IObjectDictionary.WriteObject (METH)ΒΆ
METHOD WriteObject : ABORT_CODE
Used to write an object in the local object dictionary. If ABORT_CODE.SUCCESSFUL is returned data in pbyData was copied to the object.
If error occured the corresponding abort code is returned.
Difference to IObjectDictionary.WriteObjectByAddress: Better performance because itfObject is an input variable => no internal binary search necessary.
- InOut:
- Scope - Name - Type - Initial - Comment - Return - WriteObject- ABORT_CODE.SUCCESSFUL: Writing successful, object value was changed according to pbyData; ELSE: Writing not permitted - Input - itfObject- Object which should be written. - bySubIndex- BYTE- Subindex of object - xCheckAccess- BOOL- TRUE - TRUE: Access rights should be checked. Write on readonly object will fail.- FALSE: Ignore access rights and force writing.- xDataInBusOrder- BOOL- Specifies Byte Order of data - pbyDatapoints to;- TRUE: Data in CANopen Byteorder (Little Endian),- FALSE: Data in Host Byte Order- pbyData- POINTER TO BYTE - Pointer to data which should be written to the object - Inout - udiSize- UDINT- VAR IN: Size of memory pbyData points to; VAR OUT: Size of Object 