CODESYS GmbH
  • Deutsch
  • English
  • Français
  • Español
  • Italiano
  • Русский
  • 日本語
  • 中文
Menu
Search
  • Deutsch
  • English
  • Français
  • Español
  • Italiano
  • Русский
  • 日本語
  • 中文
  • Library Information
    • GetLibVersion (Function)
    • GetLibVersionNumber (Function)
    • IsLibReleased (Function)
  • Private Implementation
    • Benchmarking
      • VisuBenchmarkFBStatistics (FunctionBlock)
      • VisuBenchmarkNowInUs (Function)
    • Debugging
      • DebugItfAddrToItfPtr (Function)
    • Enumerations
      • VisuClientTag (Enum)
      • VisuEnumBackgroundDrawingState (Enum)
      • VisuEventTarget (Enum)
    • InputInfo
      • Visu_FctGetElementFromInputInfo (Function)
      • Visu_FctGetElementIndexFromID (Function)
      • Visu_FctGetSubElementFromIndex (Function)
    • Interfaces
      • IClientObjectInfo (Interface)
        • GetClientObject (Method)
        • GetTransformationData (Method)
        • SetTransformationData (Method)
      • ICompactTextListInfo2 (Interface)
        • GetUsedLINTTextids (Method)
      • ICompleteSurroundingRectInfo (Interface)
        • GetCompleteSurroundingRectInfo (Method)
      • IContainerPaintSelf (Interface)
        • PaintSelf (Method)
      • IDrawSequentially (Interface)
      • IFrameElement2 (Interface)
        • GetVisuStartEndIndex (Method)
      • IFrameElement3 (Interface)
        • SetVisuIndex3 (Method)
      • ISelectableInside (Interface)
        • GetOuterRectangle (Method)
      • ITextListWrapper (Interface)
        • Count (Property)
        • GetElementAt (Method)
      • ITransformationImplProvider (Interface)
        • GetTransformation (Method)
      • IVisuUserMgmtCyclicCall (Interface)
        • CyclicCall (Method)
      • Multitouch
        • IInputRectangle (Interface)
        • IInputRectangleMgr (Interface)
        • IInputRectangleProvider (Folder)
        • IMultitouchElement (Folder)
        • IOptionalMultitouchElement (Interface)
        • IScrollValueProvider (Interface)
    • Resources
      • Allocation
        • IDatasourcesResourceEntryAllocator (Interface)
        • VisuFbDatasourcesResourceEntries_MBM (FunctionBlock)
        • VisuFbDatasourcesResourceEntries_SysMem (FunctionBlock)
        • VisuFctDatasourcesResourceEntryAllocatorGet (Function)
        • VisuFctDatasourcesResourceEntryAllocatorGet_MBM (Function)
        • VisuFctDatasourcesResourceEntryAllocatorGet_SysMem (Function)
      • VisuFbResourcesEntryVector (FunctionBlock)
        • AddEntry (Method)
        • Get (Method)
        • Overrides-and-Implementations
      • Visu_FctGetDatasources (Function)
    • Structures
      • InputDataSave (Struct)
      • VisuStructBackgroundAndStaticElementDrawing (Struct)
      • VisuStructCompleteSurroundingRectInfo (Struct)
      • VisuStructFindElementEvent (Struct)
      • VisuStructInputInfo (Struct)
      • VisuStructPAADialogClientSpecificData (Struct)
      • VisuStructSecureTappingKeyEvent (Struct)
      • VisuStructTextAndId (Struct)
      • VisuStructTopMostDialogInfo (Struct)
      • VisuStructUpdateRectangle (Struct)
    • TL_ElementProperties (TextList)
    • Tests
      • HeapInspectionInfo (Struct)
      • Inspect_Heap (FunctionBlock)
    • Utilities
      • Capturing
        • VisuFbCapturedTransformationProvider (FunctionBlock)
        • VisuFbLegacyCapturingTransformationProvider (FunctionBlock)
      • Clienthandling
        • Client Tags
        • Main Clienthandling
        • VisuFbClientStartVisuMgr (FunctionBlock)
        • Visu_FctReleaseNonIECMemClientResources (Function)
      • Collections
        • VisuFbCommandVector (FunctionBlock)
        • Visu_FbStringDintMap (FunctionBlock)
        • Visu_StructCommandData (Struct)
      • Colors
        • VisuFctIsTransparentBackground (Function)
        • VisuFctSplitColor (Function)
      • Date and Time
        • Access to Systime library
        • Recent
        • VisuFbDateTimeNamesLocalizer (FunctionBlock)
      • Dialog Management
        • Position infos
        • Structures
        • VisuDialogOpenFlags (Enum)
        • VisuFbDialogClientInfo (FunctionBlock)
        • VisuFbDialogInfoVector (FunctionBlock)
        • Visu_FctSetDialogClientData (Function)
      • ElementSearch
        • VisuFctSearchElementById (Function)
      • Event Handling
        • EventQueueAndElement (Struct)
        • EventQueuePerClient
        • LegacyRTSVisuStructEvent2 (Struct)
        • VisuFctHandleInputOnElementEvent (Function)
        • Visu_FbClearEventsAfterStart (FunctionBlock)
        • Visu_FctLegacyIDStackInfoFill (Function)
        • Visu_FctLegacyIDStackInfoReadFromAdditionalData (Function)
      • File transfer
        • VisuEnumFileTransferDirection (Enum)
        • VisuEnumFileTransferInputEventType (Enum)
        • VisuFbFileTransferManager (FunctionBlock)
        • VisuStructFileTransfParams_Union (Union)
      • Frame Switching
        • VisuFbFrameRegistrationVector (FunctionBlock)
      • GVL_DebugChecks (GVL)
      • Geometrics
        • VisuFbPaintRectF (FunctionBlock)
        • VisuFbPointF (FunctionBlock)
        • VisuFbRectF (FunctionBlock)
        • VisuFbSizeF (FunctionBlock)
      • Gestures
        • VisuFbGestureFromEvent (FunctionBlock)
        • VisuGestureInfo (Union)
        • VisuStructFlickInfo (Struct)
        • VisuStructIECTouchInfo (Struct)
        • VisuStructPanInfo (Struct)
        • VisuStructSpreadPinchInfo (Struct)
        • Visu_FctIsGestureEvent (Function)
        • Visu_FctIsRelevantGestureEvent (Function)
      • Input Event Handling
        • Visu_FctRaiseMouseLeave (Function)
      • Inputs
        • HandleVisuInput
        • VisuFbMouseTouchDragUtil (FunctionBlock)
        • VisuFctClearEventIdStack (Function)
        • VisuFctCreateIdStack (Function)
        • VisuFctEventIdStackGetValue (Function)
        • VisuFctEventIdStackGetValuePtr (Function)
        • VisuFctEventIdStackGetValuePtrFromEvent2 (Function)
        • VisuFctEventIdStackGetValuePtrFromEventLegacy (Function)
        • VisuFctEventIdStackHas (Function)
        • VisuFctEventIdStackPopHelp (Function)
        • VisuFctEventIdStackPopId (Function)
        • VisuFctEventIdStackPopTarget (Function)
        • VisuFctEventIdStackPopVisuVersion (Function)
        • VisuFctEventIdStackPushId (Function)
        • VisuFctEventIdStackSetValue (Function)
        • VisuFctSetSelectionChanged (Function)
        • Visu_FctHandleInputGesture (Function)
        • Visu_FctIsEventToIgnoreWhileEditboxOpen (Function)
        • Visu_FctIsModalDialogOpen (Function)
      • Namespaces Table
        • VisuFbLibHierarchy (FunctionBlock)
        • VisuFbNamespaceTable (FunctionBlock)
        • VisuStructNamespace (Struct)
        • VisuStructNamespaceProjectIdent (Struct)
        • Visu_HelpDumpLibHierarchy (Function)
      • Native Control
        • VisuFbNativeControlItemVector (FunctionBlock)
      • NativeElement
        • ArrayRangeHelper (FunctionBlock)
      • OnlineChange
        • Visu_OnlinechangeNotify (Function)
        • Visu_SetCodegenFeatureSupport (Function)
      • PaintAfterAllDialog
        • VisuFbPaintAfterAllDialog (FunctionBlock)
        • VisuFctExitVisuClientObject (Function)
        • VisuFctHandleInputVisuClientObject (Function)
        • VisuFctInitFlagsVisuClientObject (Function)
        • VisuFctInitVisuClientObject (Function)
        • VisuFctPaintVisuClientObject (Function)
        • VisuFctSetClientDataVisuClientObject (Function)
      • PropertySupport
        • Visu_CheckPropertyInfo (Function)
        • Visu_ScalarTypesUnion (Union)
        • Visu_ScalarTypesWithPtr (Struct)
      • Selection Management
        • IPaintSelectionInElement (Interface)
        • VisuFctIsToPaintSelection (Function)
        • Visu_FctIsOnStraightLine (Function)
        • Visu_FctIsSelectionEmpty (Function)
        • Visu_FctTransformSelectionIsotropicOverlay (Function)
      • StringFunctions
        • Visu_FctCheckForLongFormatSpecifier (Function)
      • Styles
        • VisuStyleFct_GetImageAccordingMapping (Function)
      • Transformation
        • VisuFbTransformationCommon (FunctionBlock)
        • VisuFbTransformationScrolling (FunctionBlock)
      • TypeInformation
        • SetValueOfTypeDesc (Function)
      • User Events
        • VisuStructInputOnElementEvent (Struct)
      • Visu Element Management
        • ClientObjectInfo
        • IVisualElementWithoutBlobInit (Interface)
        • VisuClientAnimationData (Struct)
        • VisuClientObject (FunctionBlock)
        • VisuClientObjectClientSpecificData (Struct)
        • VisuClientObjectFlags (Enum)
        • VisuClientObjectIdStack (FunctionBlock)
        • VisuClientObjectIdStackOptimized (FunctionBlock)
        • VisuClientObjectIdStackWithParentSize (FunctionBlock)
        • VisuClientObjectInputRectangleMgr (FunctionBlock)
        • VisuClientObjectLayerInitFlags (Enum)
        • VisuClientObjectMgr (FunctionBlock)
        • VisuClientObjectReservedIds (Enum)
        • VisuClientObjectStateFlags (Enum)
        • VisuElemLayer
        • VisuElemMgrClientData (Struct)
        • VisuElemMgrClientSpecificData (Struct)
        • VisuElemMgrClientSpecificDataIndices (Struct)
        • VisuScrollValueData (FunctionBlock)
        • VisuScrollValueProvider (FunctionBlock)
      • Visu Execution
        • VisuFbExecution (FunctionBlock)
        • VisuFctDrawIsoBackground (Function)
      • Visu Management
        • VisuFbVisuVector (FunctionBlock)
      • Visu Scaling
        • Touch Handling
        • VisuFbScalingInfo (FunctionBlock)
        • VisuStructScaleScrollInfo (Struct)
      • VisuEventOptimization (FunctionBlock)
        • AssignEvent (Method)
        • CanBeHandledWihtoutPainting (Method)
        • IsSameMouseMoveEvent (Method)
      • VisuFbBaseVector (FunctionBlock)
        • InitStaticMemory (Method)
        • RemoveEntryAt (Method)
      • VisuFbClientLogger (FunctionBlock)
        • WriteMessageInBuffer (Method)
      • VisuFbDWORDVector (FunctionBlock)
        • AddDWORD (Method)
        • GetDWORD (Method)
        • Overrides-and-Implementations
      • VisuFbInputRectangle (FunctionBlock)
        • Bottom (Property)
        • Checksum (Method)
        • Flags (Property)
        • Height (Property)
        • Left (Property)
        • Right (Property)
        • Top (Property)
        • Width (Property)
      • VisuFbNamespaceTableHelper (FunctionBlock)
        • GetNextAccessPath (Method)
        • SetInitAccessPath (Method)
        • prvDeriveNamespaceFromAccessPath (Method)
        • prvFindInitialNamespaceIndex (Method)
      • VisuFbPaintAfterAllElement (FunctionBlock)
        • ContainsPoint (Method)
        • Destruct (Method)
        • ElementInfo (Method)
        • GetAdditionalClientDataSize (Method)
        • GetClientData (Method)
        • GetSurroundingRect (Method)
        • GetText (Method)
        • GetTextProperties (Method)
        • GetTooltip (Method)
        • GetUpdateRects (Method)
        • HandleInput (Method)
        • ICapturingElement
        • IInputRectangleProvider
        • ILayeredVisualElement
        • IMultitouchElement
        • IRectangleProvider
        • IVisualElement3
        • Initialize (Method)
        • Paint (Method)
        • SetCallbackTarget (Method)
        • SetClientData (Method)
        • SetStaticState (Method)
        • Update (Method)
      • VisuFbTemporaryPolygon (FunctionBlock)
        • Copy (Method)
        • CopyToF (Method)
      • VisuFbValueChangedListenerForOnValueChanged (FunctionBlock)
        • ValueChanged (Method)
      • VisuFctAssignValue (Function)
      • VisuFctClearElementEntries (Function)
      • VisuFctGetEffectiveTextProperties (Function)
      • VisuFctGetElementState (Function)
      • VisuFctGetLineJoinMiterLimit (Function)
      • VisuFctIsMultitouchClient (Function)
      • VisuFctRectSize (Function)
      • VisuFctSetNumericValue (Function)
      • VisuFctSetRectangleUpdateNecessaryOnAllClients (Function)
      • VisuFctTextAddOffset (Function)
      • VisuFctTryAtomicAssignValueBySize (Function)
      • VisuFctTryAtomicAssignValueByType (Function)
      • VisuFctWriteValueIfValid (Function)
      • VisuFct_IsBehindOverlayElement (Function)
      • VisuRegistrationHelpDuringDecl (Function)
      • VisuSecureTappingKeyEvent (FunctionBlock)
        • AssignEvent (Method)
        • DoSecureTapping (Method)
      • Visu_Assert (Function)
      • Visu_FctGetDevicePixelRatioFromAdditionalData (Function)
      • Visu_FctInitMemSet (Function)
      • Webvisu
        • Visu_FbWebserver (FunctionBlock)
    • Visu_PRG (Program)
      • CheckSecureTapping (Action)
      • CheckUnusedClients (Action)
      • ClientRelevantOnlineChangeDone (Action)
      • DoCurrentVisuHandling (Action)
      • HandleForIntegratedVisu (Method)
      • Initialization (Action)
      • InitializeVisusAndDialogs (Method)
      • InvalidateAllClients (Action)
      • IsRunning (Property)
      • KeepAliveClients (Property)
      • RemoveAllTargetVisuClients (Action)
      • ResourcesOnlineChangeHandling (Action)
  • Public Parts
    • Animations
      • Tap Awareness
        • VisuFbAnalyzeStateVarsTapAware (FunctionBlock)
        • VisuFbMoveAbsoluteTapAware (FunctionBlock)
        • VisuFbMoveAbsoluteTapAwareF (FunctionBlock)
        • VisuFbMoveRelativeTapAware (FunctionBlock)
      • VisuFbAnalyzeTextVarsDateTimeOnly (FunctionBlock)
        • GetAsDWORD (Method)
        • GetAsLINT (Method)
        • GetAsLWORD (Method)
        • GetType (Method)
        • Initialize (Method)
    • Enumerations
      • VisuEnumActionType (Enum)
      • VisuEnumAfterTransformation (Enum)
      • VisuEnumAttachedElementLocation (Enum)
      • VisuEnumBrushStyle (Enum)
      • VisuEnumCreateTemporaryRenderLocationFlags (Enum)
      • VisuEnumFileTransferError (Enum)
      • VisuEnumHorizontalAlignment (Enum)
      • VisuEnumInputOnElementType (Enum)
      • VisuEnumIsotropicType (Enum)
      • VisuEnumLineCapStyle (Enum)
      • VisuEnumLineJoinStyle (Enum)
      • VisuEnumOrientation (Enum)
      • VisuEnumPenStyle (Enum)
      • VisuEnumPieType (Enum)
      • VisuEnumPolygonType (Enum)
      • VisuEnumPropertyElement (Enum)
      • VisuEnumRectangleFlags (Enum)
      • VisuEnumRedundancyValueChanged (Enum)
      • VisuEnumTextFlag (Enum)
      • VisuEnumVerticalAlignment (Enum)
      • VisuTouchState (Enum)
      • Visu_ClientType (Enum)
      • Visu_DialogResult (Enum)
    • Functions
      • VisuFctAddChecksumBool (Function)
      • VisuFctAddChecksumForConverted (Function)
      • VisuFctAdjustElemRectAndSelectRect (Function)
      • VisuFctCalculateCompleteSurroundingSimpleRectOfElemArray (Function)
      • VisuFctCalculateSurroundingSimpleRectOfElemArray (Function)
      • VisuFctCheckClientSupportsTouch (Function)
      • VisuFctConfigureTextBufferSize (Function)
      • VisuFctEvaluatePanGesture (Function)
      • VisuFctGetElementClientData (Function)
      • VisuFctGetElementEntry (Function)
      • VisuFctGetMeasureString2Result (Function)
      • VisuFctGetMeasureStringResult (Function)
      • VisuFctGetMultitouchActive (Function)
      • VisuFctGetMultitouchScrollbarsActive (Function)
      • VisuFctGetPaintRectFromSimpleRect (Function)
      • VisuFctGetRectangleFromPaintRect (Function)
      • VisuFctGetRectangleFromSimpleRect (Function)
      • VisuFctGetTextMargins (Function)
      • VisuFctHandleInputWithoutInputHandler (Function)
      • VisuFctIncreaseSimpleRectIfRotated (Function)
      • VisuFctIsDegenerateRectangle (Function)
      • VisuFctIsRectangleRotated (Function)
      • VisuFctLimitSimpleRectangleSize (Function)
      • VisuFctPaintSelection (Function)
      • VisuFctSelectElement (Function)
      • VisuFctSetMaxElementCountPaintAfterAll (Function)
      • VisuFctSetSimpleRect (Function)
      • VisuFctSimpleRectangleFToSimpleRectangle (Function)
      • VisuFctUtf8RuneLen (Function)
    • GVLs
      • Visu_DateTime (GVL)
      • Visu_Globals (GVL)
    • Interfaces
      • IApplicationRectangleProvider (Interface)
        • ProvideRectangles (Method)
      • ICallOnDialogBlocks (Interface)
        • Execute (Method)
      • ICallOnVisuBlocks (Interface)
        • Execute (Method)
      • IClippingLayer (Interface)
        • ClippingActive (Property)
        • ClippingRect (Property)
      • ICustomEventHandler (Interface)
        • HandleCustomEvent (Method)
      • IDialogCloseListener (Interface)
        • DialogClosed (Method)
      • IDialogCloseListenerWithTag (Interface)
        • DialogClosedWithTag (Method)
      • IDialogManager2 (Interface)
        • CheckEventQueue (Method)
        • CloseDialog2 (Method)
      • IDialogManager3 (Interface)
        • CollectRectangles (Method)
        • HasOpenModalDialog (Method)
      • IDialogManager4 (Interface)
        • CallOnAllDialogs (Method)
        • GetRegisteredDialogsBlockwise (Method)
      • IDialogManager5 (Interface)
        • GetDialogToClose (Method)
        • GetDialogToOpen (Method)
        • IsDialogOpen (Method)
      • IDialogManager6 (Interface)
        • SetTopMostDialogRect (Method)
      • IDialogManager7 (Interface)
        • CalculateDialogPositionForPAA (Method)
        • ClosePAADialog (Method)
        • SetPAADialogOpenObject (Method)
        • getPaintAfterAllOpen (Method)
        • getVersion (Method)
      • IDialogManager8 (Interface)
        • HandleInputBefore (Method)
      • IDialogManager9 (Interface)
        • SetClientDataWithoutStartCycle (Method)
      • IDrawingInterface3 (Interface)
        • UntransformHeight (Method)
        • UntransformWidth (Method)
      • IFrameManager (Interface)
        • GetFrameCount (Method)
        • GetRegisteredFrames (Method)
        • GetSelectedVisu (Method)
        • GetVisuCount (Method)
        • GetVisuName (Method)
        • RegisterFrame (Method)
        • SwitchToVisuGlobally (Method)
        • UnregisterFrame (Method)
      • IFrameManager2 (Interface)
        • GetFrameByIndex (Method)
        • GetSelectedVisuByIndex (Method)
        • SwitchToVisu2 (Method)
        • SwitchToVisuByIndex (Method)
      • IFrameManagerBase (Interface)
        • SwitchToVisu (Method)
      • IGestureEventHandler (Interface)
        • HandleFlickGesture (Method)
        • HandlePanGesture (Method)
        • HandleSpreadPinchGesture (Method)
      • IGestureEventHandler2 (Interface)
        • HandleTouchEvent (Method)
      • IGestureEventHandler3 (Interface)
        • HandleTouchEvent2 (Method)
      • IGridProvider (Interface)
        • GetColumnWidth (Method)
        • GetRowHeight (Method)
        • NumberOfColumns (Property)
        • NumberOfRows (Property)
      • IInputOnElementEventHandler (Interface)
        • HandleInputOnElementEvent (Method)
      • IKeyEventHandler (Interface)
        • HandleKeyEvent (Method)
      • ILayerManager (Interface)
        • EndLayer (Method)
        • SetAdditionalLayers (Method)
        • StartLayer (Method)
      • ILayeredVisualElement (Interface)
        • SetLayerManager (Method)
      • IMouseEventHandler (Interface)
        • HandleMouseBtnEvent (Method)
        • HandleMouseMoveEvent (Method)
      • IPAADialog (Interface)
        • ClosePAADialog (Method)
        • CollectRectangles (Method)
        • HandlePAASelection (Method)
        • SetTransformPAA (Method)
      • IPaintAfterAll (Interface)
        • PAAClose (Method)
        • PAAgetSize (Method)
        • PAAgetSurroundingRect (Method)
        • PAAgetUpdateRects (Method)
        • PAAhandleInputBefore (Method)
        • PAApaintAfterAll (Method)
      • IPaintAfterAll2 (Interface)
        • PAAGetTouchContentSurroundingRect (Method)
        • PAAInitialize (Method)
      • IPaintAfterAllOwningElement (Interface)
        • OwningElement (Property)
      • IPaintAfterAllRectangleProvider (Interface)
        • PAAAddRectangles (Method)
      • IPaintAfterAllSelection (Interface)
        • HandlePAASelection (Method)
      • IProvidesTabOrder (Interface)
        • GetTabOrderIdArray (Method)
      • IRectangleListManager (Interface)
        • AddRectangle (Method)
        • AddZoomScrollLimits (Method)
        • ForwardCall (Method)
        • ForwardCallWithMouseDownInfo (Method)
        • PopClipping (Method)
        • PushClipping (Method)
        • SetUpdateNecessary (Method)
      • IRectangleListManager2 (Interface)
        • AddContentRect (Method)
        • AddRectangleTransformed (Method)
        • AddTouchRectRenderLocationInfo (Method)
        • PushClippingTransformed (Method)
      • IRectangleListManager3 (Interface)
        • AddContentRectTransformed (Method)
      • IRectangleListManager4 (Interface)
        • AddLargeScrollLimits (Method)
      • IRectangleProvider (Interface)
        • AddRectangles (Method)
      • IRequiresInitMeasureString (Interface)
      • ISelectionManager (Interface)
        • DoSelectedAction (Method)
        • EnabledSelectionType (Property)
        • FrameOffset (Property)
        • ResetSelection (Method)
        • SelectElement (Method)
        • SelectElementAt (Method)
        • SelectNextElement (Method)
        • SelectionColors (Property)
        • SelectionLook (Property)
      • ISpecialEventHandler (Interface)
        • HandleSpecialEvent (Method)
      • ISupportsRealDrawing (Interface)
        • Center (Property)
        • MoveAbsolute (Property)
        • RealDrawing (Property)
      • IUserMgmtEventHandler (Interface)
        • HandleLogin (Method)
        • HandleLoginFailed (Method)
        • HandleLogout (Method)
        • HandlePasswordChange (Method)
      • IValueChangedListener (Interface)
        • ValueChanged (Method)
      • IVisuManager (Interface)
        • GetCurrentVisu (Method)
        • GetDialogManager (Method)
        • GetFrameManager (Method)
        • GetRegisteredVisus (Method)
        • GetVisuCount (Method)
        • SetMainVisuGlobally (Method)
        • SetStartVisu (Method)
      • IVisuManager2 (Interface)
        • CallOnAllVisus (Method)
        • GetRegisteredVisusBlockwise (Method)
      • IVisuManager3 (Interface)
        • GetNextShownVisu (Method)
        • GetPreviousShownVisu (Method)
      • IVisuManagerBase (Interface)
        • GetDialogManagerBase (Method)
        • GetFrameManagerBase (Method)
        • GetInternCommandManagerBase (Method)
        • LastMainVisu (Method)
        • NextMainVisu (Method)
        • RegisterVisu (Method)
        • SetMainVisu (Method)
        • UnregisterVisu (Method)
      • IVisuStreamFileNameInfo (Interface)
        • FileNameProposal (Property)
      • IVisuStreamHandler (Interface)
        • EndOperation (Method)
        • StartOperation (Method)
      • IVisuStreamReader (Interface)
        • Read (Method)
      • IVisuStreamSetFileName (Interface)
        • FileName (Property)
      • IVisuStreamWriter (Interface)
        • Write (Method)
      • IVisuUserEventManager (Interface)
        • SetCustomEventHandler (Method)
        • SetEditBoxEventHandler (Method)
        • SetGestureEventHandler (Method)
        • SetInputOnElementEventHandler (Method)
        • SetKeyEventHandler (Method)
        • SetMouseEventHandler (Method)
        • SetSpecialEventHandler (Method)
        • SetUserMgmtEventHandler (Method)
      • IVisualElementLayer (Interface)
        • Initialized (Property)
        • Paint (Method)
      • IVisualElementOfflineScaling (Interface)
        • SetOfflineScalingFactors (Method)
      • IVisualElementProvidesChildElements (Interface)
        • GetElementIdArray (Method)
      • IVisualElementProvidesSubElements (Interface)
        • GetSubElements (Method)
      • IVisualisationAccessRights (Interface)
        • HasInputAccess (Method)
        • HasVisibilityAccess (Method)
      • IVisualizationStyle (Interface)
        • GetColor (Method)
        • GetDINT (Method)
        • GetFont (Method)
        • GetFontWithColor (Method)
        • GetString (Method)
        • GetUDINT (Method)
    • Structures
      • VisuStructClientTagData (Struct)
      • VisuStructColors (Struct)
      • VisuStructElementState (Struct)
      • VisuStructFont (Struct)
      • VisuStructPointD (Struct)
      • VisuStructRadius (Struct)
      • VisuStructSimpleRectWithBorder (Struct)
      • VisuStructSimpleRectangleD (Struct)
      • VisuStructSingleIECTouchInfo (Struct)
      • VisuStructTextProperties (Struct)
    • Types
      • Visu_TypeString (Alias)
  • File and Project Information
  • Library Reference
    • 3SLicense
      • Library Identification
      • Library Properties
    • Base Interfaces
      • Library Identification
      • Library Properties
    • CAA FB Factory
      • Library Identification
      • Library Properties
    • CAA Memory Block Manager Extern
      • Library Identification
      • Library Properties
    • CAA Types Extern
      • Library Identification
      • Library Properties
    • CmpApp
      • Library Identification
      • Library Properties
    • CmpBitmapPool
      • Library Identification
      • Library Properties
    • CmpCodeMeter
      • Library Identification
      • Library Properties
    • CmpCrypto Implementation
      • Library Identification
      • Library Properties
    • CmpCrypto Interfaces
      • Library Identification
      • Library Properties
    • CmpDynamicText
      • Library Identification
      • Library Properties
    • CmpErrors2 Interfaces
      • Library Identification
      • Library Properties
    • CmpEventMgr Implementation
      • Library Identification
      • Library Properties
    • CmpEventMgr Interfaces
      • Library Identification
      • Library Properties
    • CmpLog
      • Library Identification
      • Library Properties
    • CmpSchedule
      • Library Identification
      • Library Properties
    • CmpTargetVisu
      • Library Identification
      • Library Properties
    • CmpUserMgr
      • Library Identification
      • Library Properties
    • CmpVisuHandler
      • Library Identification
      • Library Properties
    • Collections
      • Library Identification
      • Library Properties
    • Component Manager
      • Library Identification
      • Library Properties
    • Data Server Interfaces
      • Library Identification
      • Library Properties
    • Datasources Interfaces
      • Library Identification
      • Library Properties
    • Element Collections
      • Library Identification
      • Library Properties
    • FloatingPointUtils
      • Library Identification
      • Library Properties
    • IecVarAccess3 Interfaces
      • Library Identification
      • Library Properties
    • Standard
      • Library Identification
      • Library Properties
    • Standard64
      • Library Identification
      • Library Properties
    • StringUtils
      • Library Identification
      • Library Properties
    • SysCpuHandling
      • Library Identification
      • Library Properties
    • SysFile
      • Library Identification
      • Library Properties
    • SysMem
      • Library Identification
      • Library Properties
    • SysProcess
      • Library Identification
      • Library Properties
    • SysShm
      • Library Identification
      • Library Properties
    • SysTarget
      • Library Identification
      • Library Properties
    • SysTime
      • Library Identification
      • Library Properties
    • SysTimeRtc
      • Library Identification
      • Library Properties
    • SysTypes2 Interfaces
      • Library Identification
      • Library Properties
    • Unit Conversion Interfaces
      • Library Identification
      • Library Properties
    • Util
      • Library Identification
      • Library Properties
      • Library Parameter
    • Visu Interfaces
      • Library Identification
      • Library Properties
    • VisuUserMgmt3 Interfaces
      • Library Identification
      • Library Properties
VisuElemBase
  • Docs »
  • Private Implementation »
  • Utilities »
  • Transformation »
  • VisuFbTransformationScrolling (FB)

VisuFbTransformationScrolling (FB)ΒΆ

FUNCTION_BLOCK VisuFbTransformationScrolling EXTENDS VisuFbTransformationCommon

Methods:

TransformPoint

TransformPointInOut

TransformYCoordinate

UntransformPoint

Checksum, inherited from VisuFbTransformationCommon

SetOffset, inherited from VisuFbTransformationCommon

SetScaleValues, inherited from VisuFbTransformationCommon

SetTransformationValues, inherited from VisuFbTransformationCommon

SetTransformationValuesWithClientObjectPositions, inherited from VisuFbTransformationCommon

TransformFontSize, inherited from VisuFbTransformationCommon

TransformHeight, inherited from VisuFbTransformationCommon

TransformPaintRectangle, inherited from VisuFbTransformationCommon

TransformPaintRectangleInOut, inherited from VisuFbTransformationCommon

TransformPaintRectangleInOutF, inherited from VisuFbTransformationCommon

TransformPointInOutF, inherited from VisuFbTransformationCommon

TransformPointInOutOverlay, inherited from VisuFbTransformationCommon

TransformPointInOutOverlayF, inherited from VisuFbTransformationCommon

TransformPolygon, inherited from VisuFbTransformationCommon

TransformPolygonF, inherited from VisuFbTransformationCommon

TransformWidth, inherited from VisuFbTransformationCommon

UntransformHeight, inherited from VisuFbTransformationCommon

UntransformWidth, inherited from VisuFbTransformationCommon

Structure:

  • TransformPoint (Method)
  • TransformPointInOut (Method)
  • TransformYCoordinate (Method)
  • UntransformPoint (Method)
top

CODESYS Group | We software Automation. to software
['sɒftwɛər]
transitive verb
__softwared/softwaring
: to develop software
// to software automation: to develop software for automation purposes

The CODESYS Group is the manufacturer of CODESYS, the leading hardware-independent IEC 61131-3 automation software for developing and engineering controller applications.
CODESYS® is a registered trademark.

CODESYS GmbH
A member of the CODESYS Group
Memminger Straße 151, 87439 Kempten
Germany
Tel.: +49-831-54031-0
info@codesys.com
  • Legal Notice
  • Privacy Policy
LinkedIn Youtube RSS Downloads Login CODESYS Store
© 2022 CODESYS GmbH | A member of the CODESYS Group