LConTlC (FB)¶
FUNCTION_BLOCK LConTlC EXTENDS TimingControlledBehaviourModelBase IMPLEMENTS ILConTlC
Base implementation of a PLCopen Level Controlled Behavior Model (see: ILConTlC)
For use, this block should be extended and the specific inputs and outputs must be supplemented.
The output eErrorID of the application-specific enum type ERROR must be added.
- InOut:
Scope
Name
Type
Comment
Input
xEnableBOOLTRUE: Activates the defined operationFALSE: Aborts/resets the defined operationudiTimeLimitUDINTMax. operating time per invocation [µs], 0: No operating time limit
Output
xBusyBOOLTRUE: Operation is runningxErrorBOOLTRUE: Error condition reached
Properties:
ActionController, inherited from TimingControlledBehaviourModelBase
ModelTimeOut, inherited from TimingControlledBehaviourModelBase
Methods:
CleanupAction, inherited from TimingControlledBehaviourModelBase
CyclicAction, inherited from TimingControlledBehaviourModelBase
ExitAction, inherited from TimingControlledBehaviourModelBase
GetConfiguration, inherited from TimingControlledBehaviourModelBase
GetConfiguration2, inherited from TimingControlledBehaviourModelBase
ResetAction, inherited from TimingControlledBehaviourModelBase
StartAction, inherited from TimingControlledBehaviourModelBase
Structure: