View: File Management
Function: The view is used to manage the files on the Automation Server and on the PLC. Files and folders can be downloaded, transferred, and copied from the controller or the Automation Server.
Call:
Server Files | |
Location | Location in the file system of CODESYS Automation Server |
Display of the file directory on the Automation Server | The following information is displayed:
|
| Opens a list box for selecting the information which will be displayed for the files and folders of the CODESYS Automation Server. |
Drag & Drop | Drag & Drop is available for the following copy operations of files and folders.
|
PLC Files | |
Installed PLC | List box for the PLC. Displays all of the PLCs added to the Automation Server When a PLC is selected, the file directory of the PLC is automatically displayed. |
Location | Displays the path of the PLC whose files and folders are currently displayed. Default value: Root directory You can edit the path. Placeholders can be specified in the path (example: Clicking in this field displays the current folder structure. You can navigate between the folders. |
Display of the file directory on the PLC and on the Automation Server | The following information is displayed:
|
| Opens a list box for selecting the information which will be displayed for the files and folders of the PLC. |
Buttons | |
| Refreshes the display with the current state of the PLC and the CODESYS Automation Server. |
| Creates a new folder on the PLC and on the Automation Server. |
| Opens a dialog for renaming the selected file or folder |
| Transfers the PLC files selected in the PLC Files and Server Files area to the download folder of your computer. When multiple files have been selected, they are compressed together in a ZIP file and then stored in the download folder of your computer. |
| Opens the default dialog for selecting the file(s) from the file directory of your computer which should be transferred to the PLC and the CODESYS Automation Server. Then the selected files are displayed in a dialog and the operation can be confirmed or canceled. |
| Opens the Move Files/Folders dialog. Requirement: At least one folder or file must be selected. In this dialog, you select the target folder on the controller and the files and folders of the CODESYS Automation Server which are moved to the controller. In the dialog, you can navigate the file systems of the CODESYS Automation Server and the controller. Click Move to confirm the dialog. |
| Opens the Copy Files/Folders dialog. Requirement: At least one folder or file must be selected. In this dialog, you select the target folder on the controller and the files and folders of the CODESYS Automation Server which are copied to the controller. In the dialog, you can navigate the file systems of the CODESYS Automation Server and the controller. Click Copy to confirm the dialog. |
| Deletes the selected files and directories. |
| Available only for Server Files. Opens the <file or folder name> Permissions dialog. Permissions for server objects can be granted in this dialog. For more information, see the following: Granting Permissions for Access to Server Objects |
| Copies the selected files and folders in the Server Files area to the selected directory of the PLC Files area (i.e., from the Automation Server to the PLC). |
| Opens a wizard whose function is to copy files and folders to the controllers. For a description of the wizard, see the following: Table 26, “Wizard: Copy files/folders to multiple controllers” |
| Copies the selected files and folders in the PLC Files area to the selected directory of the Server Files area (i.e., from the PLC to the Automation Server). |
Step 1: Select PLCs | |
| Search field for controllers |
Name | Name of the PLC |
Status | Status of the controller |
Step 2: Select Files | |
From Server Path | Display of selected files |
| Opens the Select Server File dialog In the dialog, one or more files in the file directory of the server can be selected to be copied. It is also possible to navigate within the file directory of the server. |
To PLC Path | File path on the respective controller |
| Opens the Select PLC Path dialog. In the dialog, you can select a file or a folder from the file directory on the controllers to which the selected files should be copied. It is also possible to navigate within the file directory of the controllers. |
| Inserts a new line. |
Step 3: Overview | |
Overwrite files |
|
List of selected files and folders on the server and controller | |
| Deletes the line. |
Copy Files | The files and folders are copied to the controllers. |