Menus in the System Tray
CODESYS Control
Access to the user interface of CODESYS Control Win SL is granted to you by means of the
symbol in the system tray ("Systray") of your PC.
Right-click the
symbol to open a menu with the following commands:
Start PLC: Switches on the PLC. The symbol in the status bar changes to
.Note: If the PLC should automatically be switched on when the system is started, then you have to set the corresponding start option in the properties of the service. For more information, see the help page "Installation and Getting Started".
Stop PLC: Switches off the PLC. The symbol changes to
.Exit PLC Control: Ends the availability of the user menu in the system tray. The symbol is removed, but the PLC continues running. The executable file responsible for the displaying the system tray is
CODESYSControlSysTray.exe. It is located in the installation directory in the subdirectoryGatewayPLCof CODESYS Control Win SL.About: Shows version information about the installed CODESYS Control Win SL
CODESYS Control RTE SL
Access to the user interface of CODESYS Control RTE SL is granted to you by means of the symbol in the system tray ("Systray") of your PC.
Right-click the
symbol to open a menu with the following commands:
Start PLC: Switches on the PLC. The symbol changes to
.Stop PLC: Switches off the PLC. The symbol changes to
.Exit PLC Control: Control of the CODESYS Control RTE SL by means of the system tray is no longer possible. The symbol is removed, but the PLC continues running.
PLC Configuration: Opens the System Configuration dialog. Different tabs include diagnostic information and the configuration settings of CODESYS Control RTE SL.
Remote PLC: Opens the Remote Configuration dialog. By enabling or disabling the Control remote PC, not local option, you determine whether a PLC is used that is on a remote or local PC. Accordingly, the menu commands Start PLC, Stop PLC, and PLC Configuration refer to the local PC or a PC reached on the network. For the remote PC, specify the Target PC address, Port number, and a Timeout value (in ms) for the connection (Remote Timeout [ms]).
About: Shows version information about the installed CODESYS Control RTE SL