Dialog: Encrypted Communication Quick Setup
Function: Encrypted communication between an Edge Gateway and one or more PLCs can be set up in the dialog. First, the PLC is searched for a qualified certificate for encrypted communication. If no qualified certificate is found, then a certificate is generated on the PLC. Then the certificate is copied to the Edge Gateway so that the Edge Gateway can trust the certificate.
Call:
PLC Details view, Configuration tab, Quick Setup button
Tabular display of the List View,
symbol
Requirements:
The Edge Gateway is running and connected to the CODESYS Automation Server.
The PLC is running below this Edge Gateway.
Installed PLC | Name of the PLC |
Thumbprint | Thumbprint of the certificate |
Status |
Detailed information about the corresponding error is displayed in the tooltips of the status icons. For example, if permissions are missing on the PLC or the PLC is not connected. |
Actions |
|
Prepare Certificates | Searches the PLC for a certificate for encrypted communication. If no corresponding valid certificate is found, then a new certificate is generated and displayed in the table. The |
Enable Encrypted Communication | Copies the qualified valid certificate to the Edge Gateway and enables encrypted communication between the PLC and the Edge Gateway. Prerequisite: A valid certificate is selected in the list. |
For more information, see: Setting Up Encrypted Communication and PLC Details