ProfinetConstants (PARAMS)ΒΆ
- Attributes:
- qualified_only
- InOut:
- Scope - Name - Type - Initial - Comment - Constant - MAX_SLAVES - UINT- 128 - MAX_SCAN_SLAVES - UINT- 128 - MAX_SCAN_BUFFER_SIZE - UINT- (1024 * 10) - MAX_PARALLEL_CONNECT - UINT- 6 - MaxAlarmDataLength - UINT- (MaxAlarmPayloadLength + 26) - Maximal size of the AlarmNotification-PDU accepted by the AlarmEndpoint (200 = 0xC8 is Mandatory) - MaxAlarmPayloadLength - UINT- 16#C8 - CommFB.MaxAlarmDataLength(198) + 2 Byte USI = 200 - RemoteApplicationReadyTimeout - TIME- TIME#5m0s0ms - PN-Services: Remote Application Ready Timeout = 300 s - MAX_PORTS - DINT- 8 - MAX_ADAPTER_INFO - DINT- 8 - MAX_RECORD_DATA - UINT- (16588 + 24) - CDS-72975 Enable Automated Testcases (Certification) - MAX_ETHERNET_BUFFER - DINT- 64 - MAX_ServicePDU_SIZE : UINT := ProfinetConstants.MAX_RECORD_DATA * 4 + 64 + 20; //e.g. connect req - RTATimeoutFactor - UINT- 1 - RTATimeout = RTATimeoutFactor * 100 ms 1 : Default (100ms), 1 up to 100 mandatory - RTARetries - UINT- 3 - RTARetries (Default = 3), 3-15 Mandatory - MaxNumForwardedIPPackets - UDINT- 32 - Maximum number of ip packets forwarded cyclically from the ip stack to the network adapter. - MaxExpDataBufferSize - UDINT- (16 * 1024) - ExpData for Profinet Device 