AXIS_REF_CAN_Jat (FB)¶
FUNCTION_BLOCK AXIS_REF_CAN_Jat EXTENDS AXIS_REF_CAN_DS402_IP
Supported drive models¶
ECOSTEP 100, ECOSTEP 200, ECOVARIO 114, ECOVARIO 214, ECOVARIO 414, ECOMiniDual
Features¶
| Feature | Supported | Description | |
| Enabling/Disabling | bRegulatorOn |   | Controls the power stage of the drive, but resetting this control flag will make the drive stop before unpowering. | 
| bDriveStart |   | Executes a QuickStop if not set. | |
| Acknowledging Errors |   | Drive errors can be acknowledged. | |
| Mechanical Brakes | 
 |   | Mode not supported | 
| 
 |   | Mode not supported | |
| 
 |   | Mode not supported | |
| Hardware Limit Switches |   | Supported | |
| Controller Modes | Position |   | Supported | 
| Velocity |   | Mode not supported | |
| Torque |   | Mode not supported | |
| Homing (drive controlled) |   | Supported Must be configured in the drive before. | |
| Capturing/Latching |   | Not Supported | |
| External Halt |   | Not Supported | |
Notes for Commisioning¶
Parameters¶
| ID | Name | Data type | Description | 
| 10000 | errorOnInternalLimit | BOOL | If TRUE, the axis switches to errorstop if an internal limit of the drive is reached. An internal limit is a limit other than limit switches that is indicated by bit 11 of the status word, for example an i²t error. Default: FALSE | 
Initializations¶
| Object ID | Value | Comment | 
| 16#1014:0 | 16#80000080+DriveID | EMCY deaktivieren | 
| 16#2F88:1 | Cycle time in ms | Cycle time for interpolation, not for ECOSTEP | 
| 16#2F88:10 | SyncPhase | Not for ECOSTEOP | 
| 16#605A: | 6 | Quickstop Option Code | 
- InOut:
- Scope - Name - Type - Initial - Comment - Inherited from - Input - wAxisStructID- WORD- 16#FE12 - AXIS_REF_SM3 - nAxisState- SMC_AXIS_STATE- power_off - State of the axis according to the - PLCopenstate diagram:- 0: - power_off
- 1: - errorstop
- 2: - stopping
- 3: - standstill
- 4: - discrete_motion
- 5: - continuous_motion
- 6: - synchronized_motion
- 7: - homing
 - Parameter number: 1000 - AXIS_REF_SM3 - bRegulatorOn- BOOL- FALSE - Parameter number: 1010 - AXIS_REF_SM3 - bDriveStart- BOOL- FALSE - Parameter number: 1011 - AXIS_REF_SM3 - bCommunication- BOOL- FALSE - TRUE: Communication OKParameter number: 1012- AXIS_REF_SM3 - wCommunicationState- WORD- 16#FFFF - Parameter number: 1013 - AXIS_REF_SM3 - uiDriveInterfaceError- UINTDrive interface error numberParameter number: 1014- AXIS_REF_SM3 - bRegulatorRealState- BOOL- FALSE - Parameter number: 1015 - AXIS_REF_SM3 - bDriveStartRealState- BOOL- FALSE - Parameter number: 1016 - AXIS_REF_SM3 - wDriveId- WORD- 0 - Parameter number: 1021 - AXIS_REF_SM3 - iOwner- INT- 0 - Parameter number: 1022 - AXIS_REF_SM3 - fCycleTimeSpent- LREAL- Parameter number: 1024 - AXIS_REF_SM3 - fTaskCycle- LREAL- 0.005 - Parameter number: 1025 - AXIS_REF_SM3 - bError- BOOL- FALSE - Parameter number: 1030 - AXIS_REF_SM3 - dwErrorID- DWORD- 0 - Drive specific error identifier, parameter number: 1031 - AXIS_REF_SM3 - bErrorAckn- BOOL- FALSE - Parameter number: 1032 - AXIS_REF_SM3 - bDisableErrorLogging- BOOL- FALSE - Parameter number: 1036 - AXIS_REF_SM3 - fbeFBError- ARRAY [0..g_SMC_NUMBER_FB_ERRORS] OF SMC_FBERROR - Parameter number: 1035 - AXIS_REF_SM3 - dwRatioTechUnitsDenom- DWORD- 1 - Parameter number 1051 - AXIS_REF_SM3 - iRatioTechUnitsNum- DINT- 1 - Parameter number 1052 - AXIS_REF_SM3 - nDirection- MC_Direction- positive - Parameter number 1053 - AXIS_REF_SM3 - fScalefactor- LREAL- 1 - Parameter number 1054 - AXIS_REF_SM3 - fFactorVel- LREAL- 1 - Parameter number 1055 - AXIS_REF_SM3 - fFactorAcc- LREAL- 1 - Parameter number: 1056 - AXIS_REF_SM3 - fFactorTor- LREAL- 1 - Parameter number: 1057 - AXIS_REF_SM3 - fFactorJerk- LREAL- 1 Factor jerkParameter number: 1058- AXIS_REF_SM3 - fFactorCur- LREAL- 1 - Parameter number: 1059 - AXIS_REF_SM3 - fFactorReference- LREAL- 1 - The factor the home offset (fReference, parameter 1211) is multiplied by after conversion to increments. When converting from increments, the received value in increments is divided by the factor. Drivers can set this to -1 to invert the sign of the home offset. - AXIS_REF_SM3 - iMovementType- INT- SMC_AXIS_TYPE.finite - Parameter number: 1060 - AXIS_REF_SM3 - fPositionPeriod- LREAL- 1000 - Parameter number: 1061 - AXIS_REF_SM3 - eRampType- SMC_RAMPTYPE- trapez - Parameter number: 1062 - AXIS_REF_SM3 - motorType- SMC_MOTOR_TYPE- Parameter number: 5007 - AXIS_REF_SM3 - byControllerMode- BYTE- SMC_position - Parameter number: 1091 - AXIS_REF_SM3 - byRealControllerMode- BYTE- SMC_position - Parameter number: 1092 - AXIS_REF_SM3 - fSetPosition- LREAL- 0 - Parameter number: 1100, 1 - AXIS_REF_SM3 - fActPosition- LREAL- 0 - Parameter number: 1101 - AXIS_REF_SM3 - fAimPosition- LREAL- 0 - Parameter number: 1105 - AXIS_REF_SM3 - fSavePosition- LREAL- 0 - Parameter number: 1107 - AXIS_REF_SM3 - fSetVelocity- LREAL- 0 - Parameter number: 1110, 11 - AXIS_REF_SM3 - fActVelocity- LREAL- 0 - Parameter number: 1111, 10 - AXIS_REF_SM3 - fMaxVelocity- LREAL- 0 Maximum velocity of the drive (remote parameter) in [u/s]Parameter number: 1112,9- AXIS_REF_SM3 - fSWMaxVelocity- LREAL- 0 Maximum velocity (software limit) in [u/s]Parameter number: 1113- AXIS_REF_SM3 - bConstantVelocity- BOOL- FALSE - Parameter number: 1115 - AXIS_REF_SM3 - fSaveVelocity- LREAL- 0 - Parameter number: 1117 - AXIS_REF_SM3 - fSetAcceleration- LREAL- 0 - Parameter number: 1120 - AXIS_REF_SM3 - fActAcceleration- LREAL- 0 - Parameter number: 1121 - AXIS_REF_SM3 - fMaxAcceleration- LREAL- 0 Maximum acceleration of the drive (remote parameter) in [u/s²]Parameter number: 1122, 13- AXIS_REF_SM3 - fSWMaxAcceleration- LREAL- 0 Maximum acceleration (software limit) in [u/s²]Parameter number: 1123- AXIS_REF_SM3 - bAccelerating- BOOL- FALSE - Parameter number: 1125 - AXIS_REF_SM3 - fSaveAcceleration- LREAL- 0 - Parameter number: 1127 - AXIS_REF_SM3 - fMaxDeceleration- LREAL- 0 Maximum deceleration of the drive (remote parameter) in [u/s²]Parameter number: 1132, 15- AXIS_REF_SM3 - fSWMaxDeceleration- LREAL- 0 Maximum deceleration (software limit) in [u/s²]Parameter number: 1133- AXIS_REF_SM3 - bDecelerating- BOOL- FALSE - Parameter number: 1135 - AXIS_REF_SM3 - fSaveDeceleration- LREAL- 0 - Parameter number: 1137 - AXIS_REF_SM3 - fSetJerk- LREAL- 0 - Parameter number: 1140 - AXIS_REF_SM3 - fActJerk- LREAL- 0 - Parameter number: 1141 - AXIS_REF_SM3 - fMaxJerk- LREAL- 0 - Maximum jerk of the drive (remote parameter) in [u/s³] Parameter number: 1142, 16 - AXIS_REF_SM3 - fSWMaxJerk- LREAL- 0 Maximum jerk (software limit) in [u/s³]Parameter number: 1143- AXIS_REF_SM3 - fRampJerk- LREAL- 100000 - Maximum Jerk, special value for sin² ramp type in [u/s³] Parameter number: 1144 - AXIS_REF_SM3 - fSaveJerk- LREAL- 0 - Parameter number: 1147 - AXIS_REF_SM3 - fSetCurrent- LREAL- 0 - Parameter number: 1150 - AXIS_REF_SM3 - fActCurrent- LREAL- 0 - Parameter number: 1151 - AXIS_REF_SM3 - fMaxCurrent- LREAL- 100 Maximum current in [A]Parameter number: 1152- AXIS_REF_SM3 - fSWMaxCurrent- LREAL- 0 Maximum user defined current in [A]Parameter number: 1153- AXIS_REF_SM3 - fSetTorque- LREAL- 0 - The set torque in [Nm] or [N] (linear) at the gearbox output. Parameter number: 1160 - AXIS_REF_SM3 - fActTorque- LREAL- 0 Actual torque in [Nm] or [N] (linear) at the gearbox output.Parameter number: 1161- AXIS_REF_SM3 - fMaxTorque- LREAL- 0 - The maximum torque in [Nm] or [N] (linear) at the gearbox output. Parameter number: 1162 - AXIS_REF_SM3 - fSWMaxTorque- LREAL- FPU.GetLRealSpecialVal(FPU.ESpecial_FP_Value.PosInf) - The maximum torque (software limit) in [Nm] or [N] (linear) at the gearbox output. Parameter number: 1163 - AXIS_REF_SM3 - fSWLimitPositive- LREAL- 0 Position limit in positive direction in [u]Parameter number: 1200, 2- AXIS_REF_SM3 - fSWLimitNegative- LREAL- 0 Position limit in negative direction in [u]Parameter number: 1201, 3- AXIS_REF_SM3 - usiSWEndSwitchState- USINT- 0 - Parameter number: 1204 - AXIS_REF_SM3 - bSWLimitEnable- BOOL- FALSE - Parameter number: 1205 - AXIS_REF_SM3 - bHWLimitEnable- BOOL- TRUE - Parameter number: 1206 - AXIS_REF_SM3 - bStartReference- BOOL- FALSE - Parameter number: 1210 - AXIS_REF_SM3 - fReference- LREAL- 0 - Parameter number: 1211 - AXIS_REF_SM3 - bStartReferenceRealState- BOOL- FALSE - Parameter number: 1212 - AXIS_REF_SM3 - fOffsetPosition- LREAL- 0 - Parameter number: 1215 - AXIS_REF_SM3 - dwPosOffsetForResiduals- DWORD- 0 - Parameter number: 1230 - AXIS_REF_SM3 - dwOneTurn- DWORD- 0 - Parameter number: 1231 - AXIS_REF_SM3 - dwLastPosition- DWORD- 0 - Parameter number: 1232 - AXIS_REF_SM3 - bySwitchingState- SMC_SWITCHING_STATE- SMC_ST_INITIALIZING - Parameter number: 1233 - AXIS_REF_SM3 - iRestNumerator- DINT- 0 - Parameter number: 1234 - AXIS_REF_SM3 - iTurn- INT- 0 - Parameter number: 1235 - AXIS_REF_SM3 - dwActPosition- DWORD- 0 - Parameter number: 1238 - AXIS_REF_SM3 - usiBusBitWidth- USINT- 32 - The bus bit depth. This is the number of bits used to send the actual and set position from and to the drive. Between 1 and 32. - AXIS_REF_SM3 - dwBusModuloMask- DWORD- 16#FFFFFFFF The value (2^k - 1) where k is the bus bit depth.- AXIS_REF_SM3 - eBrakeControl- SMC3_BrakeSetState- SMC_BRAKE_AUTO - Parameter number: 1017 - AXIS_REF_SM3 - bBrakeClosedRealState- BOOL- FALSE - Parameter number: 1018 - AXIS_REF_SM3 - bOldError- BOOL- Parameter number: 1033 - AXIS_REF_SM3 - bVirtual- BOOL- TRUE: Virtual drive. Parameter number: 1040- AXIS_REF_SM3 - bLogical- BOOL- Parameter number: 1041 - AXIS_REF_SM3 - fSetActTimeLagCycles- LREAL- 3 - The dead time in cycles between the fActPosition received in this bus task cycle, and the fSetPosition at the beginning OF THIS bus task cycle. Parameter number: 1070 - AXIS_REF_SM3 - diSetPosition- DINT- 0 - Parameter number: 1108 - AXIS_REF_SM3 - diActPosition- DINT- 0 - Parameter number: 1109 - AXIS_REF_SM3 - diSetVelocity- DINT- 0 - Parameter number: 1118 - AXIS_REF_SM3 - diActVelocity- DINT- 0 - Parameter number: 1119 - AXIS_REF_SM3 - diSetAcceleration- DINT- 0 - Parameter number: 1128 - AXIS_REF_SM3 - diActAcceleration- DINT- 0 - Parameter number: 1129 - AXIS_REF_SM3 - diSetCurrent- DINT- 0 - Parameter number: 1158 - AXIS_REF_SM3 - diActCurrent- DINT- 0 - Parameter number: 1159 - AXIS_REF_SM3 - diSetTorque- DINT- 0 - Parameter number: 1168 - AXIS_REF_SM3 - diActTorque- DINT- 0 - Parameter number: 1169 - AXIS_REF_SM3 - fSWLimitDeceleration- LREAL- 0 Deceleration in [u/s²] with which the system will brake in case of a software limit.Parameter number: 1203- AXIS_REF_SM3 - xWaitForHaltWhenStopInterruptsHome- BOOL- AXIS_REF_SM3 - fSWErrorMaxDistance- LREAL- 0 Distance in which the drive has to reach standstill after an error has occurred.Parameter number: 1250- AXIS_REF_SM3 - eCheckPositionLag- SMC3_CheckPositionLagMode- 0 - Parameter number: 1207 - AXIS_REF_SM3 - fMaxPositionLag- LREAL- Parameter number: 1208 - AXIS_REF_SM3 - bPositionLagActive- BOOL- Parameter number: 1209 - AXIS_REF_SM3 - bModuloDoneByDrive- BOOL- Parameter number: 1242 - AXIS_REF_SM3 - diFollowingError- DINT- Parameter number: 1243 - AXIS_REF_SM3 - fFollowingError- LREAL- Parameter number: 1244 - AXIS_REF_SM3 - aCaptDesc- ARRAY [0..7] OF SMC3_CaptureDescription - Parameter number: 1400 - AXIS_REF_SM3 - xPersistentDataLoaded- BOOL- FALSE - AXIS_REF_SM3 - strDriveInterfaceError- STRING(255)- AXIS_REF_SM3 - adatAcyclic- ARRAY [1..SMC3_gc_usiNumberAcyclicChannels] OF SMC3_DriveAcyclicTel - AXIS_REF_SM3 - nAbortCounter- UDINT- Internal: counts the number of aborts. This counter simply wraps to 0 when exceeding 2^32-1, so use accordingly. Increased in method SetOwner(). - AXIS_REF_SM3 - vMinRequiredVersion- VERSION- The minimum version of SM3_Basic that the driver requires. - AXIS_REF_SM3 - bAvoidReversalOnHaltStop- BOOL- Parameter number: 1260 - AXIS_REF_SM3 - bConsiderLimitsOfAbortedMotionOnHaltStop- BOOL- Parameter number: 1270 - AXIS_REF_SM3 - bUpdateIOsInStop- BOOL- Update the IOs if the application is stopped. Parameter number 1280 - AXIS_REF_SM3 - bAutoRestart- BOOL- TRUE - If TRUE, an implict |SMC3_ReinitDrive| is executed after the communication to the drive is established again after a communication loss (e.g. fieldbus slave no longer operational). If FALSE, an explicit call to |SMC3_ReinitDrive| is required after communication has been established again. (This is the behavior of SoftMotion versions before 4.18.0.0.) Default is TRUE if not set by the device parameter, i.e. the drive device can override the default. Parameter number 1281 - AXIS_REF_SM3 - overrideFactors- SMRB.DynFactors- STRUCT(fVel := 1, fAcc := 1, fJerk := 1, fTorque := 1) - AXIS_REF_SM3 - m_superimposed- SMC_SuperimposedData- Internal: information of superimposed movements - AXIS_REF_SM3 - Output - strDriver- STRING(16)- AXIS_REF_SM3 - dwDriverVersion- DWORD- AXIS_REF_SM3 - Input - out- SMC3_CIA_DSP402_SpecificOutputs- AXIS_REF_CAN_DS402_IP - eType- SMC_JATUnknown