MC_MoveCircularRelative (FB)

FUNCTION_BLOCK FINAL MC_MoveCircularRelative

This function block commands a circular movement of an axis group to a relative position in the specified coordinate system.

The arc segment can be described in several ways, depending on the value of input CircMode.

In case of SMC_CIRC_MODE.BORDER or SMC_CIRC_MODE.CENTER, the auxiliary point is interpreted relative to the start position, too.

Note

The velocity/acc-/deceleration/jerk of each axis are properties of each axis and not specified within this function block. See also inputs VelFactor, AccFactor and JerkFactor.

InOut:

Scope

Name

Type

Initial

Comment

Inout

AxisGroup

AXIS_GROUP_REF_SM3

Reference to a group of axes

Input

Execute

BOOL

Start the motion at rising edge

CircMode

SMC_CIRC_MODE

Specifies the meaning of the inputs AuxPoint and CircDirection. See SMC_CIRC_MODE. The points are specified relatively, i.e. the perpendicular vector begins at the satrting point and ends in the spearhead point specified at the input signal AuxPoint.

AuxPoint

SMC_POS_REF

Auxiliary point in the specified coordinate system. The point is relative to the starting point. See CircMode.

EndPoint

SMC_POS_REF

End position in the specified coordinate system. The point is relative to the starting point.

PathChoice

MC_CIRC_PATHCHOICE

Choice of path: clockwise or counter-clockwise.

Velocity

LREAL

Maximum path velocity [u/s] for the coordinate system in which the path is defined. Always positive. Not necessarily reached.

Acceleration

LREAL

Maximum path acceleration [u/s²]. Always positive. Not necessarily reached.

Deceleration

LREAL

Maximum path deceleration [u/s²]. Always positive. Not necessarily reached.

Jerk

LREAL

Maximum path jerk [u/s³]. Always positive. Not necessarily reached.

CoordSystem

SMC_COORD_SYSTEM

Applicable coordinate system

BufferMode

MC_BUFFER_MODE

Defines the chronological sequence of the FB relative to the previous block.

TransitionMode

MC_TRANSITION_MODE

Defined the blending in case of a blending buffer mode

TransitionParameter

ARRAY [0..(SMC_RCNST.MAX_TRANS_PARAMS - 1)] OF LREAL

Parameters for blending

OrientationMode

SMC_ORIENTATION_MODE

Determines how the orientation is interpolated.

VelFactor

LREAL

1

The maximum velocity of each axis is multiplied by this factor, which must be in the range ]0, 1].

AccFactor

LREAL

1

The maximum acceleration of each axis is multiplied by this factor, which must be in the range ]0, 1].

JerkFactor

LREAL

1

The maximum jerk of each axis is multiplied by this factor, which must be in the range ]0, 1].

TorqueFactor

LREAL

1

The maximum torque of each axis is multiplied by this factor, which must be in the range ]0, 1]. A dynamic model must have been set using SMC_GroupSetDynamics for this factor to have an effect.

AdditionalAxes

IAdditionalAxesMovement

If an instance of SMC_MoveAdditionalAxesAbsolute or SMC_MoveAdditionalAxesRelative is assigned to this input, the additional axes of the axis group will perform the specified movement while this function block is active. Set to 0 if no additional axes movement has to be performed or if there are no additional axes.

Name

STRING

‘MC_MoveCircularRelative’

The name of the movement.

Output

Done

BOOL

Commanded end positions reached for all axes

Busy

BOOL

The FB is not finished

Active

BOOL

Indicates that the FB has control on the axis

CommandAborted

BOOL

Command is aborted by another command

CommandAccepted

BOOL

The command has been accepted by the axis group. If the output becomes TRUE, the function block instance can be used to command the next movement with a new rising edge on Execute. While the output is FALSE, keep calling the function block without a new rising edge of Execute. The output is reset to FALSE on a falling edge of Execute.

Error

BOOL

Signals that an error has occurred within the function block

ErrorID

SMC_ERROR

Error identification

MovementId

SMC_Movement_Id

The unique identifier of the movement. Valid if CommandAccepted or Done is TRUE.