SMC_TRAFOF_Gantry2 (FB)ΒΆ

FUNCTION_BLOCK SMC_TRAFOF_Gantry2

Forward transformation for two-dimensional gantries (X/Y). Each instance of SMC_TRAFOF_GANTRY2 can be connected to a visualization template named SMC_VISU_Gantry2 .

Note

For detailed information on transformations see Overview to SM_Trafo_POUs.

InOut:

Scope

Name

Type

Comment

Inout

DriveX

AXIS_REF_SM3

Reference to x-axis

DriveY

AXIS_REF_SM3

Reference to y-axis

Input

dOffsetX

LREAL

Offset x-position. Equivalent to SMC_TRAFO_Gantry2

dOffsetY

LREAL

Offset y-position. Equivalent to SMC_TRAFO_Gantry2

minX

LREAL

Lower bound of move range in x-direction (for visualization purpose)

maxX

LREAL

Upper bound of move range in x-direction (for visualization purpose)

minY

LREAL

Lower bound of move range in y-direction (for visualization purpose)

maxY

LREAL

Upper bound of move range in y-direction (for visualization purpose)

Output

dx

LREAL

X-position

dy

LREAL

Y-position

dnx

LREAL

Normed x-position (with value in [0,1])

dny

LREAL

Normed y-position (with value in [0,1])

ratio

LREAL

Ratio x-interval / y-interval

dnOffsetX

LREAL

X-offset for visualization

dnOffsetY

LREAL

Y-offset for visualization