Assert_LReal_Equal (FUN)¶
FUNCTION Assert_LReal_Equal : BOOL
Assertion function to check equality of two values of type
LREAL.The assertion succeeds for
(referenceValue - precision) <= actualValue AND (referenceValue + precision) >= actualValue- InOut:
Scope
Name
Type
Initial
Comment
Return
Assert_LReal_EqualBOOLTRUEif the assertion passes succesfully,FALSEotherwiseInput
contextThe instance of the test function block calling this function.This instance can be provided by usingTHIS^.referenceValueLREALThe expected value
actualValueLREALThe value to check
precisionLREAL0.0
A value to specify an allowed deviation. Default is 0.0
wsErrorMsgWSTRING(Constants.WSTRING_LENGTH)“”
A custom error message, that is added to the error message of the assertion itself.If this parameter is used, it is recommended to adapt the value of the library parameter Constants.WSTRING_LENGTH.