SMC_GCodeJumpBuffer (FB)¶
FUNCTION_BLOCK SMC_GCodeJumpBuffer
- InOut:
- Scope - Name - Type - Initial - Comment - Inout - ncprogIn- CNC program input - Input - bExecute- BOOL- Rising edge starts operation. - pBuffer- POINTER TO SMC_GCODE_WORD - Memory for internal buffer - dwBufferSize- UDINT- Size of - pBuffer- pBufferOut- POINTER TO SMC_GCODE_WORD - Memory for - ncprogOut- dwBufferOutSize- UDINT- Size of - pBufferOutin byte- historyBuffer- A function block keeping track of all G-Code sentence numbers that have been processed and removed from the jump buffer. If no buffer is provided, the default implementation SMC_MonotoneSentenceHistory will be used. - udiRefillWindowSizePercentage- UDINT- 10 - The amount of elements that is read and removed in one cycle and added in the next cycle, when no jump has been requested (if - ncprogOut.bRestart=FALSE). Provided in percent of the current buffer level and defaults to a minimum value of 10. A larger center window will slightly improve reading performance for long cycle times, while reducing the buffer’s chances to have a requested jump target actually buffered.- Output - bBusy- BOOL- bDone- BOOL- bError- BOOL- ErrorID- SMC_ERROR- ncprogOut- CNC program output to SMC_NCDecoder - bExecuteDecoder- BOOL- Set to - TRUEas soon as- ncprogOutis filled sufficiently to be interpreted by SMC_NCDecoder;
Structure: