FbChangeVisu (FB)ΒΆ
FUNCTION_BLOCK FbChangeVisu EXTENDS FbExecuteSingleVisuActionBase
Changes the currently shown toplevel visualization
The fb-instance should be declarated within a permanent setting, e.g. a GVL, and not within a temporary setting, e.g. a function. Therefore, the action will still be available, when called, later on.
- InOut:
- Scope - Name - Type - Comment - Inherited from - Input - xExecute- BOOLRising edge: Starts defined operation- FALSE: Resets the defined operation after ready condition was reached- ETrig - Output - xDone- BOOL- TRUE: Ready condition reached- ETrig - xBusy- BOOL- TRUE: Operation is running- ETrig - xError- BOOL- TRUE: Error condition reached- ETrig - Input - itfClientFilter- With this filter, the clients, where the action should happen, are specified. - Use standard filter from GVL Globals, e.g. - VU.Globals.CurrentClient, or use a own implentation of the interface.- FbExecuteSingleVisuActionBase - Output - eError- FbExecuteSingleVisuActionBase - Input - sVisuName- STRING- The name of the visualization that should be shown. In case visualization names should be ambigous, the name can be qualified using the namespace. 