Visu_Globals (GVL)¶
- InOut:
- Name - Type - Initial - Comment - g_pVisuTextBuffer - POINTER TO ARRAY [0..Visu_Constants.VISU_TEXTBUFFER_SIZE] OF WORD - Is used when size is configured - g_iConfiguredTextBufferSize - INT- -1 - g_VisuManager - g_VisuManager_Inst - could be used by endusers too -> visible - g_SelectionManager - g_SelectionManager_Inst - Current selection manager instance. For more information see ISelectionManager - g_VisualizationStyle - Private_Visu_Globals.g_VisualizationStyle_Dummy_Inst - initialized with a private dummy instance to prevent having NULL values; qualified due to a current limitaion of the ieccodeconverter - g_VisuRectangleProvider - 0 - If an instance is assigned to this variable, then this instance will be called whenever a new list of touch rectangles is built. - CURRENTVISU - STRING- ‘’ - will be used only if the settings activate them - @IECCodeConverter_Type: String - CURRENTLANGUAGE - STRING- ‘’ - is always active - CurrentUserGroupId - DWORD- Visu user mgmt variables - only necessary for target clients - CHECKED_OMIT - CurrentUserGroupName - WSTRING(511)- CHECKED_OMIT - CurrentUserName - WSTRING- “None” - CHECKED_OMIT - CurrentFullUserName - WSTRING- “None” - CHECKED_OMIT - CurrentUseAutoLogoutTime - BOOL- CHECKED_OMIT - CurrentRemainingAutoLogoutTime - TIME- Only valid if CurrentUseAutoLogoutTime is TRUE. - CurrentClientType - CHECKED_OMIT - VISU_CYCLE_TIME_ON_OPEN_DIALOGS - UDINT- 1000 - Settings for performance optimizatin on open dialogs - OPEN_DIALOGS_DISABLE_CHANGING_INVALIDATION_RECT - BOOL- FALSE - g_VisuKineticScrollingSizeFactor - REAL- 1.0 - g_VisuKineticScrollingDamping - REAL- 0.1 - g_VisuTouchScrollingOutsideElem - BOOL- FALSE - g_VisuLineJoinMiterLimit - REAL- 1.5 - g_MaxTwoDigitYear - UINT- 2099 - g_DateTimeValuesInIECSyntax - BOOL- FALSE - g_VisuRedundSyncFrameIndex - BOOL- FALSE - Set the behavior of how to syncronize the frames indexes in during visu redundancy - g_VisuRedundValueChanged - VisuEnumRedundancyValueChanged.OnlySyncArea - Set the action to do when in visu redundancy we change a visu variable on the active device. - SECURE_TAPPING_TIMEOUT - DWORD- 2000 - Timeout in ms for secure tapping. If there is no connection for this period of time, all current Tap actions are automatically terminated. - g_xForceDlgPosAsDesigned - BOOL- How to handle the position of dialog box when no valid previous position has been found - g_xUseGlobalDlgPos - BOOL- TRUE - Allow to use the global dialog position when a new client is opened - g_VisuTrendWithTimeSelectorUpdateBehaviour - UINT- 100 - For a trend with time selector: The update rate can be dependent on the value of the time selector Value 0: Update rate not dependent on time selector value. Feature is not used. Values > 0: Update rate dependent on time selector value. Update rate of trend will be: time selector value / g_VisuTrendWithTimeSelectorUpdateBehaviour (Hint: A update, faster than the visu task is not possible. Also a update rate less than ms is not possible) 