RDT_Base.SetTLSContext (METH)ΒΆ
METHOD SetTLSContext : NBS.ERROR
Sets all the data neccessary to handle encrypted tcp connections
- InOut:
- Scope - Name - Type - Initial - Comment - Return - SetTLSContext- NBS.ERROR- Input - xUseCert- BOOL- If the certificate is used or not - psUseCaseName- POINTER TO STRING - A name to identify this context in the security manager, the name can be completely user defined - ePurpose- NBS.PURPOSE- This context can be used on the server side or on the client side. - psTLSVersion- POINTER TO STRING - A string to select the correct protocol version - psCipherList- POINTER TO NBS.CIPHER_LIST A string to select the correct encryption cipher suites.- psHostname- POINTER TO STRING - A hostname to select the correct certificate on the server side. - udiVerificationMode- UDINT1 => No peer verification2 => Active Peer verification(4) => 2+4 = 6 => Force termination, if no client certificate(8) => 2+8=10 or 2+4+8 = 14 => Request client certificate only whithin initial handshake- psCertCommonName- POINTER TO STRING - A string to select the correct certificate in local certificate store It can be empty in case of an external cert handle is passed - hCert- RTS_IEC_HANDLE- RTS_INVALID_HANDLE - External cert handle to use. Exclusive use vs cert name - itfCertVerifer- NBS.ICertificateVerifier- A callback for application specific certificate verification 