponding output values (- xDone,- xError) are present at the outputs for exactly one cycle.- ETrig - Output - xDone- BOOL- TRUE: Action successfully completed- ETrig - xBusy- BOOL- TRUE: Function block active- ETrig - xError- BOOL- TRUE: Error occurred, function block aborts action- FALSE: No error- ETrig - Input - udiMaxElementLength- UDINT- 255 - Max length of the element - xReset- BOOL- Reset the read position to the first element - psElement- POINTER TO STRING - Pointer to element to read - Inout - csvReaderInit- Initialization of the CSV reader - Output - eError- Error code - xHasNextElement- BOOL- True, if there are more elements to read 