VisuDlg_ProcessChar (FUN)ΒΆ
FUNCTION VisuDlg_ProcessChar
This function takes a given character and appends/inserts it in the string representing the variable value. To decide, which action has to be performed, the current caret position and the currently selected text is evaluated.
- InOut:
Scope
Name
Type
Comment
Inout
stOutputValue
STRING
This is the string representation of the variable value, that will be displayed in the visualization. If the flag xPassword is TRUE the variable value will be display with password characters
stVariableValue
STRING
This parameter is the variable value, where the character is appended/inserted
iCaretPosition
INT
The current position of the caret. Either within the text or at the end of the text
iSelectionStart
INT
The start of the selected text (1-relative)
iSelectionEnd
INT
The end of the selected text (1-relative). If the complete text is selected this parameter is textlength + 1
Input
xPassword
BOOL
Inidicates, whether the entered value should be readable (FALSE) or displayed with password characters
cToConsume
STRING(4)
The character to append/insert