Services (GVL)ΒΆ
- Attributes:
qualified_only- InOut:
Scope
Name
Type
Initial
Comment
Constant
SG_TraceManager
UINT16#F
Service Groups
SG_TrendStorage
UINT16#1E
SRV_TrendGetMinMaxTimestamps
UINT16#83
Trend storage services
SRV_TrendReadTrendData
UINT16#84
TAG_TrendApplicationName
UINT16#1
Tags for the requests
TAG_TrendPacketName
UINT16#2
TAG_TrendTimestamps
UINT16#3
TAG_TrendVariables
UINT16#4
TAG_TrendError
UINT16#1
Tags for the responses
TAG_TrendGetMinMaxTimestamps
UINT16#2
TAG_TrendCountVariables
UINT16#3
TAG_TrendReadTrendDataVariables
UINT16#85
TAG_TrendRelevantVariables
UINT16#86
SUBT_TrendReadTrendDataVariable
UINT16#5
TAG_TrendReadTrendDataTimestamps
UINT16#6
TAG_TrendReadTrendDataData
UINT16#7
SUBT_TrendRelevantVariable
UINT16#8
TAG_TrendReadTrendDataValidity
UINT16#9
TAG_TrendReadTrendDataPacket
UINT16#A
SUBT_TrendVariableDescription
UINT16#9
SUBT_TrendAttachedYAxis
UINT16#A
SUBT_TrendLineProperties
UINT16#B
SUBT_TrendAreaProperties
UINT16#C
SRV_TrcPacketCreate
UINT16#2
Trace manager services
SRV_TrcPacketDelete
UINT16#3
SRV_TrcPacketComplete
UINT16#4
SRV_TrcPacketOpen
UINT16#5
SRV_TrcPacketClose
UINT16#6
SRV_TrcPacketGetConfig
UINT16#9
SRV_TrcRecordAdd
UINT16#D
SRV_TrcPacketStart
UINT16#A
SRV_TrcPacketStop
UINT16#B
SRV_TrcPacketRead
UINT16#7
SRV_TrcPacketResetTrigger
UINT16#10
SRV_TrcPacketStore
UINT16#11
SRV_TrcPacketRestore
UINT16#12
SRV_TrcGetConfigFromFile
UINT16#13
TAG_TrcPacketName
UINT16#10
Tags for the requests
TAG_TrcPacketComment
UINT16#16
TAG_TrcAppName
UINT16#11
TAG_TrcTaskName
UINT16#12
TAG_TrcEveryNCycles
UINT16#13
TAG_TrcBufferEntries
UINT16#14
TAG_TrcPacketFlags
UINT16#15
TAG_TrcTrigger
UINT16#86
TAG_TrcTriggerLevel
UINT16#30
TAG_TrcTriggerEdge
UINT16#31
TAG_TrcTriggerUpdatesAfterTrigger
UINT16#34
TAG_TrcTriggerFlags
UINT16#33
TAG_TrcVariable
UINT16#83
TAG_TrcVariableAddressFlag
UINT16#21
TAG_TrcVariableAddressArea
UINT16#23
TAG_TrcVariableAddressOffset
UINT16#24
TAG_TrcVariableName
UINT16#20
TAG_TrcVariableTypeClass
UINT16#25
TAG_TrcVariableSize
UINT16#26
TAG_TrcPacketHandle
UINT16#40
TAG_TrcError
UINT16#FF7F
TAG_TrcGraphType
UINT16#27
TAG_TrcGraphColor
UINT16#28
TAG_TrcParameterId
UINT16#29
TAG_TrcParameterModuleType
UINT16#30
TAG_TrcParameterInstance
UINT16#31
TAG_TrcActivateMinWarning
UINT16#32
TAG_TrcCriticalLowerLimit
UINT16#33
TAG_TrcMinWarningColor
UINT16#34
TAG_TrcActivateMaxWarning
UINT16#35
TAG_TrcCriticalUpperLimit
UINT16#36
TAG_TrcMaxWarningColor
UINT16#37
TAG_TrcSecondYAxis
UINT16#38
TAG_TrcRecordHandle
UINT16#41
TAG_TrcRecordConfiguration
UINT16#84
TAG_TrcPacketTimestamp
UINT16#4A
TAG_TrcTraceStateStruct
UINT16#87
TAG_TrcTraceState
UINT16#50
TAG_TrcTraceStartTime
UINT16#51
TAG_TrcTriggerState
UINT16#52
TAG_TrcTriggerTimestamp
UINT16#53
TAG_TrcTraceChangeTime
UINT16#55
TAG_TrcRecordBuffer
UINT16#42
TAG_TrcRecordResult
UINT16#47
TAG_TrcCondition
UINT16#85
TAG_TrcFileName
UINT16#4C