Tab: Communication Settings

On this tab of the generic device editor, you define the connection between CODESYS and the device on which your application(s) should run. This includes security settings such as encrypted communication and signing.

Tip

If you prefer the classic mode of display for the dialog, then select it in the CODESYS Options in the Device editor category.

You select a gateway and a target device from the list boxes. The possible selections depend on the entries in the Manage Gateways and Manage Favorite Devices dialogs (see the Gateway menu).

You can also specify the target directly with the IP address (example: "192.168.101.109"), the device address (example: [056D]), or the device name (example: MyDevice). After the device is entered, CODESYS searches for the device in the network of the gateway.

Tip

The option of searching by device name requires unique device names in the network.

The solid circle on the lower right corner of the gateway symbol provides information about the connection status:

  • Red: CODESYS cannot establish the connection.

  • Green: The connection is established.

  • Black: The connection status is unknown.

Tip

Some communication protocols allow regular checking of the gateway so that the status cannot be displayed.

Clicking the solid circle of the target device starts a network scan for the device. This works only if the network is not already being scanned.

Scan Network

This button opens the Select Device dialog. It lists all configured gateways with the associated devices. You can select one target device from this list. If the name of the selected device is unique, then the name will be used in the connection settings. Otherwise, the unique device address is applied.

The displayed parameters are defined in the SysTarget component in the runtime system and essentially represent the type plate of the controller. The device name can be changed using the Device → Rename Active Device command.

Option: Hide non-matching devices, filter by Target ID:

standard icon: The display is limited on the devices that have the same target ID as the current device configured in the project.

_cds_icon_option_deactivated.png: All available devices in the network are displayed. Double-clicking the entry of a device, which has a different target system ID than the device configured in the project, opens a dialog box. This dialog box allows you to update the device description of the device in the project to the one matching the selected device. Note: This kind of update is possible only with devices which have different IDs, not for those which only have different versions. The update also requires that the device description is already installed in the repository.

Gateway

This menu includes the following commands:

  • Add New Gateway: Opens the Gateway dialog for defining a new gateway channel

  • Manage Gateways: Opens the Manage Gateways dialog with an overview of all gateways. Here you can add, delete, or edit entries or change their order.

  • Configure Local Gateway: Opens the Gateway Configuration dialog. You can configure the block drivers for the local gateway.

Device

This menu includes the following commands:

  • Options:

    • Add Current Device to Favorites: Adds the currently set device to the list of favorite devices

    • Manage Favorite Devices: Opens the favorites dialog with a list of all preferred devices. In this dialog, you can add or delete entries or change their order. The top device is the default.

    • Confirmed Online Mode:

      standard icon: For security reasons, CODESYS requires a confirmation from you when calling the following online commands: Force Values, Write Values, Multiple Loading, Release Force List, Single Cycle, Start, Stop.

    • Store Communication Settings in Project:

      standard icon: CODESYS saves the communication settings in the project for reuse on the same computer.

      Note: If you use the project on another computer, then you need to reset the active path.

      _cds_icon_option_deactivated.png: CODESYS saves the communication settings in the options of the local installation for reuse on the same computer.

      Note: When using CODESYS SVN, the option should be cleared in order to prevent a lock on the device object.

  • Rename Active Device:

    Opens a dialog for changing the device name

  • Wink Active Device: Devices that support this function react by blinking.

  • Send Echo Service: CODESYS sends five echo services to the controller. These are used to test the network connection, similar to the "ping" function. The services are sent first without a payload and then with a payload. The scope of the payload depends on the communication buffer of the PLC. A message view opens with information about the average echo service delay and the scope of the sent payload.

  • Encrypted Communication:

    standard icon: The communication to this controller is encrypted. A certificate of the controller is required in order to log in to the controller. If the certificate is not available, then an error message opens prompting whether or not the certificate should be displayed and installed.

    If the Enforce encrypted communication option is selected as the Security level in the Security Screen view, then the Encrypted Communication command is disabled here.

  • Change Runtime Security Policy

    Opens the Change Runtime Security Policy dialog for changing the device setting for the encryption of communication

  • Change Runtime Password Policy

    Opens the Change Runtime Password Policy dialog to change the settings for the password policy and the login lock

  • Security Settings: This command is available only if CODESYS Security Agent >= 1.3.0.0 is installed. It opens the Device Security Settings dialog. The current security settings on the connected device are displayed. You can change the settings in the Value column and click OK to write them to the device.

    For example, you will find the settings for device user management and password policy under the CmpUserMgr node (see also further below).

Table 34. Dialog: Change Runtime Security Policy

When you select a new communication policy in this dialog, the configuration in the runtime system is changed.

Communication Settings

Current policy

Shows the currently selected policy for the encryption of communication with the device

New policy

List box for the new policy for encryption

  • No encryption: The device does not support encrypted communication.

  • Optional encryption: The device supports encrypted and unencrypted communication.

  • Enforced encryption: The device supports encrypted communication only.

Code Signing

Current policy

Display of the code signing policy which is currently set in the runtime system

New policy

  • All: All types of application code are accepted.

  • Enforced signing: Only signed application code is accepted (preventing loading an application from untrusted sources).

Device User Management

Current policy

Shows the currently selected policy for user management

New policy

  • Optional user management: It is the responsibility of the user to enable user management on the device or leave the device unprotected.

  • Enforced user management: The user management on the device is enabled and cannot be disabled by the user.

Corresponding entry in the Security Settings: CmpUserMgr UserMgmtEnforce.

Allow anonymous login

standard icon: Specific registered components (for example, OPC UA) can connect to the controller without the providing any credentials. Even if anonymous access to the OPC UA is permitted, the created device user management for the controller remains active.

Corresponding entry in the Security Settings of the device: CmpUserMgr UserMgmt.AllowAnonymous.



Table 35. Dialog: Change Runtime Password Policy

The runtime system password policy configured here is checked in advance in the programming system when the password for a new device user is entered or when the existing password of a device user is changed.

Important

If a limited validity period for a password is configured in the password policy, then the user is prompted to set a new password when logging in after this period has elapsed.

Note: To change a password before it expires, a user currently still requires read permission for the device user management.

Password policy is active

standard icon Password policy is active: The policy is enabled by default. The Password settings can be changed and are used when a password for the device user management is created.

The corresponding entries in the Security Settings of the device are located under the CmpUserMgr node (UserMgmt.PasswordPolicy.<..>). In the configuration file of CODESYS Control, this corresponds to the CmpUserMgr section. Example:

[CmpUserMgr]
SECURITY.UserMgmt.PasswordPolicy=ENABLED
. Password settings
  • Minimum length

    Default setting: 8

  • Number of unique characters

    Default setting: 4

  • Requires lowercase letter

    Default setting: enabled

  • Requires uppercase letter

    Default setting: enabled

  • Requires digit

    Default setting: enabled

  • Requires special character

    Default setting: enabled

  • Must not contain username

    Default setting: enabled

The following rules for the password always apply, even when the rules are partially or completely disabled:

  • The password must not be blank.

  • The password must not contain the user name.

Password expiration is active

standard icon: The Password expiration settings can be modified and are applied at login.

Corresponding entries in the Security Settings of the device: Under the CmpUserMgr node (Password.Expiration.<...>).

Password expiration settings:

  • Scope:

    • ADMINS: The settings apply to users who have administrator permissions.

    • NONADMINS: The settings apply to all users who do not have administrator permissions.

    • ALL: The settings apply to all users.

  • Timeout [days]: Validity period of the password in days. When this time is exceeded, it is no longer possible to log in with the previous password. In this case, you will immediately be prompted to set a new password.

Login lock is active

standard icon: The Login lock settings are applied at login.

Corresponding entries in the Security Settings of the device: Under the CmpUserMgr node (UserLogin.<...>).

. Login lock settings
  • Scope

    • ADMINS: The settings apply to users who have administrator permissions.

    • NONADMINS: The settings apply to all users who do not have administrator permissions.

    • ALL: The settings apply to all users.

  • Maximal Retries: When the number of login attempts specified here is exceeded, the user will be locked out for the amount of time which is specified in the Lock duration field. The user cannot log in again until the lock is removed by an administrator or the lockout time has expired.

  • Lock duration [s]: Lock time (in seconds)

For information about unlocking a locked user, see: Handling of Device User Management



In the CODESYS options, you can activate the classic mode of the Tools → Options dialog in the "Device editor" category).

Select the network path to the controller

Gateway channel for the connection

Select the channel from the lower part of the view.

Table 36. View displaying configured gateway channels and network devices

Left side of view

Tree structure of the configured gateway channels with the connected devices in the local network:

_cds_img_gateway_channels.png

Note: CODESYS saves these entries on the local system, not in the project.

The device entries are preceded by a icon_device.png device symbol. Entries with a target ID that are different from those currently configured in the project are displayed in gray.

Click Scan Network to refresh the list.

Note: If you created the first project on the local system, then the local gateway is listed as an entry in the tree by default. CODESYS starts this gateway automatically on system boot.

The solid circle on the lower right corner of the gateway symbol provides information about the connection status:

  • Red: CODESYS Development System cannot establish the connection.

  • Green: The connection is established: _cds_img_gateway_connected.png.

  • Black: The connection status is unknown.

    Note: Some communication protocols allow regular checking of the gateway so that the status cannot be displayed.

Each of the device entries in the tree consists of a symbol followed by the <device name> [device address]. On the right side of the view, you also see the Target ID, Target Name, Target Type, Target Vendor, and Target Version.

Right side of view

Information about the gateway channel of device selected on the left side of the view

When a gateway channel is selected in the left view, the following information is displayed: Device name, IP address, Port, Driver

When a device is selected in the left view, the following information is displayed (depending of the device): Device name, Device address, Number of channels, Block driver, Serial number, Encrypted communication, Target vendor, Target ID, Target name, Target type, Target version.



Table 37. Filter and sorting functions on the right side of the dialog

Filter

You can reduce the displayed list of devices that have the same Target ID as the current device configured in the project.

Sorting order

You can sort the list by Name or Device Address in alphabetical or ascending order.



Table 38. Command buttons on the right side of the dialog

Set Active Path

The command sets the selected communications channel as active. Double-clicking the entry in the channel tree achieves the same result.

Add Gateway

The command opens the Gateway dialog where you can define a gateway which CODESYS should add to the current configuration.

Add Device

The command opens the Add Device dialog. Here you can manually define a device that is to be inserted under the gateway entry currently selected in the tree. Note the functionality of Scan Network as well.

Scan Network

The command starts a search for available devices in the local network. The configuration tree of the gateway is refreshed accordingly.



Table 39. Commands in the context menu of the gateway tree and device tree in the dialog

Scan for Device by Address

The command searches the network for devices with a unique address as given in the configuration tree. CODESYS displays the detected devices with the given address below the gateway. The search always applies to the devices below the selected gateway or below the selected entry.

Scan for Device by Name

The command searches the network for devices with the same name as given in the configuration tree. Capitalization is ignored. CODESYS displays the detected devices below the gateway with the given name together with its unique device address. The search always applies to the devices below the selected gateway or below the selected entry.

Scan for Device by IP Address

The command searches the network for devices with a unique IP address as given in the configuration tree. CODESYS displays the detected devices with the given address below the gateway together with its name. The search always applies to the devices below the selected gateway or below the selected entry.

Send Echo Service

CODESYS sends five echo services to the controller. These are used to test the network connection, similar to the "ping" function. The services are sent first without a payload and then with a payload. The scope of the payload depends on the communication buffer of the PLC. A message view opens with information about the average echo service delay and the scope of the sent payload.

Delete Selected Device

The command deletes the selected device from the channel tree.

Edit Gateway

The command opens the Gateway dialog for editing the settings for the selected gateway.

Configure the Local Gateway

The command opens a dialog for configuring a local gateway. This provides an alternative to manually editing the Gateway.cfg file.



Table 40. Options in the lower part of the dialog

Don't store communication settings in project

  • standard icon: CODESYS saves the communication settings in the options of the local installation for reuse on the same computer.

    Note: When using CODESYS SVN, the option should be selected in order to prevent a lock on the device object.

  • _cds_icon_option_deactivated.png: CODESYS saves the communication settings in the project for reuse on the same computer.

    Note: If you use the project on another computer, then you need to reset the active path.

Confirmed Online Mode

standard icon: For security reasons, CODESYS requires a confirmation from you when calling the following online commands: Force Values, Write Values, Multiple Loading, Release Force List, Single Cycle, Start, Stop.