WebClient (FB)ΒΆ
FUNCTION_BLOCK WebClient
Function block to send http and https requests.
- InOut:
- Scope - Name - Type - Initial - Comment - Input - xExecute- BOOL- Rising edge: Send request - udiTimeOut- UDINT- Timeout in micro seconds - sURL- STRING(1024)- URL of the web server - eRequestType- REQUEST_TYPE.GET - Type of the request: POST or GET - eContentType- CONTENT_TYPE.APPLICATION_FORM - HTTP Content-Type of the request - pwsAdditionalHeader- POINTER TO WSTRING - Additional HTTP header - pwsPostValue- POINTER TO WSTRING - Post parameter - xCloseConnection- BOOL- FALSE - Close the connection after each request. - hCert- RTS_IEC_HANDLE- RTS_INVALID_HANDLE - Handle to a certificate (optional) - itfTLSContext- NBS.ITLSContext- 0 - Encapsulates all the data neccecray to handle encrypted tcp connections - Static initialization, as shown in the following code snippet. - VAR commonName : STRING := 'MyRrasPi'; ciCertInfo : NBS.CERT_INFO := (psInfo:=ADR(commonName), udiSize:=LEN(commonName)); myTLSContext : NBS.TLSContext := ( ePurpose:=NBS.PURPOSE.CLIENT_SIDE, sUseCaseName:='NBSTest', sTLSVersion:='1.3', ciCertInfo:=ciCertInfo, udiVerificationMode:=2 ); END_VAR - itfAsyncProperty- NBS.IAsyncProperty- 0 - Runs the connect process in a own background task, usage see library Net Base Services. - Output - xDone- BOOL- xBusy- BOOL- xError- BOOL- eError- Current error state - httpResult- The result of the request 
