VisuFbXYChartDataProvider (FB)¶
FUNCTION_BLOCK VisuFbXYChartDataProvider IMPLEMENTS IXYChartDataProvider3
This function block is the implementation of the IXYChartDataProvider interface. It is used by the generated code to provide suitable instances of this interface. An instance of this is present in generated code only
- InOut:
Scope
Name
Type
Comment
Input
iNumOfAxesINTAxes designed by the customer using configuration page Here I’ve: 1) the number of the axes 2) a pointer to array of pointers of structures containig the axis data.
Each cell can contain a structure allocated by the customer in IEC code and next assigned into configuration page or, if not, an automatic allocation of the same structure done by the system. In the first case customer can manipulate the data at run time, in the second case not
a pointer to array of BOOL to know if the variable used is local or user defined
a pointer to array of pointers of structures containig the axis properties written by generated code, from SP16.
paAxisVarPOINTER TO ARRAY [0..20] OF POINTER TO VisuStructXYChartAxis
paAxisIsLocVarPOINTER TO ARRAY [0..20] OF BOOL
paAxisVarProperPOINTER TO ARRAY [0..20] OF POINTER TO VisuStructXYChartAxis
iNumOfCurvesINTCurves designed by the customer using configuration page Here I’ve: 1) the number of the curves 2) a pointer to array of pointers of structures containig the curve data.
Each cell can contain a structure allocated by the customer in IEC code and next assigned into configuration page or, if not, an automatic allocation of the same structure done by the system. In the first case customer can manipulate the data at run time, in the second case not
a pointer to array of BOOL to know if the variable used is local or user defined
a pointer to array of pointers of structures containig the curves properties written by generated code, from SP16.
paCurveVarPOINTER TO ARRAY [0..20] OF POINTER TO VisuStructXYChartCurve
paCurveIsLocVarPOINTER TO ARRAY [0..20] OF BOOL
paCurveVarProperPOINTER TO ARRAY [0..20] OF POINTER TO VisuStructXYChartCurve
pElementVarPOINTER TO VisuStructXYChart
Pointer to the XY element structure, either the customer one or the system one, depending on if the customer has allocated the his one
xElementIsLocVarBOOLPoints to the XY element structure
pElementVarProperPOINTER TO VisuStructXYChart
If the variable used is local or user defined
eUpdateTypePoints to the XY system element structure where the generated code writes the properties defined at design time, from SP16 Update type
itfUpdateVarType of update used for element
itfAutoUpdEnaVarupdate variable
pItfDataProviderCurvePOINTER TO ARRAY [0..20] OF IXYChartDataProviderCurve
Automatic update enable variable Pointer to the interfaces of curves data provider
pItfDataProviderAxesPOINTER TO ARRAY [0..20] OF IXYChartDataProviderAxis
Pointer to the interfaces of axes data provider
itfCursXPosVarVariable of X axis value at cursor position, if present
paAxisStruWDPOINTER TO ARRAY [0..20] OF StruXYChartWorkingDataAxis
These data are instantiated in generated code, but not use there Because these data are “number of axes/curves depending”, I’ve defined them in generated code where I know those numbers In this way I don’t need dynamic allocation memory in IEC code
paCurveStruWDPOINTER TO ARRAY [0..20] OF StruXYChartWorkingDataCurve
Data for single curve elaboration, working data
Methods:
Structure:
- GetAxisFontLabel (Method)
- GetDataProviderCurve (Method)
- GetLineLevelFont (Method)
- GetLineLevelStruct (Method)
- GetNumberOfAxes (Method)
- GetNumberOfCurves (Method)
- GetPntAxis (Method)
- GetPntCurve (Method)
- GetPntData (Method)
- GetPntWorkingDataAxis (Method)
- GetPntWorkingDataCurve (Method)
- GetUpdateType (Method)
- GetVariableItf (Method)
- IXYChartDataProvider2
- IXYChartDataProvider3
- IsAxisVarLocal (Method)
- IsCurveVarLocal (Method)
- IsElementVarLocal (Method)