GVL_CONSTANT (GVL)

Attributes:
qualified_only
InOut:

Scope

Name

Type

Initial

Comment

Constant

CLIENT_NAME

STRING

‘VisuRedundCLIENT’

Client name

SERVER_NAME

STRING

‘VisuRedundSERVER’

Server name

LIB_NAME

STRING

‘VisuRedund’

Library name

CLIENT_SIDE

STRING

‘(Client)’

Used in log

SERVER_SIDE

STRING

‘(Server)’

used in log

VISUOPQUEUE

STRING

‘(VisuOpQueue)’

used in log

PERSISTENCE

STRING

‘(Persistence)’

used in log

GENERAL

STRING

‘(Visu_redund)’

used in log

LINE_TCP

INT

0

Use TCP

LINE_MAX

INT

LINE_TCP

LINE_UDP : INT := 1; // Use UDP (future implementation ?)

MAX_CLIENT_HANDLING

INT

20

Max client to handle in one shot

MAX_VARCHG_HANDLING

INT

20

Max variable change in one shot

INVALID_EXTERNAL_ID

DWORD

16#FFFFFFFF

CMD_PEER_IPV4

DWORD

(VisuElemBase.Visu_Paint_Cmds_Globals.VISU_CMD_REDUNDANCY_START + 0)

Commands used in the “paint buffer” to send parameters to web client

CMD_TICKET

DWORD

(VisuElemBase.Visu_Paint_Cmds_Globals.VISU_CMD_REDUNDANCY_START + 1)

CMD_REDUND_ID

DWORD

(VisuElemBase.Visu_Paint_Cmds_Globals.VISU_CMD_REDUNDANCY_START + 2)

CMD_SO_HOSTNAMES

DWORD

(VisuElemBase.Visu_Paint_Cmds_Globals.VISU_CMD_REDUNDANCY_START + 3)

INIT_ACTIVITIES_DONE

TIME

TIME#3s0ms

INIT_ACTIVITIES_DONE_MAX

TIME

TIME#10s0ms

TAG_SIZE

INT

3

THUMB_SIZE

INT

20

THUMB_STRING_SIZE

INT

(THUMB_SIZE * 2)

SIWTCHOVER_HOSTNAMES_MAX_COUNT

INT

10

Configuration for multiple configured Visu Switchover adresses

SECT_NAME

STRING

‘VisuRedundancy’

Entries in cfg file

SECT_ENTRY_LINE

STRING

‘LineType’

SECT_ENTRY_CMDREP

STRING

‘CmdRepeat’

SECT_ENTRY_RCV_TOUT_CL

STRING

‘ClientRcvTimeout’

SECT_ENTRY_TRS_TOUT_CL

STRING

‘ClientTrsTimeout’

SECT_ENTRY_RCV_TOUT_SV

STRING

‘ServerRcvTimeout’

SECT_ENTRY_TRS_TOUT_SV

STRING

‘ServerTrsTimeout’

SECT_ENTRY_HBT

STRING

‘HeartBeatTime’

SECT_ENTRY_WEB_TOUT

STRING

‘WebVisuCmdTimeout’

SECT_NAME_TCP

STRING

‘VisuRedundancyTCP’

SECT_TCP_USE_PEER

STRING

‘UseRedundParam’

SECT_TCP_IP_SO

STRING

‘IpAddressSwitchOver’

SECT_TCP_PORT_SO

STRING

‘PortSwitchOver’

SECT_TCP_CONNLBTOUT

STRING

‘ConnLineBreakTimeout’

SECT_TCP_CONNACTTOUT

STRING

‘ConnActiveTimeout’

SECT_TCP_TLS

STRING

‘UseTLS’

SECT_TCP_CERTTHUMB

STRING

‘Thumbprint’

SECT_TCP_CERTTHUMB_PEER

STRING

‘ThumbprintPeer’

SECT_TCP_CERTTHUMB_OLD

STRING

‘ThumbprintOLD’

SECT_TCP_CERTTHUMB_PEER_OLD

STRING

‘ThumbprintPeerOLD’

SECT_ENTRY_IP_LOCAL

STRING

‘Link1.IpAddressLocal’

SECT_ENTRY_IP_PEER

STRING

‘Link1.IpAddressPeer’

SECT_ENTRY_TCP_PORT

STRING

‘Link1.Port’

SECT_ENTRY_PLC_IDENT

STRING

‘PlcIdent’

SECT_ENTRY_TIMEOUT

STRING

‘StandbyWaitTime’

SECT_ENTRY_SECONDARY_IP_LOCAL

STRING

‘Link2.IpAddressLocal’

SECT_ENTRY_SECONDARY_IP_PEER

STRING

‘Link2.IpAddressPeer’

SECT_ENTRY_SECONDARY_TCP_PORT

STRING

‘Link2.Port’

SECT_ENTRY_HOSTNAME_LOCAL

STRING(253)

‘HostnameLocal’

Settings for multiple switchover adresses, new with visu 4.9.0.0

SECT_ENTRY_HOSTNAME_PEER

STRING(253)

‘HostnamePeer’

SECT_TCP_USE_SECONDARY_PEER

STRING

‘UseRedundSecondaryLink’

COMP_REDUND_NAME

STRING

‘CmpRedundancyConnectionIP’

COMP_REDUND_NAME2

STRING

‘CmpRedundancy’

TIME_CHECK_CERT

TIME

TIME#1m0s0ms

How often check if the certificate renew has to be done

TIME_CHECK_CERT_IN_TEST

TIME

TIME#2s0ms

when is running under test condition

STATE_NO

INT

0

States of certificate renewal

STATE_RENEW

INT

1

Renew

STATE_RENEW_DONE

INT

2

Renew

STATE_CFG

INT

3

Write config file

STATE_ACK

INT

4

Ack with server

STATE_BOOT

INT

5

boot new TLS session

STTLS_BOOT_NO

INT

0

States of TLS boot

STTLS_BOOT

INT

1

boot new TLS session

STTLS_BOOT_WAIT

INT

2

wait the boot condition

STTLS_BOOT_SET

INT

3

set the new certificate