GCL (GVL)ΒΆ
- InOut:
- Scope - Name - Type - Initial - Comment - Constant - IODIRA - USINT- 16#0 - Data Direction Register for PORTA - IODIRB - USINT- 16#1 - Data Direction Register for PORTB - IPOLA - USINT- 16#2 - Input Polarity Register for PORTA - IPOLB - USINT- 16#3 - Input Polarity Register for PORTB - GPINTENA - USINT- 16#4 - Interrupt-on-change enable Register for PORTA - GPINTENB - USINT- 16#5 - Interrupt-on-change enable Register for PORTB - DEFVALA - USINT- 16#6 - Default Value Register for PORTA - DEFVALB - USINT- 16#7 - Default Value Register for PORTB - INTCONA - USINT- 16#8 - Interrupt-on-change control Register for PORTA - INTCONB - USINT- 16#9 - Interrupt-on-change control Register for PORTB - IOCON - USINT- 16#A - Configuration register for device - GPPUA - USINT- 16#C - 100kOhm pullup resistor register for PORTA (sets pin to input when set) - GPPUB - USINT- 16#D - 100kOhm pullup resistor register for PORTB (sets pin to input when set) - INTFA - USINT- 16#E - Interrupt flag Register for PORTA - INTFB - USINT- 16#F - Interrupt flag Register for PORTB - INTCAPA - USINT- 16#10 - Interrupt captured value Register for PORTA - INTCAPB - USINT- 16#11 - Interrupt captured value Register for PORTB - GPIOA - USINT- 16#12 - General purpose I/O Register for PORTA - GPIOB - USINT- 16#13 - General purpose I/O Register for PORTB - OLATA - USINT- 16#14 - Output latch Register for PORTA - OLATB - USINT- 16#15 - Output latch Register for PORTB 