SysDirRead (FUN)ΒΆ
FUNCTION SysDirRead : RTS_IEC_RESULT
Read next directory entry. Writes the entry in pszDirEntry.
- InOut:
- Scope - Name - Type - Comment - Return - SysDirRead- RTS_IEC_RESULT- Returns the runtime system error code (see CmpErrors.library) - ERR_OK: Entry could be read 
- ERR_END_OF_OBJECT: If end of directory list was reached 
- ERR_PARAMETER: If one of the parameters is invalid 
- ERR_BUFFERSIZE: If iMaxDirEntry is too short to get the complete directory entry string 
 - Note - Typically after error - ERR_BUFFERSIZE, the dir-handle is set to the next entry, so this entry will be missed!- Input - hDir- RTS_IEC_HANDLE- Handle to directory opened with SysDirOpen - Inout - szDirEntry- STRING- OUT_PARAMETER: Directory entry as string - Input - diMaxDirEntry- DINT- OUT_PARAMETER: Max number of bytes to write in pszDirEntry - pDirInfo- POINTER TO DirInfo - OUT_PARAMETER: Directory information NOTE: Can be 0 (so only directory name is provided in pszDirEntry) 