CODESYS GmbH
  • Deutsch
  • English
  • Français
  • Español
  • Italiano
  • Русский
  • 日本語
  • 中文
Menu
Search
  • Deutsch
  • English
  • Français
  • Español
  • Italiano
  • Русский
  • 日本語
  • 中文
  • VisuTrendStorageAccess
    • Access to trend storage
      • IRowIdIterator (Interface)
        • GetNextRowId (Method)
        • GetSavedState (Method)
        • HasNextRowId (Method)
        • HasSavedState (Method)
        • Initialize (Method)
        • SaveState (Method)
      • ITrendRootPageManager2 (Interface)
        • DetermineRootPagesTimeout (Method)
      • ITrendStorageAccessReadOperator (Folder)
        • AfterReadingData (Method)
        • AfterReadingVariableValuesOfRow (Method)
        • BeforeReadingData (Method)
        • BeforeReadingVariableValuesOfRow (Method)
        • DoContinueReading (Method)
        • FinalizeReading (Method)
        • FirstDataRowOfNewConfigurationReached (Method)
        • InitializeReading (Method)
        • IsVariableToRead (Method)
        • ProcessPacketFlags (Method)
        • ProcessTimestamp (Method)
        • ProcessValue (Method)
        • prvTblTrendConfigurationGetConfig
        • prvTblTrendConfigurationGetDiagramConfig
      • ITrendStorageAccessReadOperator2 (Folder)
        • CurveFillingAlphaRead (Method)
        • CurveFillingColorRead (Method)
        • CurveFillingTypeRead (Method)
        • CurveTypeRead (Method)
        • GradientAngleRead (Method)
        • GradientBrightnessRead (Method)
        • GradientCenterXRead (Method)
        • GradientCenterYRead (Method)
        • GradientColor1Read (Method)
        • GradientColor2Read (Method)
        • GradientColorBrightnessRead (Method)
        • GradientTranspColor1Read (Method)
        • GradientTranspColor2Read (Method)
        • GradientTypeRead (Method)
        • GradientUseTwoColorsRead (Method)
      • TrendFbDatabaseAccessErrorHandler (FunctionBlock)
        • ErrorHandling (Method)
        • IsDatabaseAccessEnabled (Method)
        • SQLiteErrorHandling (Method)
        • private
      • TrendFbTrendStorageWriterReader (FunctionBlock)
        • GetMinMaxTimestampsFromBuffer (Method)
        • ITrendStorageWriterBufferClient
        • Initialize (Method)
        • Read (Method)
        • ShrinkMemory (Method)
      • TrendFctCursorSearchFirstRow (Function)
      • TrendFctGetTimestamp (Function)
    • ETrendStorageGraphType (Enum)
    • ETrendStoragePenStyle (Enum)
    • ETrendStorageReaderErrors (Enum)
    • ETrendStorageReaderStep (Enum)
    • GlobalInstances (GVL)
    • ITrendStorageReaderConsumer (Interface)
      • ErrorOccurred (Method)
      • ReadingDataCompleted (Method)
      • TimestampRead (Method)
      • ValueRead (Method)
      • VariableConfigurationRead (Method)
    • ITrendStorageWriterListener (Interface)
      • DataWritten (Method)
    • Service
      • SwapDword (Function)
      • SwapLword (Function)
      • SwapWord (Function)
      • TrendStorageCache
        • TrendStorageCacheItemData (FunctionBlock)
    • TrendStorageConvertFromTimestamp (Function)
    • TrendStorageConvertToTimestamp (Function)
    • TrendStorageReader (FunctionBlock)
      • AddTrendStorageWriterListener (Method)
      • ContinueReading (Method)
      • GetMinMaxTimestamps (Method)
      • ITrendStorageAccessReadOperator
        • DoContinueReading (Method)
        • prvTblTrendConfigurationGetConfig
      • ITrendStorageAccessReadOperator2
        • CurveFillingAlphaRead (Method)
        • CurveFillingColorRead (Method)
        • CurveFillingTypeRead (Method)
        • CurveTypeRead (Method)
        • GradientAngleRead (Method)
        • GradientBrightnessRead (Method)
        • GradientCenterXRead (Method)
        • GradientCenterYRead (Method)
        • GradientColor1Read (Method)
        • GradientColor2Read (Method)
        • GradientColorBrightnessRead (Method)
        • GradientTranspColor1Read (Method)
        • GradientTranspColor2Read (Method)
        • GradientTypeRead (Method)
        • GradientUseTwoColorsRead (Method)
      • Initialize (Method)
      • Read (Method)
      • RemoveTrendStorageWriterListener (Method)
    • TrendStorageReaderGlobals (GVL)
    • TrendStorageReaderValueConverter (FunctionBlock)
      • ConvertToLREAL (Method)
      • ConvertToREAL (Method)
      • ConvertToString (Method)
      • SetVariableConfiguration (Method)
    • TrendStorageVariableDescription (Struct)
  • File and Project Information
  • Library Reference
    • 3S Storage
      • Library Identification
      • Library Properties
    • Base Interfaces
      • Library Identification
      • Library Properties
    • CAA FB Factory
      • Library Identification
      • Library Properties
    • CAA Storage
      • Library Identification
      • Library Properties
    • CAA Types Extern
      • Library Identification
      • Library Properties
    • CmpApp
      • Library Identification
      • Library Properties
    • CmpBinTagUtilIec
      • Library Identification
      • Library Properties
    • CmpErrors2 Interfaces
      • Library Identification
      • Library Properties
    • CmpEventMgr
      • Library Identification
      • Library Properties
    • CmpIecTask
      • Library Identification
      • Library Properties
    • CmpLog
      • Library Identification
      • Library Properties
    • CmpSrv
      • Library Identification
      • Library Properties
    • CmpTraceMgr
      • Library Identification
      • Library Properties
    • Collections
      • Library Identification
      • Library Properties
    • Element Collections
      • Library Identification
      • Library Properties
    • FloatingPointUtils
      • Library Identification
      • Library Properties
    • Rts Service Handler
      • Library Identification
      • Library Properties
    • Standard
      • Library Identification
      • Library Properties
    • Standard64
      • Library Identification
      • Library Properties
    • StringUtils
      • Library Identification
      • Library Properties
    • SysFile
      • Library Identification
      • Library Properties
    • SysMem
      • Library Identification
      • Library Properties
    • SysSem
      • Library Identification
      • Library Properties
    • SysTask
      • Library Identification
      • Library Properties
    • SysTimeCore
      • Library Identification
      • Library Properties
    • SysTimeRtc
      • Library Identification
      • Library Properties
    • SysTypes2 Interfaces
      • Library Identification
      • Library Properties
    • Trace Mgr Utils
      • Library Identification
      • Library Properties
    • Trace Mgr2 Interfaces
      • Library Identification
      • Library Properties
VisuTrendStorageAccess
  • Docs »
  • Index

Index

E | I | S | T

E

  • ETrendStorageGraphType
  • ETrendStoragePenStyle
  • ETrendStorageReaderErrors
  • ETrendStorageReaderStep

I

  • IRowIdIterator
  • ITrendRootPageManager2
  • ITrendStorageAccessReadOperator
  • ITrendStorageAccessReadOperator2
  • ITrendStorageReaderConsumer
  • ITrendStorageWriterListener

S

  • SwapDword
  • SwapLword
  • SwapWord

T

  • TrendFbDatabaseAccessErrorHandler
  • TrendFbTrendStorageWriterReader
  • TrendFctCursorSearchFirstRow
  • TrendFctGetTimestamp
  • TrendStorageCacheItemData
  • TrendStorageConvertFromTimestamp
  • TrendStorageConvertToTimestamp
  • TrendStorageReader
  • TrendStorageReaderValueConverter
  • TrendStorageVariableDescription
top

CODESYS Group | We software Automation. to software
['sɒftwɛər]
transitive verb
__softwared/softwaring
: to develop software
// to software automation: to develop software for automation purposes

The CODESYS Group is the manufacturer of CODESYS, the leading hardware-independent IEC 61131-3 automation software for developing and engineering controller applications.
CODESYS® is a registered trademark.

CODESYS GmbH
A member of the CODESYS Group
Memminger Straße 151, 87439 Kempten
Germany
Tel.: +49-831-54031-0
info@codesys.com
  • Legal Notice
  • Privacy Policy
LinkedIn Youtube RSS Downloads Login CODESYS Store
© 2022 CODESYS GmbH | A member of the CODESYS Group