Skip to main content

Dialog: Manage Test Repositories

Manage Test Repositories

Function: The dialog lists all known test repositories. Here you add, edit, or remove test repositories and create the default test repository.

Call: Test Manager view, Manage Test Repositories button

Table 10. Repositories

Name

Name of the test repository in CODESYS

The name is used for display and alphabetical sorting in the Test Manager view. A test repository is identified by its location.

Location

Folder of the test repository in the file system

Example: D:\Test Manager\TestRepository_1

Add

Opens the Add Test Repository dialog. There you add an existing test repository or create a new one.

Edit

Opens the Edit Test Repository dialog for the selected test repository. There you change the name. Available only if exactly one test repository is selected.

Remove

Removes the selected test repository from the list of known test repositories

The files of the test repository in the file system are retained. You can use Add to add the test repository to the list again later.

Initialize default

Creates the empty default test repository in %LOCALAPPDATA%\CODESYS Test Manager\Test Repository

If a test repository already exists there, then it remains unchanged.

Open in Explorer

Opens the folder of the selected test repository in a new Explorer window

Available only if exactly one test repository is selected.

Refresh

Reads the list of known test repositories again from the settings file

In this way, you apply changes which were made outside of CODESYS without restarting CODESYS. An example is an update by the version control system.

Close

Closes the dialog



Important

The list of known test repositories is saved in the settings file %LOCALAPPDATA%\CODESYS Test Manager\TestManager.xml. All installations of CODESYS Test Manager 5.2.0.0 on the computer use this file.

Dialog: Add Test Repository, Dialog: Edit Test Repository

Location

Path of the test repository in the file system

Example: D:\Test Manager\TestRepository_1

_tm_icon____.png

Opens the file manager. There you select the TestRepository.xml file of an existing test repository.

Name

Name of the test repository in CODESYS

The name does not have to match the folder name.

Example: Repository_1

Create

Creates a new test repository

For this purpose, a dialog opens for selecting an empty folder. The file structure of the test repository is created there.

OK

Adds the test repository to the list or applies the changes, and closes the dialog

In the Edit Test Repository dialog, you can change only the name. Location, ..., and Create are not available there.

For more information, see the following: Test Manager