IGestureEventHandler.HandleSpreadPinchGesture (METH)ΒΆ
METHOD HandleSpreadPinchGesture : BOOL
This method will be called when a spread/pinch gesture was detected by the visualiuation. RETURN: TRUE - When the handler has handled this event and it should not be handled by someone else FALSE - When the event is not handled by this handler
- InOut:
- Scope - Name - Type - Comment - Return - HandleSpreadPinchGesture- BOOL- Input - startCenter- VisuStructPoint- The center point of the gesture on the screen where it was started - center- VisuStructPoint- The center point of the gesture where it was finished - scaleFactor- REAL- The scale factor of this gesture - startOrientation- REAL- The orientation at the start of the gesture in degrees: 0 -> first touch right, second touch left 90 -> first touch bottom, second touch top 180 -> first touch left, second touch right 270 -> first touch top, second touch bottom - rotationAngle- REAL- The orientation at the end of the gesture in degrees: 0 -> first touch right, second touch left 90 -> first touch bottom, second touch top 180 -> first touch left, second touch right 270 -> first touch top, second touch bottom - pClient- POINTER TO VisuStructClientData - A pointer to the client structure were the event occurred. 