SMC_FollowSetValues (FB)¶
FUNCTION_BLOCK SMC_FollowSetValues
Writes set values to the axis without doing any checks.
- InOut:
- Scope - Name - Type - Comment - Inout - Axis- Reference to the axis - Input - bExecute- BOOL- Rising edge: Starts the execution of the function block. - bAbort- BOOL- Abort the execution of the function block (e.g. in order to avoid an error when restarting with a different axis) - dwValueMask- DWORD- Values, which are written to the axis ( - TRUE) and which are ignored (- FALSE):- Bit0: - fSetPosition
- Bit1: - fSetVelocity
- Bit2: - fSetAcceleration
- Bit3: - fSetJerk
- Bit4: - fSetTorque
- Bit5: - fSetCurrent
 - fSetPosition- LREAL- Set position in [u] - fSetVelocity- LREAL- Set velocity in [u/s] - fSetAcceleration- LREAL- Set acceleration in [u/s²] - fSetJerk- LREAL- Set jerk in [u/s³] - fSetTorque- LREAL- Set torque/force in [Nm]/[N] - fSetCurrent- LREAL- Set current in [A] - Output - bBusy- BOOL- TRUE: Execution of function block has not been finished.- bCommandAborted- BOOL- TRUE: Command has been aborted by another command.- bError- BOOL- TRUE: Error has occurred within the function block.- iErrorID- SMC_ERROR- Error identification 