SA0043:仅在一个 POU 中使用全局变量
仅在单个 POU 中检测全局变量的使用
理由:仅在一个位置使用的全局变量也只能在该位置声明。
重要性:中等
PLCopen规则:CP26
例 52. 例子
VAR_GLOBAL
g_xVar AT %QX0.0 : BOOL ;
g_iTest AT %QW1 : INT ;
g_wTest AT %QW2 : WORD;
END_VARPROGRAM prog1
VAR
iCondition : INT;
bTemp : BOOL;
END_VAR
iCondition := iCondition + INT#1;
IF iCondition < INT#0 THEN
bTemp := g_xVar; // SA0043 - g_xVar only read in this POU
ELSIF iCondition = INT#0 THEN
bTemp := g_xVar; // SA0043 - g_xVar only read in this POU
ELSE
bTemp := g_xVar; // SA0043 - g_xVar only read in this POU
g_wTest := WORD#4; // g_WTest used also in prog2 -> OK
END_IFPROGRAM prog2
VAR
iCondition : INT;
END_VAR
iCondition := iCondition + INT#1;
CASE iCondition OF
INT#1:
g_iTest := WORD_TO_INT(g_wTest); // SA0043 - g_iTest only written in this POU
INT#2:
g_iTest := INT#2; // SA0043 - g_iTest only written in this POU
ELSE
g_iTest := INT#3; // SA0043 - g_iTest only written in this POU
END_CASE输出在 留言 看法:
SA0043:全局变量“g_xVar”仅在“prog1”中使用
SA0043:全局变量“g_iTest”仅在“prog2”中使用