SMC_ERROR (ENUM)¶
TYPE SMC_ERROR :
The enumeration SMC_ERROR contains all error numbers that can be returned by SoftMotion function blocks.
SMC_ErrorString generates an error string output.
- InOut:
Name
Initial
Comment
SMC_NO_ERROR
0
No error
SMC_DI_GENERAL_COMMUNICATION_ERROR
1
Communication error. The fieldbus slave is no longer in state operational.
SMC_DI_AXIS_ERROR
2
Axis error
SMC_DI_FIELDBUS_LOST_SYNCRONICITY
3
Fieldbus has lost synchronicity
SMC_DI_SWLIMITS_EXCEEDED
10
Position outside of permissible range of
SWLimitSMC_DI_HWLIMITS_EXCEEDED
11
Hardware end switch is active
SMC_DI_LINEAR_AXIS_OUTOFRANGE
12
This error occurs if a linear axis has more than 2^15 32-bit overflows of the position in increments
SMC_DI_HALT_OR_QUICKSTOP_NOT_SUPPORTED
13
Drive status
HaltorQuickstopis not supportedSMC_DI_VOLTAGE_DISABLED
14
Drive has no power
SMC_DI_IRREGULAR_ACTPOSITION
15
This error is no longer used
SMC_DI_POSITIONLAGERROR
16
Position lag error. Difference between set and current position exceeds the given limit
SMC_DI_HOMING_ERROR
17
Homing error reported by axis
SMC_DI_LICENSING_ERROR
18
A problem with the license occurred
SMC_REGULATOR_OR_START_NOT_SET
20
Controller enable not done or brake applied
SMC_WRONG_CONTROLLER_MODE
21
Axis in wrong controller mode
SMC_INVALID_ACTION_FOR_LOGICAL
25
Invalid action at logical axis
SMC_AXIS_IS_NOT_OPERATIONAL
27
Axis is not operational
wCommunicationState <> 100SMC_FB_WASNT_CALLED_DURING_MOTION
30
Motion creating module has not been called again before end of the motion
SMC_AXIS_IS_NO_AXIS_REF
31
Type of given
AXIS_REFvariable is notAXIS_REFSMC_AXIS_REF_CHANGED_DURING_OPERATION
32
AXIS_REFvariable has been exchanged while the module was active.SMC_FB_ACTIVE_AXIS_DISABLED
33
Axis disabled while being moved.
MC_Power.bRegulatorOnSMC_AXIS_NOT_READY_FOR_MOTION
34
Axis in its current state cannot execute a motion command, because the axis doesn’t signal currently that it follows the target values.
SMC_AXIS_ERROR_DURING_MOTION
35
The drive reported an error during an ongoing movement.
SMC_VD_MAX_VELOCITY_EXCEEDED
40
Maximum velocity
fMaxVelocityexceededSMC_VD_MAX_ACCELERATION_EXCEEDED
41
Maximum acceleration
fMaxAccelerationexceededSMC_VD_MAX_DECELERATION_EXCEEDED
42
Maximum deceleration
fMaxDecelerationexceededSMC_3SH_INVALID_VELACC_VALUES
50
Invalid velocity or acceleration values
SMC_3SH_MODE_NEEDS_HWLIMIT
51
Mode requests for safety reasons use of end switches.
SMC_FRC_NO_FREE_HANDLE
60
No free handle has been sent to open file.
SMC_MAC_INITIALIZATION_FAILED
65
Initialization of SMC_MultiAcyclicCommunicator not successful
SMC_MAC_INVALID_TASK_HANDLE
66
The axis has got an invalid handle
SMC_MAC_TOO_MANY_TASKS
67
Too many tasks with SDO-producing axes
SMC_MAC_ATOMIC_ADD_FAILED
68
Atomic add failed
SMC_SDO_INVALID_DATALENGTH
69
SDO-read lead to invalid datalength (> 4)
SMC_SCM_NOT_SUPPORTED
70
Mode not supported
SMC_SCM_AXIS_IN_WRONG_STATE
71
In current mode, controller mode cannot be changed.
SMC_SCM_INTERRUPTED
72
SMC_SetControllerModehas been interrupted byMC_Stoporerrorstop.SMC_ST_WRONG_CONTROLLER_MODE
75
Axis not in correct controller mode. Deprecated, no longer returned by
SMC_SetTorque.SMC_RAG_ERROR_DURING_STARTUP
80
Error at startup of the axis group
SMC_RAG_ERROR_AXIS_NOT_INITIALIZED
81
The axis is not yet in the required state.
SMC_PP_WRONG_AXIS_TYPE
85
The function block does not support virtual or logical axes.
SMC_PP_NUMBER_OF_ABSOLUTE_BITS_INVALID
86
The number of absolute bits is invalid, must be in the range 8 .. 32.
SMC_NEGATIVE_MODULO_PERIOD
87
The modulo period is negative, this is not supported.
SMC_CGR_ZERO_VALUES
90
Invalid values
SMC_CGR_DRIVE_POWERED
91
Gearing parameters must not be changed as long as the drive is under control.
SMC_CGR_INVALID_POSPERIOD
92
Invalid modulo period (<= 0 or greater than half the bus bandwidth)
SMC_CGR_POSPERIOD_NOT_INTEGRAL
93
The modulo period in increments is not an integer, but the modulo-handling is done by the drive.
SMC_P_FTASKCYCLE_EMPTY
110
Axis contain no information on cycle time (fTaskCycle = 0).
SMC_R_NO_ERROR_TO_RESET
120
Axis without error
SMC_R_DRIVE_DOESNT_ANSWER
121
Axis does not perform error-reset.
SMC_R_ERROR_NOT_RESETTABLE
122
Error could not be reset.
SMC_R_DRIVE_DOESNT_ANSWER_IN_TIME
123
Communication with the axis did not work.
SMC_R_CANNOT_RESET_COMMUNICATION_ERROR
124
If there is communication error, it cannot be reset
SMC_RP_PARAM_UNKNOWN
130
Parameter number unknown
SMC_RP_REQUESTING_ERROR
131
Error during transmission to the drives. See error number in function block instance
ReadDriveParameter.SMC_RP_DRIVE_PARAMETER_NOT_MAPPED
132
No assignment for drive parameters available
SMC_RP_PARAM_CONVERSION_ERROR
133
Conversion of the value to / from the drive parameters failed.
Unknown SoftMotion parameters
SMC_WP_PARAM_INVALID
140
Parameter number unknown or writing not allowed
SMC_WP_SENDING_ERROR
141
See error number in function block instance
WriteDriveParameterSMC_WP_DRIVE_PARAMETER_NOT_MAPPED
142
No assignment for drive parameters available
SMC_WP_PARAM_CONVERSION_ERROR
143
Conversion of the value to / from the drive parameters failed
Unknown SoftMotion parameters
SMC_H_AXIS_WASNT_STANDSTILL
170
Axis was not in standstill state.
SMC_H_AXIS_DIDNT_START_HOMING
171
Drive did not start homing.
SMC_H_AXIS_DIDNT_ANSWER
172
Drive did not reply, when homing was done.
SMC_H_ERROR_WHEN_STOPPING
173
Error at stop after homing. Deceleration may not be set.
SMC_H_AXIS_IN_ERRORSTOP
174
Drive is in errorstop status. Homing cannot be executed.
SMC_MS_UNKNOWN_STOPPING_ERROR
180
Unknown error at stop
SMC_MS_INVALID_ACCDEC_VALUES
181
Invalid velocity or acceleration values
SMC_MS_DIRECTION_NOT_APPLICABLE
182
Direction = shortest not applicable
SMC_MS_AXIS_IN_ERRORSTOP
183
Drive is in errorstop status. Stop cannot be executed
SMC_BLOCKING_MC_STOP_WASNT_CALLED
184
Instance of
MC_Stopblocking the axis byExecute=TRUEhas not been called yet. MC_Stop (Execute=FALSE) has to be called.SMC_MS_AXIS_ALREADY_STOPPING
185
Cannot interrupt an ongoing MC_Stop
SMC_UNKNOWN_TASK_INTERVAL
200
The task interval of the bus task could not be determined.
SMC_MA_INVALID_VELACC_VALUES
201
Invalid
velocityoraccelerationvaluesSMC_MA_INVALID_DIRECTION
202
Direction error
SMC_MR_INVALID_VELACC_VALUES
226
Invalid
velocityoraccelerationvaluesSMC_MR_INVALID_DIRECTION
227
Direction error
SMC_MAD_INVALID_VELACC_VALUES
251
Invalid
velocityoraccelerationvaluesSMC_MAD_INVALID_DIRECTION
252
Direction error
SMC_MSI_INVALID_VELACC_VALUES
276
Invalid velocity or acceleration values
SMC_MSI_INVALID_DIRECTION
277
Direction error
SMC_MSI_INVALID_EXECUTION_ORDER
278
Except from aborting, don’t call a major mvt-FB after
SMC_MoveSuperimposedSMC_LOGICAL_NO_REAL_AXIS
300
No longer used; only for compatibility
SMC_MV_INVALID_ACCDEC_VALUES
301
Invalid velocity or acceleration values
SMC_MV_DIRECTION_NOT_APPLICABLE
302
Direction=shortest/fastestnot applicableSMC_PP_ARRAYSIZE
325
Erroneous array size
SMC_PP_STEP0MS
326
Step time = t#0s
SMC_VP_ARRAYSIZE
350
Erroneous array size
SMC_VP_STEP0MS
351
Step time = t#0s
SMC_AP_ARRAYSIZE
375
Erroneous array size
SMC_AP_STEP0MS
376
Step time = t#0s
SMC_TP_TRIGGEROCCUPIED
400
Trigger already active
SMC_TP_COULDNT_SET_WINDOW
401
DriveInterface does not support the window function.
SMC_TP_COMM_ERROR
402
Communication error
SMC_AT_TRIGGERNOTOCCUPIED
410
Trigger already de-allocated
SMC_MCR_INVALID_VELACC_VALUES
426
Invalid velocity or acceleration values
SMC_MCR_INVALID_DIRECTION
427
Invalid direction
SMC_MCA_INVALID_VELACC_VALUES
451
Invalid velocity or acceleration values
SMC_MCA_INVALID_DIRECTION
452
Invalid direction
SMC_MCA_DIRECTION_NOT_APPLICABLE
453
Direction = fastest not applicable
SMC_SDL_INVALID_AXIS_STATE
475
SMC_ChangeDynamicLimitsmay only be called in state standstill. or power_off.SMC_SDL_INVALID_VELACC_VALUES
476
Invalid velocity, acceleration, deceleration or jerk values
SMC_CR_NO_TAPPETS_IN_CAM
600
Cam does not contain any tappets.
SMC_CR_TOO_MANY_TAPPETS
601
Tappet group ID exceeds
MAX_NUM_TAPPETSSMC_CR_MORE_THAN_32_ACCESSES
602
More than 32 accesses on one
CAM_REFSMC_CI_NO_CAM_SELECTED
625
No cam selected
SMC_CI_MASTER_OUT_OF_SCALE
626
Master axis out of valid range
SMC_CI_RAMPIN_NEEDS_VELACC_VALUES
627
Velocityandaccelerationvalues must be specified forramp_infunctionSMC_CI_SCALING_INCORRECT
628
Scaling variables
fEditor/TableMasterMin/Maxare not correctSMC_CI_TOO_MANY_TAPPETS_PER_CYCLE
629
Too many tappets became active during one cycle
SMC_CB_NOT_IMPLEMENTED
640
Function block for the given cam format is not implemented
SMC_GI_RATIO_DENOM
675
RatioDenominator= 0SMC_GI_INVALID_ACC
676
AccelerationinvalidSMC_GI_INVALID_DEC
677
DecelerationinvalidSMC_GI_MASTER_REGULATOR_CHANGED
678
Master changed regulator state (on -> off or off -> on) while coupling with slave was active.
SMC_GI_INVALID_JERK
679
JerkinvalidSMC_PH_INVALID_VELACCDEC
725
Velocityandacceleration/decelerationvalues invalidSMC_PH_ROTARYAXIS_PERIOD0
726
Rotation axis with
fPositionPeriod= 0SMC_NO_CAM_REF_TYPE
750
Type of given cam is not MC_CAM_REF.
SMC_CAM_TABLE_DOES_NOT_COVER_MASTER_SCALE
751
Master area,
xStartandxEnd, fromCamTableis not covered by curve data.SMC_CAM_TABLE_EMPTY_MASTER_RANGE
752
Cam data table has empty master range.
SMC_CAM_TABLE_INVALID_MASTER_MINMAX
753
Cam data master has invalid max-, min-values.
SMC_CAM_TABLE_INVALID_SLAVE_MINMAX
754
Cam data slave has invalid max-, min-values.
SMC_GIP_MASTER_DIRECTION_CHANGE
775
During coupling of slave axis, master axis has changed direction of rotation.
SMC_GIP_SLAVE_REVERSAL_CANNOT_BE_AVOIDED
776
Input
AvoidReversalis set, but slave reversal cannot be avoided.SMC_GIP_AVOID_REVERSAL_FOR_FINITE_AXIS
777
Input
AvoidReversalmust not be set for finite slave axes.SMC_GIP_MASTERSTARTDISTANCE_MUST_BE_ZERO_BUFFERED
778
If BufferMode is not Aborting, then MasterStartDistance must not be positive.
SMC_GIP_CANNOT_START_SYNC
779
The synchronisation cannot be started. This can happen when GearInPos is commanded as a buffered or blending movement and the master is in standstill when it becomes active.
SMC_BC_BL_TOO_BIG
800
Gear backlash
fBacklashtoo large (> position periode/2)SMC_QPROF_DIVERGES
825
Internal error: computation of quadratic trajectory failed
SMC_QPROF_INVALID_PARAMETER
826
Internal error: computation of quadratic trajectory failed
SMC_QPROF_NO_RESULT
827
Internal error: computation of quadratic trajectory failed
SMC_QPROF_INVALID_NEW_LBD
828
Internal error: computation of quadratic trajectory failed
SMC_QPROF_BAD_NEGOTIATION
829
Internal error: computation of quadratic trajectory failed
SMC_QPROF_INVALID_INTERVAL
830
Internal error: computation of quadratic trajectory failed
SMC_QPROF_NOT_ENOUGH_PHASES
831
Internal error: computation of quadratic trajectory failed
SMC_TG_INTERNAL_ERROR
832
Internal error: computation of quadratic trajectory failed
SMC_SRT_NOT_STANDSTILL_OR_POWEROFF
850
Action only permitted in
standstillorpower_off.SMC_SRT_INVALID_RAMPTYPE
851
Invalid ramp type
SMC_SMT_NOT_STANDSTILL_OR_POWEROFF
852
Action only permitted in
standstillorpower_off.SMC_SMT_INVALID_MOVEMENTTYPE_OR_POSITIONPERIOD
853
Invalid motion type or position period
SMC_SMT_AXIS_NOT_VIRTUAL
854
Function block only applicable to virtual axis.
SMC_NO_LICENSE
1000
Target is not licensed for CNC.
SMC_INT_VEL_ZERO
1001
Path cannot be processed because set
velocity = 0.SMC_INT_NO_STOP_AT_END
1002
Last object of path has end velocity <> 0.
SMC_INT_DATA_UNDERRUN
1003
Warning: GEOINFO-List processed inDataInbut end of list not reached.Reason:EndOfListof the queue inDataInnot be setSMC_Interpolatorfaster than path generating function blocks
SMC_INT_VEL_NONZERO_AT_STOP
1004
Velocity at Stop > 0
SMC_INT_TOO_MANY_RECURSIONS
1005
Too much
SMC_Interpolatorrecursions. SoftMotion errorSMC_INT_NO_CHECKVELOCITIES
1006
SMC_CheckVelocitiesis not the last processed function block, that accesses to the OutQueue-data bypoqDataIn.SMC_INT_PATH_EXCEEDED
1007
Internal or numeric error
SMC_INT_VEL_ACC_DEC_ZERO
1008
Velocityandacceleration/decelerationis null or to lowSMC_INT_DWIPOTIME_ZERO
1009
FB called with
dwIpoTime = 0SMC_INT_JERK_NONPOSITIVE
1010
Jerkinvalid becausejerkmust be positiveSMC_INT_QPROF_DIVERGES
1011
Internal error. Computation of the quadratic velocity profile does not converge.
SMC_INT_INVLALID_VELOCITY_MODE
1012
Invalid velocity mode
SMC_INT_TOO_MANY_AXES_INTERPOLATED
1013
More than the allowed number of axes has been interpolated. You are using a restricted version.
SMC_INT_DEGENERATE_SEGMENT
1014
The segment is numerically degenerate: It is very short and at the end of the queue. It should be ignored.
SMC_HIGH_CURVATURE_SPLINE
1015
Computation of interpolation point failed because the curvature of the spline is too high. Try changing the path to avoid sharp corners.
SMC_INT2DIR_BUFFER_TOO_SMALL
1050
Warning:
poqDataInofOutQueueis created too small. Adherence of stops not guaranteed.SMC_INT2DIR_PATH_FITS_NOT_IN_QUEUE
1051
Path does not go completely in queue.
SMC_XINT_INVALID_DIRECTION
1070
Direction input has an invalid value.
SMC_XINT_NOINTERSECTION
1071
Could not determine position on CNC path for the given x-position.
SMC_WAR_INT_OUTQUEUE_TOO_SMALL
1080
Warning:
poqDataInofOutQueueis created too small. Adherence of stops not guaranteedSMC_WAR_END_VELOCITIES_INCORRECT
1081
Warning: Final velocities inconsistent
SMC_CV_ACC_DEC_VEL_NONPOSITIVE
1100
Velocityandacceleration/decelerationvalues non-positiveSMC_CA_INVALID_ACCDEC_VALUES
1120
Values of
fGapVelocity/fGapAcceleration/fGapDecelerationnon-positiveSMC_TOK_INCOMPLETE_TOKEN_AT_END_OF_INPUT
1130
The input has been exhausted, but there is still an unfinished token
SMC_TOK_NOT_A_VALID_TOKEN
1131
The input does not match any token type
SMC_TOK_AMBIGUOUS_INPUT
1132
The input is ambiguous, it could be more than one token type
SMC_TOK_STRING_TOO_LONG_FOR_TOKEN
1133
The string is too long to be stored in a token. (Too long string literal, variable name or identifier?)
SMC_TOK_INVALID_NUMLIT
1134
Invalid number literal.
SMC_PRS_FUNC_DECL_TOO_FEW_ARGUMENTS
1150
Too less arguments provided for function inside G-Code
SMC_PRS_FUNC_DECL_TOO_MANY_ARGUMENTS
1151
Too many arguments provided for function inside G-Code
SMC_PRS_FUNC_DECL_WRONG_ARGUMENT_TYPE
1152
Check of argument types matching function declaration returned error
SMC_PRS_LOCAL_VAR_NOT_FOUND
1153
Could not find local variable on stack
SMC_PRS_INVALID_STRING
1154
Could not read string from token
SMC_PRS_TOO_MANY_CLOSING_BRACKETS
1155
Got more closing than opening brackets
SMC_PRS_TOO_MANY_OPENING_BRACKETS
1156
Got more opening than closing brackets
SMC_PRS_NO_SUCH_INFIX_OPERATOR
1157
Did not find infix-operator
SMC_PRS_NO_SUCH_PREFIX_OPERATOR
1158
Did not find prefix-operator
SMC_PRS_OPERATOR_INVALID_PRECEDENCE
1159
Got two operators with equal precedence but non-equal associativity
SMC_PRS_NOT_A_TERM
1160
Expected a valid term
SMC_PRS_EXPRESSION_INVALID_SEQUENCE
1161
Found invalid sequence of tokens inside expression
SMC_PRS_TOO_MANY_TERMS
1162
Got more terms than expected
SMC_PRS_STACK_OVERFLOW
1163
Could not parse an expression because the stack is too small
SMC_PRS_VAR_NAME_ALREADY_USED
1164
The name of a subprogram parameter or variable is already used for a different subprogram parameter or variable.
SMC_PRS_INCOMPLETE_SENTENCE_IN_TOKEN_QUEUE
1165
The input token queue of the g-code parser does not hold a complete g-code sentence.
SMC_PRS_TOO_MANY_SUBPROGRAMS
1167
The subprogram declaration could not be stored because the symbol table capacity has been exceeded.
SMC_PRS_TOO_MANY_SUBPROGRAM_PARAMETERS
1168
The maximum number of subprogram parameters has been exceeded.
SMC_PRS_SUBPROGRAM_LOOKUP_FAILED
1169
The lookup of the subprogram declaration failed. Maybe the subprogram name is incorrect, or the search path for subprograms is incomplete.
SMC_PRS_VAR_NOT_FOUND
1170
Did not find variable in symbol table
SMC_PRS_TOKEN_TYPE_UNKNOWN
1171
Token type unknown
SMC_PRS_GOT_NO_TERM
1172
No term after G-address
SMC_PRS_INVALID_VAR_TYPE
1173
Unknown variable type (not LREAL, BOOL, or STRING).
SMC_PRS_UNEXPECTED_TOKEN
1174
A token of a different type (e.g. an operator or identifier) was expected here.
SMC_PRS_ID3_EXPECTED
1175
An identifier with length three or longer was expected here.
SMC_PRS_ID_TOO_LONG
1176
The identifier is too long (more than 80 characters).
SMC_PRS_GADDRESS_EXPECTED
1177
A G-address (such as ‘G’, ‘F’, ‘X’) was expected here.
SMC_PRS_NWORD_EXPECTED
1178
An N-word (such as ‘N10’) was expected here.
SMC_PRS_NWORD_INVALID_SENTENCE_NUMBER
1179
The sentence number is not in the range [0, …, 16#FFFFFFFF].
SMC_PRS_NWORD_SENTENCE_NUMBER_NO_NUMBER_LITERAL
1180
The sentence number must be a number literal. (For example, expressions are not allowed.)
SMC_PRS_USE_OF_RESERVED_KEYWORD
1181
The identifier is a reserved keyword that cannot be used here.
SMC_PRS_SUBPROGRAMS_SIGNATURE_MISMATCH
1182
The subprogram declaration has already been read with a different signature or an error.
SMC_PRS_INITIAL_VALUE_HAS_WRONG_TYPE
1183
The initial value has the wrong type for this local variable
SMC_PRS_TOO_MANY_LOCAL_VARIABLES
1184
The maximum number of subprogram parameters has been exceeded.
SMC_PRS_SUBPROG_MUST_BE_FIRST_SENTENCE
1185
A subprogram declaration must be the first sentence in a g-code file.
SMC_PRS_ONLY_ONE_SUBPROGRAM_PER_FILE_ALLOWED
1186
Only one subprogram is allowed in a g-code file.
SMC_PRS_LET_AFTER_REGULAR_SENTENCE
1187
A LET declaration is not allowed after a regular g-code sentence.
SMC_PRS_UNMATCHED_END_SUBPROGRAM
1188
The END_SUBPROGRAM sentence is not matched by a subprogram declaration.
SMC_PRS_UNEXPECTED_TOKENS_AFTER_SUBPROGRAM
1189
After END_SUBPROGRAM, no more tokens are allowed.
SMC_PRS_MISSING_END_SUBPROGRAM
1190
A subprogram is not terminated by END_SUBPROGRAM.
SMC_DEC_ACC_TOO_LITTLE
1200
Accelerationvalue impermissibleSMC_DEC_RET_TOO_LITTLE
1201
Decelerationvalue impermissibleSMC_DEC_OUTQUEUE_RAN_EMPTY
1202
Data underrun. Queue has been read and is empty.
SMC_DEC_JUMP_TO_UNKNOWN_LINE
1203
Jump to line cannot be executed because line number is unknown.
SMC_DEC_INVALID_SYNTAX
1204
Syntax invalid
SMC_DEC_3DMODE_OBJECT_NOT_SUPPORTED
1205
Objects are not supported in 3D mode.
SMC_DEC_NEGATIVE_PERIOD
1206
Negative value as a period of additional axes invalid
SMC_DEC_DIMENSIONS_EXCLUSIVE_AU
1207
Not both axes A and U are interpolated. PA and PU are mutually exclusive.
SMC_DEC_DIMENSIONS_EXCLUSIVE_BV
1208
Not both axes B and V are interpolated. PB and PV are mutually exclusive.
SMC_DEC_DIMENSIONS_EXCLUSIVE_CW
1209
Not both axes C and W are interpolated. PC and PW are mutually exclusive.
SMC_DEC_DCS_NOT_ALL_OF_ABC_GIVEN
1210
For G54/G55/G56, either all of A,B,C or none must be given if orientation mode is not equal to SMC_ORI_CONVENTION.ADDAXES.
SMC_DEC_DCS_2D_NOT_IN_XY_PLANE
1211
The z-axis of the decoder CS must be equal to the z-axis of the machine CS.
SMC_DEC_CIRCLE_NON_UNIFORM_SCALING
1212
Scaling would distort commanded circle or ellipse.
SMC_DEC_ROTATION_AFFECTS_SCALING
1213
New relative rotation of the DCS (G55) would affect the scaling
SMC_DEC_DCS_NOT_ALL_OF_IJK_GIVEN
1214
For G54/G55/G56, either all of I,J,K or none must be given.
SMC_IPR_LOCAL_VAR_UNKNOWN_TYPE
1250
Local variable cannot be read due to invalid type
SMC_IPR_LVALUE_WRONG_TYPE
1251
The variable that’s supposed to be written on does not have the correct type.
SMC_IPR_EVAL_STACK_OVERFLOW
1252
Could not evaluate an expression because the evaluation stack is too small
SMC_IPR_NOT_A_NUMBER
1253
Numeric term became NaN
SMC_IPR_DIVISION_BY_ZERO
1254
Division by zero
SMC_IPR_INVALID_SCALING_FACTORS
1255
Invalid scaling factors
SMC_IPR_INTERPRETER_STACK_IMBALANCE
1256
On subprogram return, the interpreter stack ran empty. Internal error.
SMC_IPR_INTERPRETER_STACK_OVERFLOW
1257
The interpreter stack is too small. Too many local variables in the g-code or too many subprograms active.
SMC_IPR_INVALID_INTERPRETER_STACK_BUFFER
1258
The given buffer for the interpreter stack is either 0 or smaller than 1024 bytes.
SMC_IPR_BUFFER_TOO_SMALL
1259
The buffer for the outqueue is too small.
SMC_DNCCS_NO_DATA
1280
No data available at all
SMC_DNCCS_TOO_MANY_CALLSTACKS
1281
Too many different callstacks between current state of interpreter and iObjNo
SMC_DNCCS_INVALID_PROGRAM_INDEX
1282
Invalid program index
SMC_DNCCS_TOO_MANY_PROGRAMS
1283
Too many different programs
SMC_DNCCS_WRONG_TASK
1284
FB called in wrong task
SMC_GCV_BUFFER_TOO_SMALL
1300
Buffer too small
SMC_GCV_BUFFER_WRONG_TYPE
1301
Buffer elements have wrong type.
SMC_GCV_UNKNOWN_IPO_LINE
1302
Current line of the Interpolator could not be found.
SMC_CNC_INTERNAL_ERROR
1400
Internal error in CNC
SMC_PATH_MAX_HPOINTS_EXCEEDED
1401
The path element cannot hold H Switch points more than MAX_IPOSWITCHES. Adjust the switching points with different ‘O’ values or reduce the number of H points per path element.
SMC_TRC_G75_NOT_ALLOWED
1410
G75 not allowed during tool radius correction
SMC_TRC_QUEUE_FULL_NON_CARTESIAN
1411
Queue full, but no further cartesian element
SMC_TRC_SPLINE3D_5_NOT_SUPPORTED
1412
Tool radius correction does not support movement type SPLINE3D_5
SMC_TRC_PLANE_CHANGE_NOT_ALLOWED
1414
Plane change not allowed during tool radius correction
1450
The maximum nesting level for subprogram calls has been exceeded.
1451
A return statement from the main g-code program is not allowed.
1452
The declaration of a subprogram has not been found in the subprogram CNC file.
1453
The next g-code sentence could not be added to the output sentence queue because there was not enough space left.
SMC_NO_CNC_REF_TYPE
1500
Given CNC program is not of type
SMC_CNC_REFSMC_NO_OUTQUEUE_TYPE
1501
Given OutQueue is not of type
SMC_OUTQUEUESMC_GEOINFO_BUFFER_MISALIGNED
1502
4-byte aligned buffer part is not used in
pbyBufferSMC_3D_MODE_NOT_SUPPORTED
1600
Function block only works with 2D paths.
SMC_SAA_SMOOTHAREA_TOO_LARGE
1700
Range for smoothing too large
SMC_SAA_SP_INVALID_INPUT
1701
Invalid input
dSmoothingPart]0..1]SMC_SA_QUEUE_NOT_IN_BUFFER
1800
SMC_SegmentAnalyzerdetects thatOutQueuebuffer is full but not completed. The function block can only operate whenOutQueuefits the buffer completely.SMC_SA_QUEUE_CHANGED_DURING_OP
1801
OutQueuebuffer changed while the function block is operating on them.SMC_OS_INVALID_PARAMETER
1820
Invalid input value in dSplittingParameter
SMC_BSSP_IPO_NOT_ACTIVE
1830
Position cannot be saved. Interpolator is inactive
SMC_BS_SAVEDPOS_NOT_REACHED
1831
Saved position has not been found so far. It is probably on a different path.
SMC_BS_NO_POS_STORED
1832
Structure passed in ePos contains no saved position.
SMC_BlockSearchSavePosis not executed or in a wrong way.SMC_INVALID_FEATURE_FLAG
1900
Feature flag must be in the range {1, .., 31}.
SMC_SMB_HFUN_NOT_SUPPORTED
1901
Function block does not support h-functions.
SMC_SMB_ONLY_3DMODE
1902
Function block only works in 3D-Mode.
SMC_SMB_ERROR_COMPUTING_SPLINE
1903
Internal error computing the spline.
SMC_SMM_INVALID_PARAM_NUMBER
1910
wAdditionalParameter is too big
SMC_INVALID_PARAMETER
1950
The value of one of the inputs is invalid.
SMC_BLENDING_NOT_SUPPORTED_BY_PREVIOUS_MOVEMENT
1951
The previous movement does not support blending.
SMC_BUFFERED_NOT_SUPPORTED_BY_PREVIOUS_MOVEMENT
1952
The previous movement does not support buffered movements.
SMC_INHERIT_OWNER_ACTIVE_MOVEMENT_NOT_CALLED
1953
Cannot inherit owner because the active movement has not been not called yet in this cycle. Internal error.
SMC_MOVING_WITHOUT_ACTIVE_MOVEMENT
1954
The axis is moving but there is no active movement function block. Missing follow-up movement after movement that does not end in standstill?
SMC_BUFFER_MODE_NOT_SUPPORTED
1955
The configured BufferMode is not supported by the commanded movement.
SMC_ERROR_IN_A_PREVIOUS_MOVEMENT
1956
An error occured in a previous movement.
SMC_MORE_THAN_ONE_MOVEMENT_PER_INSTANCE
1957
Only one busy buffered/blending movement per FB instance is allowed.
SMC_RNCF_FILE_DOESNT_EXIST
2000
File does not exist
SMC_RNCF_NO_BUFFER
2001
No buffer allocated
SMC_RNCF_BUFFER_TOO_SMALL
2002
Buffer too small
SMC_RNCF_DATA_UNDERRUN
2003
Data underrun. Buffer has been read, is empty.
SMC_RNCF_VAR_COULDNT_BE_REPLACED
2004
Placeholder variable could not be replaced.
SMC_RNCF_NOT_VARLIST
2005
Input
pvldoes not point to aSMC_VARLISTobject.SMC_RNCF_NO_STRINGBUFFER
2006
Input
pStringBufferis not used or does not point to a variable of typeSMC_StringBufferSMC_RNCF_STRINGBUFFER_OVERRUN
2007
In the CNC program more different strings are used than the string buffer can hold.
SMC_RNCF_SUBPROGRAM_FILE_NOT_FOUND
2008
The file for a subprogram could not be found.
SMC_RNCQ_FILE_DOESNT_EXIST
2050
File could not be opened.
SMC_RNCQ_NO_BUFFER
2051
No buffer defined
SMC_RNCQ_BUFFER_TOO_SMALL
2052
Buffer too small
SMC_RNCQ_UNEXPECTED_EOF
2053
Unexpected end of file
SMC_ADL_FILE_CANNOT_BE_OPENED
2100
File could not be opened
SMC_ADL_BUFFER_OVERRUN
2101
Buffer overrun.
WriteToFilemust be called more frequently.SMC_RCAM_FILE_DOESNT_EXIST
2200
File could not be opened.
SMC_RCAM_TOO_MUCH_DATA
2201
Saved cam too big
SMC_RCAM_WRONG_COMPILE_TYPE
2202
Wrong compilation mode
SMC_RCAM_WRONG_VERSION
2203
File has wrong version
SMC_RCAM_UNEXPECTED_EOF
2204
Unexpected end of file
SMC_WDPF_CHANNEL_OCCUPIED
3001
This error is obsolete and is maintained only for compatibility. SMC_WDPF_TIMEOUT_PREPARING_LIST
SMC_WDPF_CANNOT_CREATE_FILE
3002
This error is obsolete and is maintained only for compatibility. File could not be created.
SMC_WDPF_ERROR_WHEN_READING_PARAMS
3003
This error is obsolete and is maintained only for compatibility. Error at reading the parameters.
SMC_WDPF_TIMEOUT_PREPARING_LIST
3004
This error is obsolete and is maintained only for compatibility. Timeout during preparing the parameter list.
SMC_ENC_DENOM_ZERO
5000
Nominator of the conversion factor
dwRatioTechUnitsDenomof the Encoder reference is 0SMC_ENC_AXISUSEDBYOTHERFB
5001
Other module trying to process motion on the Encoder axis
SMC_ENC_FILTER_DEPTH_INVALID
5002
Filter depth is invalid
SMC_INTERNAL_ERROR_INIT_MOVEMENT
6000
An internal error occurred during initialization of a new movement.
SMC_INVALID_AXIS_TYPE
6001
Invalid axis type, not finite or modulo (internal error)
SMC_PCCQ_POINTBUFFERTOOSMALL
10000
Buffer
pBuffertoo smallSMC_PCCQ_INPUTBUFFERFULLBUTNOTFINALIZED
10001
The function block must be applied to a path that fits completely in the buffer.
SMC_AXIS_GROUP_WRONG_STATE
11000
The axis group is in the wrong state for the requested operation.
SMC_AXIS_GROUP_TOO_MANY_AXES
11001
More than the maximum allowed number of axes has been added to an axis group.
SMC_AXIS_GROUP_INVALID_DYNLIMITS
11002
The dynamic limits of a single axis are invalid. (fSWMaxVelocity/Acceleration/Deceleration/Jerk)
SMC_AXIS_GROUP_INVALID_COORD_SYSTEM
11004
The given coordinate system is invalid for the requested operation
SMC_AXIS_GROUP_SINGLE_AXIS_ERROR
11005
An axis of the axis group is in state error
SMC_MOVE_INVALID_BUFFER_MODE
11006
The given buffer mode is not supported
SMC_MOVE_INVALID_DYNAMIC_FACTOR
11007
The dynamic factor is not in the range ]0 .. 1]
SMC_MOVE_INVALID_DYNAMICS
11008
The dynamic limits for the movement are invalid.
SMC_AXIS_GROUP_AXIS_NOT_PART_OF_GROUP
11009
The given axis is not part of the axis group.
SMC_AXIS_GROUP_NOT_SUPPORTED
11010
The requested operation is not supported
SMC_AXIS_GROUP_KINEMATICS_NOT_SET
11011
No kinematic configuration has been configured.
SMC_AXIS_GROUP_WRONG_NUMBER_OF_AXES
11012
The number of axes is not equal to the number of axes needed by the kinematic transformation
SMC_AXIS_GROUP_INTERRUPTED_BY_SINGLE_AXIS
11013
A coordinated movement has been interrupted by a single axis movement.
SMC_AXIS_GROUP_FOLLOW_SETVALUES
11014
An error occurred while following the computed set values.
SMC_AXIS_GROUP_TOO_MANY_DEPENDENCIES
11015
An axis group cannot depend on more than one master axis group.
SMC_AXIS_GROUP_MUTUAL_DEPENDENCY
11016
An axis group A may not depend on another axis group that depends on A.
SMC_AXIS_GROUP_DEPENDENCY_IN_DIFFERENT_TASK
11017
A dependant axis group must be executed in the same task.
SMC_AXIS_GROUP_AXIS_IN_DIFFERENT_TASK
11018
An axis belonging to an axis group must be executed in the same task.
SMC_AXIS_GROUP_PCS_STILL_IN_USE
11019
A second activation of the function block occurred while the PCS was still used by buffered motion commands.
SMC_AXIS_GROUP_CMD_ABORTED_DUE_TO_ERROR
11020
An error ocurred in a previous motion command.
SMC_AXIS_GROUP_INVALID_PARAMETER
11021
A parameter of an administrative function block is invalid.
SMC_AXIS_GROUP_UNSUPPORTED_RAMPTYPE
11022
One of the axes of the group uses an unsupported ramp type. Only trapez and quadratic are supported.
SMC_MOVE_INVALID_TRANSITION_PARAMETER
11023
invalid transition parameter
SMC_AXIS_GROUP_CPTR_CANNOT_FOLLOW
11025
CP-Tracking: Cannot keep the path; try to reduce the dynamics on the path and / or the dynamics when entering CP-Tracking.
SMC_AXIS_GROUP_CONTINUE_WRONG_POSITION
11026
Current position does not allow continuation. When continuing in a dynamic coordinate system (e.g. in a PCS that is following a rotary table), this error might be caused by not having used |SMC_GroupUpdateContinueData|.
SMC_AXIS_GROUP_CONTINUE_BUFFER_TOO_SMALL
11027
Buffer in continueData is too small; big external movement-queue-buffer in use.
SMC_AXIS_GROUP_CONTINUE_WRONG_CHECKSUM
11028
The checksum stored in the continue data is wrong. The continue data either was not written by MC_GroupInterrupt, or was modified afterwards.
SMC_AXIS_GROUP_IDLE_WAIT_AXES_MOVING
11029
Commanded SMC_GroupWait while axes were moving independently from the axis group (single axis movement or similar).
SMC_AXIS_INVERSE_TRAFO_EXCEEDING_POSLIMITS
11030
Inverse transformation lead to axis values exceeding the configured limits.
SMC_AXIS_GROUP_CANNOT_ADD_SAME_AXIS
11031
Prohibit adding the same axis to an axis group twice
SMC_AXIS_GROUP_TRANSFORMATION_NOT_SET
11032
No transformation is set.
SMC_AXIS_GROUP_NON_RESUMABLE_ERROR
11033
The path cannot be resumed after the current axis group error.
SMC_AXIS_GROUP_CONTINUE_DATA_NOT_WRITTEN
11034
The continue data for MC_GroupContinue has not been written correctly. (MC_GroupInterrupt not called / non-resumable axis group error)
SMC_ABC_AS_ACS_NOT_SUPPORTED_BY_KINEMATICS
11035
The configured kinematics does not support ABC_As_ACS
SMC_AXIS_GROUP_INVALID_INTERRUPT_POSITION
11036
The commanded interrupt position is invalid.
SMC_RELATIVE_MOVEMENT_TRACKING_CS
11037
The commanded relative movement is not supported. Its start position (end position of preceding movement) and distance are given in two different coordinate systems (CS) with at least one being dynamic
SMC_RELATIVE_MOVEMENT_ABORTING_TRACKING
11038
The commanded relative movement is not supported. It is Aborting and aborts a - track-in (from a static CS to a dynamic CS), - track-out (from a dynamic CS to a static CS) or - re-track (from a dynamic CS to another dynamic CS) movement.
SMC_CIRCULAR_MOVEMENT_TRACKING_CS
11039
The commanded circular movement is not supported. Its start position (end position of preceding movement) and target position are given in two different coordinate systems (CS) with at least one being dynamic.
SMC_CIRCULAR_MOVEMENT_ABORTING_TRACKING_CS
11040
The commanded aborting circular movement is not supported. Its start position (current position) and target position are given in two different coordinate systems (CS) with at least one being dynamic, or the aborted movement is PTP tracking.
SMC_AXIS_GROUP_CONTINUE_POSITION_WRONG_CHECKSUM
11041
The checksum of the continue position is wrong. The continue position either was not written by MC_GroupInterrupt, was modified afterwards, or an online change was executed when the continue position was still in use. Please note: The checksum is only checked when the continue position cannot be expressed as a constant value, because it changes with time (e.g. when a track in movement should be continued).
SMC_CIRCULAR_TRACKING_TOOL_CHANGE_NOT_SUPPORTED
11042
A circular movement with a tool change is only supported in a static coordinate system.
SMC_AXIS_GROUP_COULD_NOT_WRITE_CONTINUE_DATA
11043
Continue data could not be written. This can happen when trying to write continue data while moving to another continue position.
SMC_KERNEL_PTP_INTERNAL_ERROR
11100
Internal error in the kernel
SMC_KERNEL_PTP_INVALID_TASKCYCLETIME
11101
Task cycle time not positive
SMC_TRAFO_INVALID_PARAMETERS
12000
The parameter values of the transformation are invalid.
SMC_TRAFO_INVALID_CONSTELLATION
12001
The requested position is outside of the working area of the transformation.
SMC_TRAFO_INVALID_COUPLING
12002
The tool cannot work together with the positioning-part of the machine. Either, the positioning-part doesn’t implement ISMPositionKinematics2, or the tool cannot deal with the positioning’s image of orientations.
SMC_TRAFO_NOT_INITIALIZED
12003
The FB implements |ISMKinematicWithInitialization|, but hasn’t been Initialized yet.
SMC_TRAFO_NO_TOOL_WITH_OFFSET_ALLOWED
12004
Special error for positioning part of Kin_4Axis_Palletizer, which implements ISMPositionKinematics_Offset2, but cannot actually cope with offsets <> 0.
SMC_AXIS_GROUP_TOOL_OFFSET_INCOMPATIBLE_WITH_KINEMATICS
12005
The configured tool offset is not compatible with the kinematics used
SMC_TRAFO_INVALID_AXIS_LIMITS
12006
The configured position limits of one or more axes are not valid for the kinematics.
SMC_AXIS_GROUP_PATH_DEVIATION_TOO_HIGH
12007
The path deviation is higher than the allowed tolerance. When tracking is used, this indicates that the tracked object is accelerating/ decelerating too quickly for the robot to follow. See
SMC_SetPathTolerance.SMC_AXIS_POSITION_EXCEEDS_POSLIMITS
12008
The given axis position exceeds the position limits of an axis.
SMC_CP_CACHE_FULL
12100
The cache of the CP planner is too small.
SMC_CP_EVAL_ERROR
12101
The evaluation of the position on a path element failed (internal error).
SMC_CP_NON_CONTINUABLE_STATE
12102
Non-continuable state reached (internal error).
SMC_CP_MAX_LENGTH_EXCEEDED
12103
Maximum trajectory length exceeded (internal error).
SMC_CP_ACCELERATION_TOO_HIGH
12104
Path acceleration too high (invalid state, internal error).
SMC_CP_MAX_ITERATIONS_EXCEEDED
12105
Maximum number of iterations exceeded (internal error).
SMC_CP_NO_TRAJECTORY
12106
No trajectory could be computed (internal error).
SMC_CP_OUT_QUEUE_FULL
12107
The out-queue is full (internal error).
SMC_CP_QUEUE_UNDERRUN
12108
Queue underrun: no element left in queue.
SMC_CP_INVALID_QUEUE
12109
Invalid queue (invalid size or pointer)
SMC_CP_BLENDING_INTERNAL_ERROR
12110
An internal error occurred while blending two CP movements
SMC_CP_CIRCLE_COLLINEAR_POINTS
12111
The three points that define the circle are collinear.
SMC_CP_CIRCLE_CENTER_NOT_ON_BISECTOR
12112
The center point is not on the perpendicular bisector of the start and end point.
SMC_CP_CIRCLE_RADIUS_ZERO
12113
The radius is zero
SMC_CP_CIRCLE_DISTANCE_LARGER_THAN_DIAMETER
12114
The distance between start and end point is larger than the diameter. (When trying to create a circle using
SMC_Circ_Mode.Radius.)SMC_CP_CIRCLE_START_AND_ENDPOINT_EQUAL
12115
The start and end point are equal (
SMC_Circ_Mode.Radius).SMC_CP_BLENDING_DEGENERATE_SPLINE
12116
The blending spline is degenerate (too short or non-regular)
SMC_CP_ELEMENT_TOO_SHORT
12117
The path element cannot be created because it is too short.
SMC_CP_COULD_NOT_CUT_PATH
12118
The path could not be cut for aborting movement (internal error).
SMC_CP_INVALID_ANGULAR_VEL_ACC
12119
The given angular velocity or acceleration is invalid (quaternion with non-zero real part, internal error).
SMC_CP_INVALID_ORIENTATION
12120
The given orientation is invalid (non-orthonormal matrix or non-unit quaternion, internal error).
SMC_CP_TIME_BUDGET_EXCEEDED
12121
The given time budget for the computation is exceeded (internal error).
SMC_AXIS_GROUP_AXIS_LIMIT_VIOLATED
12122
A limit of an axis has been violated. This can happen if a CP movement is done too close to a singularity or if the path has a very high curvature.
SMC_CP_CONFIGS_DIFFER
12125
The kinematic configuration of the start position differs from the end position. The CP movement would pass a singularity.
SMC_CP_BUS_TASK_NOT_CALLED
12126
This error is obsolete and is maintained only for compatibility. If a CP-halt/-stop is commanded, some information has to be transferred to the bus task. We expect this to happen before the next cycle of the slow task.
SMC_CP_NO_ROOT_IN_INTERVAL_FOUND
12127
The stop trajectory could not be found in the interval. (internal error)
SMC_CP_KIN_DOES_NOT_SUPPORT_AXIS_ORIENTATION_IPO
12128
The kinematics does not support the orientation mode “Axis” for continuous path movements.
SMC_CP_AXIS_ORIENTATION_IPO_NOT_SUPPORTED_FOR_CPTR
12129
The axis orientation interpolation mode is not supported for CP movements with a dynamic PCS (tracking).
SMC_CP_INVALID_PATH_ELEM
12130
An invalid path element has been created (internal error)
SMC_CP_TRANSITION_NOT_SMOOTH
12131
The transition between two path elements is not G2 continuous, and there is no stop (internal error)
SMC_CP_AXIS_ORIENTATION_IPO_CONFIG_DIFFERS
12132
Axis orientation interpolation mode is used, but between the start end end position, there is a singularity of the position kinematics.
SMC_CP_AXIS_ORIENTATION_IPO_OFFSET2_NOT_IMPLEMENTED
12133
The position kinematics has configurations but does not implement the interface ISMPositionKinematics_Offset2. In this case, axis orientation interpolation is not possible.
SMC_CP_ROTARY_AXIS_PERIOD_MISMATCH
12134
The target position of a rotary axis will not be reached in the commanded period. (E.g. the commanded target position is -170°, but the target will be reached with position 190° instead.) This means that the chosen interpolation to the target position is not compatible with the commanded position. For PTP movements (MC_MoveDirect*), this error can happen if the previous movement is a CP movement (MC_MoveLinear*, MC_MoveCircular*), and if the CP movement is very long. To avoid the problem, the CP movement should be divided into two or more shorter movements. The problem can occur if a rotary axis has to move 360° or more during the CP movement.
SMC_CP_ROTARY_AXIS_RANGE_VIOLATION
12135
A rotary axis has violated the allowed axis range during a CP movement. The CP movment is not in the working area.
SMC_CP_COMPUTE_TARGET_DISCONTINUITY
12136
The target trajectory could not be computed due to a discontinuity of the end position (internal error).
SMC_CP_TRAJECTORY_NOT_SMOOTH
12137
The trajectory is not smooth, the phase end states do not equal the the current state (internal error).
SMC_CP_ERROR_CREATING_PARAM_TRANSFORM
12138
A parameter transformation could not be created (internal error).
SMC_CP_PTP_DATA_NUMBER_OF_AXES
12139
Error generating path-invariant PTP element (internal error).
SMC_CP_NEGATIVE_PATH_VELOCITY
12140
Error while computing a new trajectory: the path velocity after phase 1 (positive jerk of length dTau1) is negative (internal error).
SMC_CP_TRANSITIONING_FROM_SINGLE_AXIS_MOVEMENT_NOT_SUPPORTED
12141
Transitioning from a single axis movement to a continuous path movement is not supported.
SMC_CP_PLANNER_NO_PROGRESS
12142
The CP-planner did not make any progress. This is an internal error That can be triggered by very sharp corners (e.g. blending between short elements or with small corner distance).
SMC_CP_INTERNAL_EVAL_CACHE_ERROR
12143
Internal error in the evaluation cache of the CP-planner.
SMC_GROUPJOG2_MAX_DISTANCE_NON_POSITIVE
12200
Either MaxLinearDistance or MaxAngularDistance of SMC_GroupJog2 is non-positive.
SMC_MOVEMENT_INTERNAL_ERROR
13001
Internal error in a movement.
SMC_MOVEMENT_GET_POS_INTERNAL_ERROR
13002
Internal error while trying to get a position in a movement.
SMC_CPTR_INTERNAL_ERROR
13003
Internal error in the CPTR kernel.
SMC_CP_IPO_INTERNAL_ERROR
13004
Internal error while interpolating in the CP kernel.
SMC_CP_ADD_NEW_MOVEMENT_INTERNAL_ERROR
13005
Internal error while adding a new movement to the CP kernel.
SMC_AXIS_GROUP_COORDINATION_INTERNAL_ERROR
13006
Internal error while coordinating kernels.
SMC_AXIS_GROUP_ADD_MOVEMENT_INTERNAL_ERROR
13007
Internal error while adding movements to the axis group.
SMC_AXIS_GROUP_READ_AXIS_STATES_INTERNAL_ERROR
13008
Internal error while reading the state of one of the group’s axes.
SMC_AXIS_GROUP_READ_VEL_INTERNAL_ERROR
13009
Internal error while trying to read the velocity.
SMC_AXIS_GROUP_READ_ACC_INTERNAL_ERROR
13010
Internal error while trying to read the acceleration.
SMC_AXIS_GROUP_INVALID_STATE_INTERNAL_ERROR
13011
Internal error: The axis group is in an invalid state.
SMC_AXIS_GROUP_PCS_INTERNAL_ERROR
13012
Internal error while handling a PCS.
SMC_AXIS_GROUP_INTERRUPT_INTERNAL_ERROR
13013
An internal error occured during an interrupt.
SMC_CONTINUE_DATA_READ_INTERNAL_ERROR
13014
Internal error while reading continue data.
SMC_CONTINUE_DATA_WRITE_INTERNAL_ERROR
13015
Internal error while writing continue data.
SMC_PATH_ELEM_INTERNAL_ERROR
13016
Internal error in a path element.
SMC_PATH_ELEM_ESTIMATE_LIMITS_INTERNAL_ERROR
13017
Internal error while estimating the limits of a path element.
SMC_PATH_ELEM_ZERO_LEN_INTERNAL_ERROR
13018
Internal error in a zero-length path element.
SMC_PATH_ELEM_BLEND_INTERNAL_ERROR
13019
Internal error in a blending element.
SMC_PATH_ELEM_BLEND_GEO_INTERNAL_ERROR
13020
Internal error in the geometric part of a path element.
SMC_PATH_ELEM_BLEND_ORI_INTERNAL_ERROR
13021
Internal error in the orientation part of a path element.
SMC_PATH_ELEM_BLEND_AS_INTERNAL_ERROR
13022
Internal error in an axis space element.
SMC_ELEM_FUN_CART_INTERNAL_ERROR
13023
Internal error in an element function.
SMC_CP_HALT_STOP_INTERNAL_ERROR
13024
Internal error during cp halt or stop.
SMC_TRJ_PLANNING_INIT_INTERNAL_ERROR
13025
Internal error while initializing trajectory planning.
SMC_TRJ_PLANNING_GEN_SAMPLES_INTERNAL_ERROR
13026
Internal error while generating samples.
SMC_TRJ_PLANNING_PATH_OUT_INTERNAL_ERROR
13027
Internal error while creating the output path.
SMC_TRJ_PLANNING_EVAL_AXIS_INTERNAL_ERROR
13028
Internal error while evaluating axis values.
SMC_TRJ_PLANNING_LOOKAHEAD_INTERNAL_ERROR
13029
Internal error in planning lookahead.
SMC_AXIS_GROUP_READ_JERK_INTERNAL_ERROR
13030
Internal error while trying to read the jerk.
SMC_AXIS_GROUP_WRITE_CONTINUE_POS_INTERNAL_ERROR
13031
Internal error while writing the continue position.
SMC_CP_TRANSITION_CHECK_FAILED
13032
Internal error while checking whether the path is continuous.
SMC_ABORTING_INTERNAL_ERROR
13033
Internal error while aborting.
SMC_LINE_TO_REL_STANDSTILL_INTERNAL_ERROR
13034
Internal error while creating a line to relative standstill.
SMC_PATH_ELEM_POSE_EVAL_INTERNAL_ERROR
13035
Internal error while evaluating a pose on a path element.