RecipeManCommands.SetRecipeValues (METH)ΒΆ
METHOD SetRecipeValues : DWORD
Sets the recipe values of the corresponding recipe
Example:
We have 50 recipe values. We want to create a table which sets 10 recipe values at the same time.
We define a string array strArr: ARRAY[0..9] OF STRING;
Corresponding to the iStartIndex we can set the recipe values from a specific area.
StartIndex:= 0; The values 0..9 are set.
iStartIndex:= 20; The values 20..29 are set.
- In this example:
- iSize:= 10;
 
- InOut:
- Scope - Name - Type - Comment - Return - SetRecipeValues- DWORD- Possible last error values: - See ReturnValues (GVL) for a description of all possible errors. - Inout Const - RecipeDefinitionName- STRING- Name of the recipe definition - RecipeName- STRING- Name of the recipe - Input - pStrings- POINTER TO ARRAY [0..0] OF STRING - The strings with the recipe values - iSize- INT- Size of the string array. - iStartIndex- INT- Start index. Can be used for a scrolling function (see example) 
