Assert_Real_NotEqual (FUN)¶
FUNCTION Assert_Real_NotEqual : BOOL
Assertion function to check unequality of two values of type
REALThe assertion passes for
(referenceValue - precision) > actualValue AND (referenceValue + precision) > actualValue- InOut:
Scope
Name
Type
Initial
Comment
Return
Assert_Real_NotEqualBOOLTRUEif the assertion passes succesfully,FALSEotherwiseInput
contextThe instance of the test function block calling this function.This instance can be provided by usingTHIS^.referenceValueREALThe reference value
actualValueREALThe value to check
precisionREAL0.0
A value to specify an allowed deviation. Default is 0.0
wsErrorMsgWSTRING(Constants.WSTRING_LENGTH)“”
A custom error message, that is added to the error message of the assertion itself.If this parameter is used, it is recommended to adapt the value of the library parameter Constants.WSTRING_LENGTH.