GCL (GVL)ΒΆ
- InOut:
Scope
Name
Type
Initial
Comment
Constant
IODIRA
USINT16#0
Data Direction Register for PORTA
IODIRB
USINT16#1
Data Direction Register for PORTB
IPOLA
USINT16#2
Input Polarity Register for PORTA
IPOLB
USINT16#3
Input Polarity Register for PORTB
GPINTENA
USINT16#4
Interrupt-on-change enable Register for PORTA
GPINTENB
USINT16#5
Interrupt-on-change enable Register for PORTB
DEFVALA
USINT16#6
Default Value Register for PORTA
DEFVALB
USINT16#7
Default Value Register for PORTB
INTCONA
USINT16#8
Interrupt-on-change control Register for PORTA
INTCONB
USINT16#9
Interrupt-on-change control Register for PORTB
IOCON
USINT16#A
Configuration register for device
GPPUA
USINT16#C
100kOhm pullup resistor register for PORTA (sets pin to input when set)
GPPUB
USINT16#D
100kOhm pullup resistor register for PORTB (sets pin to input when set)
INTFA
USINT16#E
Interrupt flag Register for PORTA
INTFB
USINT16#F
Interrupt flag Register for PORTB
INTCAPA
USINT16#10
Interrupt captured value Register for PORTA
INTCAPB
USINT16#11
Interrupt captured value Register for PORTB
GPIOA
USINT16#12
General purpose I/O Register for PORTA
GPIOB
USINT16#13
General purpose I/O Register for PORTB
OLATA
USINT16#14
Output latch Register for PORTA
OLATB
USINT16#15
Output latch Register for PORTB