Services (GVL)ΒΆ

Attributes:
qualified_only
InOut:

Scope

Name

Type

Initial

Comment

Constant

SG_TraceManager

UINT

16#F

Service Groups

SG_TrendStorage

UINT

16#1E

SRV_TrendGetMinMaxTimestamps

UINT

16#83

Trend storage services

SRV_TrendReadTrendData

UINT

16#84

TAG_TrendApplicationName

UINT

16#1

Tags for the requests

TAG_TrendPacketName

UINT

16#2

TAG_TrendTimestamps

UINT

16#3

TAG_TrendVariables

UINT

16#4

TAG_TrendError

UINT

16#1

Tags for the responses

TAG_TrendGetMinMaxTimestamps

UINT

16#2

TAG_TrendCountVariables

UINT

16#3

TAG_TrendReadTrendDataVariables

UINT

16#85

TAG_TrendRelevantVariables

UINT

16#86

SUBT_TrendReadTrendDataVariable

UINT

16#5

TAG_TrendReadTrendDataTimestamps

UINT

16#6

TAG_TrendReadTrendDataData

UINT

16#7

SUBT_TrendRelevantVariable

UINT

16#8

TAG_TrendReadTrendDataValidity

UINT

16#9

TAG_TrendReadTrendDataPacket

UINT

16#A

SUBT_TrendVariableDescription

UINT

16#9

SUBT_TrendAttachedYAxis

UINT

16#A

SUBT_TrendLineProperties

UINT

16#B

SUBT_TrendAreaProperties

UINT

16#C

SRV_TrcPacketCreate

UINT

16#2

Trace manager services

SRV_TrcPacketDelete

UINT

16#3

SRV_TrcPacketComplete

UINT

16#4

SRV_TrcPacketOpen

UINT

16#5

SRV_TrcPacketClose

UINT

16#6

SRV_TrcPacketGetConfig

UINT

16#9

SRV_TrcRecordAdd

UINT

16#D

SRV_TrcPacketStart

UINT

16#A

SRV_TrcPacketStop

UINT

16#B

SRV_TrcPacketRead

UINT

16#7

SRV_TrcPacketResetTrigger

UINT

16#10

SRV_TrcPacketStore

UINT

16#11

SRV_TrcPacketRestore

UINT

16#12

SRV_TrcGetConfigFromFile

UINT

16#13

TAG_TrcPacketName

UINT

16#10

Tags for the requests

TAG_TrcPacketComment

UINT

16#16

TAG_TrcAppName

UINT

16#11

TAG_TrcTaskName

UINT

16#12

TAG_TrcEveryNCycles

UINT

16#13

TAG_TrcBufferEntries

UINT

16#14

TAG_TrcPacketFlags

UINT

16#15

TAG_TrcTrigger

UINT

16#86

TAG_TrcTriggerLevel

UINT

16#30

TAG_TrcTriggerEdge

UINT

16#31

TAG_TrcTriggerUpdatesAfterTrigger

UINT

16#34

TAG_TrcTriggerFlags

UINT

16#33

TAG_TrcVariable

UINT

16#83

TAG_TrcVariableAddressFlag

UINT

16#21

TAG_TrcVariableAddressArea

UINT

16#23

TAG_TrcVariableAddressOffset

UINT

16#24

TAG_TrcVariableName

UINT

16#20

TAG_TrcVariableTypeClass

UINT

16#25

TAG_TrcVariableSize

UINT

16#26

TAG_TrcPacketHandle

UINT

16#40

TAG_TrcError

UINT

16#FF7F

TAG_TrcGraphType

UINT

16#27

TAG_TrcGraphColor

UINT

16#28

TAG_TrcParameterId

UINT

16#29

TAG_TrcParameterModuleType

UINT

16#30

TAG_TrcParameterInstance

UINT

16#31

TAG_TrcActivateMinWarning

UINT

16#32

TAG_TrcCriticalLowerLimit

UINT

16#33

TAG_TrcMinWarningColor

UINT

16#34

TAG_TrcActivateMaxWarning

UINT

16#35

TAG_TrcCriticalUpperLimit

UINT

16#36

TAG_TrcMaxWarningColor

UINT

16#37

TAG_TrcSecondYAxis

UINT

16#38

TAG_TrcRecordHandle

UINT

16#41

TAG_TrcRecordConfiguration

UINT

16#84

TAG_TrcPacketTimestamp

UINT

16#4A

TAG_TrcTraceStateStruct

UINT

16#87

TAG_TrcTraceState

UINT

16#50

TAG_TrcTraceStartTime

UINT

16#51

TAG_TrcTriggerState

UINT

16#52

TAG_TrcTriggerTimestamp

UINT

16#53

TAG_TrcTraceChangeTime

UINT

16#55

TAG_TrcRecordBuffer

UINT

16#42

TAG_TrcRecordResult

UINT

16#47

TAG_TrcCondition

UINT

16#85

TAG_TrcFileName

UINT

16#4C