Action: MoveObjects
Function: The action moves one or more objects in the device tree to another location.
Call: Objects test driver
Tab: Configuration
New parent object | Superordinate object below which the objects to be moved are inserted If this entry is missing, then the elements are inserted at the top level.
|
Object path of all objects which are moved The objects can be added by dragging them from the device tree or by means of the command Add from navigator (multiple selection possible). Objects can be copied within the list (Clone) and then edited. Individual objects are deleted from the list by means of the Remove command. All entries of the list are deleted by means of the Clear command. | |
Insert user path | Input of a user path By clicking the command, the path is applied to the list of the objects to be moved. In this way, an object path can be specified manually that is currently not reflected in a loaded project. |
Tab: Parameters
The parameters defined on the Parameters tab are used to exchange values between test script variables and parameters of test actions. Parameters can be used as placeholders on the Configuration tab. For this, the name of the parameter is set in braces in the configuration dialog. Example: {name}.
Tip
Variables defined globally in the script (with the prefix $GLOBALS.) can be used directly in the test action. It is not necessary to use input parameters for passing. Using output parameters is necessary for writing global variables.
Input parameters: When executing the test action, the values of the test script variables are passed to the input parameters of the test action and can be used in the configuration of the test action. | |
Output parameters: When executing the test action, the values of the output parameters of the test action are passed to the test script variables and can be used (for example, in other test actions). | |
Name | Name of the input/output parameter This name is defined in addition to the variable name to identify the origin of the parameter when it is passed to another script. During the test run, this name is displayed as the Outer name on the Variables (scope #<n>) tab in the Test progress window. Background: When a script To see that this variable is recognized as variable |
Variable | Name of the test script variable Example: |
Move Up | Moves the selected variable one line up |
Move Down | Moves the selected variable one line down |
Remove | Removes the selected variable from the list |

