ITrendStorageAccessReadOperator2 (ITF)ΒΆ
INTERFACE ITrendStorageAccessReadOperator2 EXTENDS ITrendStorageAccessReadOperator
This interface is an extension of ITrendStorageAccessReadOperator, that provide functionality for the method Read of function block TrendFbTrendStorageAccess. Is contains a set of callback methods.
Methods:
ActivateMaxWarningRead, inherited from ITrendStorageAccessReadOperator
ActivateMinWarningRead, inherited from ITrendStorageAccessReadOperator
AfterReadingData, inherited from ITrendStorageAccessReadOperator
AfterReadingVariableConfiguration, inherited from ITrendStorageAccessReadOperator
AfterReadingVariableValuesOfRow, inherited from ITrendStorageAccessReadOperator
BeforeReadingData, inherited from ITrendStorageAccessReadOperator
BeforeReadingVariableConfiguration, inherited from ITrendStorageAccessReadOperator
BeforeReadingVariableValuesOfRow, inherited from ITrendStorageAccessReadOperator
ColIDRead, inherited from ITrendStorageAccessReadOperator
DescriptionTextIDRead, inherited from ITrendStorageAccessReadOperator
DisplayVariableNameRead, inherited from ITrendStorageAccessReadOperator
DoContinueReading, inherited from ITrendStorageAccessReadOperator
FinalizeReading, inherited from ITrendStorageAccessReadOperator
FirstDataRowOfNewConfigurationReached, inherited from ITrendStorageAccessReadOperator
GraphColorRead, inherited from ITrendStorageAccessReadOperator
GraphTypeRead, inherited from ITrendStorageAccessReadOperator
InitializeReading, inherited from ITrendStorageAccessReadOperator
IsVariableToRead, inherited from ITrendStorageAccessReadOperator
LineStyleRead, inherited from ITrendStorageAccessReadOperator
LineWidthRead, inherited from ITrendStorageAccessReadOperator
MaxWarningColorRead, inherited from ITrendStorageAccessReadOperator
MaxWarningThresholdRead, inherited from ITrendStorageAccessReadOperator
MinWarningColorRead, inherited from ITrendStorageAccessReadOperator
MinWarningThresholdRead, inherited from ITrendStorageAccessReadOperator
ProcessPacketFlags, inherited from ITrendStorageAccessReadOperator
ProcessTimestamp, inherited from ITrendStorageAccessReadOperator
ProcessValue, inherited from ITrendStorageAccessReadOperator
VariableNameRead, inherited from ITrendStorageAccessReadOperator
VariableTypeRead, inherited from ITrendStorageAccessReadOperator
YAxisDescriptionRead, inherited from ITrendStorageAccessReadOperator
Structure:
- CurveFillingAlphaRead (Method)
- CurveFillingColorRead (Method)
- CurveFillingTypeRead (Method)
- CurveTypeRead (Method)
- GradientAngleRead (Method)
- GradientBrightnessRead (Method)
- GradientCenterXRead (Method)
- GradientCenterYRead (Method)
- GradientColor1Read (Method)
- GradientColor2Read (Method)
- GradientColorBrightnessRead (Method)
- GradientTranspColor1Read (Method)
- GradientTranspColor2Read (Method)
- GradientTypeRead (Method)
- GradientUseTwoColorsRead (Method)