Tab: Tappets
In this graphical editor, the tappet paths are defined. A tappet path defines one or more tappets depending on the master position. At the upper edge of the editor window, a horizontal axis approaches the range of the master positions. The individual tappet paths follow below.
At any time, you can switch between the graphical editor and the alternative tabular editor (Tab: Tappet Table).
![]() | "Track ID" of the tappet path All tappets of a tappet path refer to the same tappet switch (a variable of type BOOL). |
| Use this tool to select the tappets. You can drag the selected tappets to another position. You can modify the switch on/off attribute of a tappet by clicking the relevant end of the Delete the selected tappet by pressing the Del key. |
![]() | Add new tappets with this tool. Click the insertion point in the path. |
The tappet is assigned to a result, if it is passed from the position of the master axis in the positive (increasing master values) or negative direction. | |
X | Position of the tappet |
Positive pass | Switch on/off attribute
|
Negative pass | Switch on/off attribute
|
Tappet Symbol | Positive pass | Negative pass |
|---|---|---|
![]() | No action | No action |
![]() | Switch to ON | No action |
![]() | Switch to OFF | No action |
![]() | No action | Switch to ON |
![]() | No action | Switch to OFF |
![]() | Switch to ON | Switch to OFF |
![]() | Switch to ON | Switch to OFF |
![]() | Switch to OFF | Switch to ON |
![]() | Switch to OFF | Switch to OFF |
![]() | Invert | No action |
![]() | No action | Invert |
![]() | Switch to ON | Invert |
![]() | Invert | Switch to ON |
![]() | Invert | Switch to OFF |
![]() | Switch to OFF | Invert |
![]() | Invert | Invert |
For more information, see: How to define switch points