RecipeManCommands.GetRecipeNames (METH)ΒΆ
METHOD GetRecipeNames : DWORD
Returns the recipe names from the corresponding recipe definition
Example:
We have 50 recipes. We want to create a table which shows 10 recipe names at the same time.
We define a string array strArr: ARRAY[0..9] OF STRING;
Corresponding to the iStartIndex we can get the recipe names from a specific area.
StartIndex:= 0; The names 0..9 are returned.
iStartIndex:= 20; The names 20..29 are returned.
In this example:
iSize:= 10;
- InOut:
- Scope - Name - Type - Comment - Return - GetRecipeNames- DWORD- Possible last error values: - See ReturnValues (GVL) for a description of all possible errors. - Input - RecipeDefinitionName- STRING- Name of the recipe definition - pStrings- POINTER TO ARRAY [0..0] OF STRING - The strings were the recipe values should be stored - iSize- INT- Size of the string array - iStartIndex- INT- Start index. Can be used for a scrolling function (see example) 