IObjectDictionary.ReadObjectByAddress (METH)ΒΆ
METHOD ReadObjectByAddress : ABORT_CODE
Used to read an object of the local object dictionary. If ABORT_CODE.SUCCESSFUL is returned pbyData contains the read data.
If error occured the corresponding abort code is returned.
- InOut:
- Scope - Name - Type - Initial - Comment - Return - ReadObjectByAddress- ABORT_CODE.SUCCESSFUL: Reading successful, - pbyDatacontains data; ELSE: Reading not permitted- Input - wIndex- WORD- Index of object which should be read - bySubIndex- BYTE- Subindex of object - xCheckAccess- BOOL- TRUE - TRUE: Access rights should be checked. Reading a writeonly object will fail.- FALSE: Ignore access rights and force reading- xDataInBusOrder- BOOL- Specifies in which Byte Order data should be read; - TRUE: Data should be read in CANopen Byteorder (Little Endian),- FALSE: Data should be read in Host Byte Order- pbyData- POINTER TO BYTE - Pointer to data where the object value should be copied to. - Inout - udiSize- UDINT- VAR IN: Size of memory pbyData points to; VAR OUT: Size of Object 
