Services (GVL)ΒΆ
- Attributes:
qualified_only
- InOut:
Scope
Name
Type
Initial
Comment
Constant
SG_TraceManager
UINT
16#F
Service Groups
SG_TrendStorage
UINT
16#1E
SRV_TrendGetMinMaxTimestamps
UINT
16#83
Trend storage services
SRV_TrendReadTrendData
UINT
16#84
TAG_TrendApplicationName
UINT
16#1
Tags for the requests
TAG_TrendPacketName
UINT
16#2
TAG_TrendTimestamps
UINT
16#3
TAG_TrendVariables
UINT
16#4
TAG_TrendError
UINT
16#1
Tags for the responses
TAG_TrendGetMinMaxTimestamps
UINT
16#2
TAG_TrendCountVariables
UINT
16#3
TAG_TrendReadTrendDataVariables
UINT
16#85
TAG_TrendRelevantVariables
UINT
16#86
SUBT_TrendReadTrendDataVariable
UINT
16#5
TAG_TrendReadTrendDataTimestamps
UINT
16#6
TAG_TrendReadTrendDataData
UINT
16#7
SUBT_TrendRelevantVariable
UINT
16#8
TAG_TrendReadTrendDataValidity
UINT
16#9
TAG_TrendReadTrendDataPacket
UINT
16#A
SUBT_TrendVariableDescription
UINT
16#9
SUBT_TrendAttachedYAxis
UINT
16#A
SUBT_TrendLineProperties
UINT
16#B
SUBT_TrendAreaProperties
UINT
16#C
SRV_TrcPacketCreate
UINT
16#2
Trace manager services
SRV_TrcPacketDelete
UINT
16#3
SRV_TrcPacketComplete
UINT
16#4
SRV_TrcPacketOpen
UINT
16#5
SRV_TrcPacketClose
UINT
16#6
SRV_TrcPacketGetConfig
UINT
16#9
SRV_TrcRecordAdd
UINT
16#D
SRV_TrcPacketStart
UINT
16#A
SRV_TrcPacketStop
UINT
16#B
SRV_TrcPacketRead
UINT
16#7
SRV_TrcPacketResetTrigger
UINT
16#10
SRV_TrcPacketStore
UINT
16#11
SRV_TrcPacketRestore
UINT
16#12
SRV_TrcGetConfigFromFile
UINT
16#13
TAG_TrcPacketName
UINT
16#10
Tags for the requests
TAG_TrcPacketComment
UINT
16#16
TAG_TrcAppName
UINT
16#11
TAG_TrcTaskName
UINT
16#12
TAG_TrcEveryNCycles
UINT
16#13
TAG_TrcBufferEntries
UINT
16#14
TAG_TrcPacketFlags
UINT
16#15
TAG_TrcTrigger
UINT
16#86
TAG_TrcTriggerLevel
UINT
16#30
TAG_TrcTriggerEdge
UINT
16#31
TAG_TrcTriggerUpdatesAfterTrigger
UINT
16#34
TAG_TrcTriggerFlags
UINT
16#33
TAG_TrcVariable
UINT
16#83
TAG_TrcVariableAddressFlag
UINT
16#21
TAG_TrcVariableAddressArea
UINT
16#23
TAG_TrcVariableAddressOffset
UINT
16#24
TAG_TrcVariableName
UINT
16#20
TAG_TrcVariableTypeClass
UINT
16#25
TAG_TrcVariableSize
UINT
16#26
TAG_TrcPacketHandle
UINT
16#40
TAG_TrcError
UINT
16#FF7F
TAG_TrcGraphType
UINT
16#27
TAG_TrcGraphColor
UINT
16#28
TAG_TrcParameterId
UINT
16#29
TAG_TrcParameterModuleType
UINT
16#30
TAG_TrcParameterInstance
UINT
16#31
TAG_TrcActivateMinWarning
UINT
16#32
TAG_TrcCriticalLowerLimit
UINT
16#33
TAG_TrcMinWarningColor
UINT
16#34
TAG_TrcActivateMaxWarning
UINT
16#35
TAG_TrcCriticalUpperLimit
UINT
16#36
TAG_TrcMaxWarningColor
UINT
16#37
TAG_TrcSecondYAxis
UINT
16#38
TAG_TrcRecordHandle
UINT
16#41
TAG_TrcRecordConfiguration
UINT
16#84
TAG_TrcPacketTimestamp
UINT
16#4A
TAG_TrcTraceStateStruct
UINT
16#87
TAG_TrcTraceState
UINT
16#50
TAG_TrcTraceStartTime
UINT
16#51
TAG_TrcTriggerState
UINT
16#52
TAG_TrcTriggerTimestamp
UINT
16#53
TAG_TrcTraceChangeTime
UINT
16#55
TAG_TrcRecordBuffer
UINT
16#42
TAG_TrcRecordResult
UINT
16#47
TAG_TrcCondition
UINT
16#85
TAG_TrcFileName
UINT
16#4C