SMC_ReadNCFile (FB)¶
FUNCTION_BLOCK SMC_ReadNCFile
SMC_ReadNCFile can read a NC-ASCII-file from the file system of
the controller in order to make it available for the SMC_NCDecoder.
Thus, a NC program can be read in and decoded at runtime.
Note
This function block has been superseeded by SMC_ReadNCFile2 and is kept only for compatibility. It is recommended to use SMC_ReadNCFile2, which has additional features like mathematical expressions or sub programs in g-code
- InOut:
- Scope - Name - Type - Initial - Comment - Input - bExecute- BOOL- Rising edge: Starts execution. While - TRUE, the function block is active.- sFileName- STRING(255)- ‘’ - File path - pvl- POINTER TO SMC_VARLIST - If there aren’t variables in the CNC programm, this input isn’t set. SMC_VARLIST - pBuffer- POINTER TO BYTE - Pointer on a sufficiently large, free data area (buffer) that is allocated in the IEC application. It is strongly recommended to allocate the buffer as - ARRAY[0..x] OF |ioSMC_GCODE_WORD|in order to make sure to have a correct data alignment. A definition of- ARRAY[0..x] OF BYTEmay lead to a misaligned data access on some platforms.- dwBufferSize- DWORD- Size of the buffer in byte - fDefaultVel- LREAL- Default velocity; used if velocity is not specified inside the CNC file. - fDefaultAccel- LREAL- Default acceleration; used if acceleration is not specified inside the CNC file - fDefaultDecel- LREAL- Default deceleration used if deceleration is not specified inside the CNC file - fDefaultVelFF- LREAL- Default velocity for fast forward (G0), FF word. It is used if no velocity is specified inside the CNC file. - fDefaultAccelFF- LREAL- Default acceleration for fast forward (G0), EF+ word. It is used if no acceleration is specified inside the CNC file. - fDefaultDecelFF- LREAL- Default deceleration for fast forward (G0), EF- word. A non- negative value is expected used if no deceleration is specified inside the CNC file. - b3DMode- BOOL- If - TRUE, a G17 command (activation 3D-mode) is executed implicitly.- pStringBuffer- POINTER TO SMC_StringBuffer - Pointer to an object of type SMC_StringBuffer. This object is used to store strings that are defined in the G-code program in order to write them to variables using G36&37. If the pointer is not set (0) and string constants are used in the G-code program, an error will be generated.( - SMC_RNCF_NO_STRINGBUFFER).- bEnableSyntaxChecks- BOOL- Turns on syntax checks that will detect invalid G-code and stop with an error in this case - Output - bDone- BOOL- TRUEif parameter is available- bBusy- BOOL- TRUEwhile execution of function block is not finished- bError- BOOL- TRUEsignals that an error has occurred within the function block.- ErrorID- SMC_ERROR- Error identification, - SMC_ERROR- bExecuteDecoder- BOOL- Signal for triggering the input Execute of the SMC_NCDecoder module. - ncprog- STRUCT(nElements := 0) - CNC program, input of the succeeding SMC_NCDecoder module. - dwFileSize- DWORD- Size of the file in bytes. - dwPos- DWORD- Current Position of the cursor in the file. 