SysProcessExecuteCommand2 (FUN)¶
FUNCTION SysProcessExecuteCommand2 : DINT
- <description>Function to start a system command. The command is operating system dependent!
Command will be executed, only if allowed (see settings for details). Output of the executed command will be filled into pszStdOut.
</description> <result><p>RESULT: Number of bytes, read from the commands output.</p></result>
- InOut:
Scope
Name
Type
Comment
Return
SysProcessExecuteCommand2DINTInput
pszCommandREFERENCE TO STRING
<param name=”pszCommand” type=”IN”>Command line parameters to be transmitted to application at execution</param>
pszStdOutREFERENCE TO STRING
<param name=”pszStdOut” type=”IN”>Buffer for StdOut string</param>
udiStdOutLenUDINT<param name=”udiStdOutLen” type=”IN”>Buffersize for StdOut string buffer</param>
pResultPOINTER TO RTS_IEC_RESULT
<param name=”pResult” type=”OUT”>Pointer to runtime system error code. ERR_PARAMETER: if pszCommand, pszStdOut or udiStdOutLen is null, ERR_NO_ACCESS_RIGHTS: if command is not allowed</param>