Services (GVL)ΒΆ
- Attributes:
- qualified_only
- InOut:
- Scope - Name - Type - Initial - Comment - Constant - SG_TraceManager - UINT- 16#F - Service Groups - SG_TrendStorage - UINT- 16#1E - SRV_TrendGetMinMaxTimestamps - UINT- 16#83 - Trend storage services - SRV_TrendReadTrendData - UINT- 16#84 - TAG_TrendApplicationName - UINT- 16#1 - Tags for the requests - TAG_TrendPacketName - UINT- 16#2 - TAG_TrendTimestamps - UINT- 16#3 - TAG_TrendVariables - UINT- 16#4 - TAG_TrendError - UINT- 16#1 - Tags for the responses - TAG_TrendGetMinMaxTimestamps - UINT- 16#2 - TAG_TrendCountVariables - UINT- 16#3 - TAG_TrendReadTrendDataVariables - UINT- 16#85 - TAG_TrendRelevantVariables - UINT- 16#86 - SUBT_TrendReadTrendDataVariable - UINT- 16#5 - TAG_TrendReadTrendDataTimestamps - UINT- 16#6 - TAG_TrendReadTrendDataData - UINT- 16#7 - SUBT_TrendRelevantVariable - UINT- 16#8 - TAG_TrendReadTrendDataValidity - UINT- 16#9 - TAG_TrendReadTrendDataPacket - UINT- 16#A - SUBT_TrendVariableDescription - UINT- 16#9 - SUBT_TrendAttachedYAxis - UINT- 16#A - SUBT_TrendLineProperties - UINT- 16#B - SUBT_TrendAreaProperties - UINT- 16#C - SRV_TrcPacketCreate - UINT- 16#2 - Trace manager services - SRV_TrcPacketDelete - UINT- 16#3 - SRV_TrcPacketComplete - UINT- 16#4 - SRV_TrcPacketOpen - UINT- 16#5 - SRV_TrcPacketClose - UINT- 16#6 - SRV_TrcPacketGetConfig - UINT- 16#9 - SRV_TrcRecordAdd - UINT- 16#D - SRV_TrcPacketStart - UINT- 16#A - SRV_TrcPacketStop - UINT- 16#B - SRV_TrcPacketRead - UINT- 16#7 - SRV_TrcPacketResetTrigger - UINT- 16#10 - SRV_TrcPacketStore - UINT- 16#11 - SRV_TrcPacketRestore - UINT- 16#12 - SRV_TrcGetConfigFromFile - UINT- 16#13 - TAG_TrcPacketName - UINT- 16#10 - Tags for the requests - TAG_TrcPacketComment - UINT- 16#16 - TAG_TrcAppName - UINT- 16#11 - TAG_TrcTaskName - UINT- 16#12 - TAG_TrcEveryNCycles - UINT- 16#13 - TAG_TrcBufferEntries - UINT- 16#14 - TAG_TrcPacketFlags - UINT- 16#15 - TAG_TrcTrigger - UINT- 16#86 - TAG_TrcTriggerLevel - UINT- 16#30 - TAG_TrcTriggerEdge - UINT- 16#31 - TAG_TrcTriggerUpdatesAfterTrigger - UINT- 16#34 - TAG_TrcTriggerFlags - UINT- 16#33 - TAG_TrcVariable - UINT- 16#83 - TAG_TrcVariableAddressFlag - UINT- 16#21 - TAG_TrcVariableAddressArea - UINT- 16#23 - TAG_TrcVariableAddressOffset - UINT- 16#24 - TAG_TrcVariableName - UINT- 16#20 - TAG_TrcVariableTypeClass - UINT- 16#25 - TAG_TrcVariableSize - UINT- 16#26 - TAG_TrcPacketHandle - UINT- 16#40 - TAG_TrcError - UINT- 16#FF7F - TAG_TrcGraphType - UINT- 16#27 - TAG_TrcGraphColor - UINT- 16#28 - TAG_TrcParameterId - UINT- 16#29 - TAG_TrcParameterModuleType - UINT- 16#30 - TAG_TrcParameterInstance - UINT- 16#31 - TAG_TrcActivateMinWarning - UINT- 16#32 - TAG_TrcCriticalLowerLimit - UINT- 16#33 - TAG_TrcMinWarningColor - UINT- 16#34 - TAG_TrcActivateMaxWarning - UINT- 16#35 - TAG_TrcCriticalUpperLimit - UINT- 16#36 - TAG_TrcMaxWarningColor - UINT- 16#37 - TAG_TrcSecondYAxis - UINT- 16#38 - TAG_TrcRecordHandle - UINT- 16#41 - TAG_TrcRecordConfiguration - UINT- 16#84 - TAG_TrcPacketTimestamp - UINT- 16#4A - TAG_TrcTraceStateStruct - UINT- 16#87 - TAG_TrcTraceState - UINT- 16#50 - TAG_TrcTraceStartTime - UINT- 16#51 - TAG_TrcTriggerState - UINT- 16#52 - TAG_TrcTriggerTimestamp - UINT- 16#53 - TAG_TrcTraceChangeTime - UINT- 16#55 - TAG_TrcRecordBuffer - UINT- 16#42 - TAG_TrcRecordResult - UINT- 16#47 - TAG_TrcCondition - UINT- 16#85 - TAG_TrcFileName - UINT- 16#4C 