Services (GVL)ΒΆ

Attributes:
qualified_only
InOut:

Scope

Name

Type

Initial

Comment

Constant

SG_Device

UINT

16#1

Service Groups

SG_Application

UINT

16#2

SG_Monitoring

UINT

16#3

SG_Visualization

UINT

16#4

SG_IecVarAccess

UINT

16#9

SG_TraceManager

UINT

16#F

SG_AlarmManager

UINT

16#18

SG_Monitoring2

UINT

16#1B

SG_TrendStorage

UINT

16#1E

SRV_DevGetTargetId

UINT

16#1

Device Services

SRV_DevLogin

UINT

16#2

SRV_DevLogout

UINT

16#3

TAG_DevLoginUsername

UINT

16#10

TAG_DevLoginPassword

UINT

16#11

TAG_DevLoginReplyResult

UINT

16#20

TAG_DevLoginReplySessionId

UINT

16#21

TAG_DevLoginCryptType

UINT

16#22

TAG_DevLoginCryptChallenge

UINT

16#23

TAG_DevLoginReplySettingFlags

UINT

16#24

TAG_DevLoginCredentials

UINT

16#81

TAG_DevLoginReply

UINT

16#82

TAG_DevLogout

UINT

16#0

TODO: correct tag when this is implemented in the runtime

SRV_AppLogin

UINT

16#1

TODO: tags for answer of device login Application Services

SRV_AppLogout

UINT

16#2

TAG_AppLogin

UINT

16#1

TAG_AppDesc

UINT

16#81

TAG_AppName

UINT

16#1

TAG_AppRights

UINT

16#11

TAG_AppId

UINT

16#11

TAG_AppResult

UINT

16#10

TAG_AppReply

UINT

16#81

TAG_AppLogout

UINT

16#0

TODO: correct tag

SRV_MonMonitoringListOnce

UINT

16#1

Monitoring Services

SRV_MonWriteVariables

UINT

16#2

TAG_Monitoring

UINT

16#81

TAG_MonApplication

UINT

16#10

TAG_MonSimpleDataType

UINT

16#11

TAG_MonStackRelative

UINT

16#12

only to be complete, probably not important

TAG_MonCompoData

UINT

16#13

TAG_MonVarId

UINT

16#14

TAG_MonParameterType

UINT

16#15

TAG_MonBit

UINT

16#18

TAG_PropertyCallRef

UINT

16#20

TAG_MonErrorResponse

UINT

16#1

TAG_MonReply

UINT

16#1

SRV_Mon2Read

UINT

16#1

Monitoring 2 Services

SRV_Mon2Write

UINT

16#2

TAG_Mon2AppHeader

UINT

16#1

TAG_Mon2ReadExpList

UINT

16#2

TAG_Mon2WriteExpList

UINT

16#3

TAG_Mon2ReadValueList

UINT

16#40

TAG_Mon2ReadError

UINT

16#41

SRV_IecVarAcc_Register_Var_List

UINT

16#1

Symbolic (IecVarAccess) Monitoring services

SRV_IecVarAcc_UnRegister_Var_List

UINT

16#2

SRV_IecVarAcc_Read_Var_List

UINT

16#3

SRV_IecVarAcc_Write_Var_List

UINT

16#4

SRV_IecVarAcc_Read_Vars

UINT

16#5

SRV_IecVarAcc_Write_Vars

UINT

16#6

TAG_IecVarAcc_Varlist_Handle

UINT

16#10

TAG_IecVarAcc_Flags

UINT

16#13

TAG_IecVarAcc_Result

UINT

16#14

TAG_IecVarAcc_Num_Of_Vars

UINT

16#18

TAG_IecVarAcc_Var

UINT

16#19

TAG_IecVarAcc_Var2

UINT

16#1A

TAG_IecVarAcc_Var_Access_Info

UINT

16#1B

TAG_IecVarAcc_Var_Error

UINT

16#1C

TAG_IecVarAcc_Var_Read

UINT

16#1D

TAG_IecVarAcc_Var_Write

UINT

16#1E

TAG_IecVarAcc_Var_Result

UINT

16#20

TAG_IecVarAcc_Var_Name

UINT

16#21

TAG_IecVarAcc_Var_ClientHandle

UINT

16#23

TAG_IecVarAcc_Var_NameList_Opt

UINT

16#24

TAG_GeneralError

UINT

16#FF7F

TAG_IecVarAcc_PEERADDRESS : UINT := 16#81; TAG_IecVarAcc_PEERADDRESS_INFO : UINT := 16#11; TAG_IecVarAcc_PEERADDRESS_COMPONENT : UINT := 16#12; TAG_IecVarAcc_RESULT : UINT := 16#14; TAG_IecVarAcc_NAME_LEN : UINT := 16#15; TAG_IecVarAcc_NAME : UINT := 16#16; TAG_IecVarAcc_UPDATERATE : UINT := 16#17; TAG_IecVarAcc_VAR : UINT := 16#19; TAG_IecVarAcc_VAR2 : UINT := 16#1A; TAG_IecVarAcc_VAR_WRITE : UINT := 16#1E; TAG_IecVarAcc_VAR_HANDLE : UINT := 16#1F; TAG_IecVarAcc_TIMESTAMP : UINT := 16#22;

TAG_ExtendedErrorInfo

UINT

16#FF7E

SRV_AlmGetCount

UINT

16#81

Alarm manager services

SRV_AlmGetAlarms

UINT

16#82

SRV_AlmGetAlarms2

UINT

16#83

TAG_AlmAppName

UINT

16#1

Tags for the requests

TAG_AlmAlarmGroups

UINT

16#2

TAG_AlmAlarmClasses

UINT

16#3

TAG_AlmPriority

UINT

16#4

TAG_AlmRowSpecification

UINT

16#5

TAG_AlmRowId

UINT

16#6

TAG_AlmGetCountReply

UINT

16#1

Tags for the responses

TAG_AlmGetAlarmsReply

UINT

16#82

TAG_AlmGetAlarmsError

UINT

16#1

TAG_AlmGetAlarmsRows

UINT

16#2

TAG_AlmGetAlarmsRowId

UINT

16#3

TAG_Alarms2Alarm

UINT

16#84

TAG_GetAlarms2AlarmConstantValues

UINT

16#21

TAG_GetAlarms2AlarmLatchVariable

UINT

16#22

SRV_TrcPacketCreate

UINT

16#2

Trace manager services

SRV_TrcPacketDelete

UINT

16#3

SRV_TrcPacketComplete

UINT

16#4

SRV_TrcPacketOpen

UINT

16#5

SRV_TrcPacketClose

UINT

16#6

SRV_TrcPacketGetConfig

UINT

16#9

SRV_TrcRecordAdd

UINT

16#D

SRV_TrcPacketStart

UINT

16#A

SRV_TrcPacketStop

UINT

16#B

SRV_TrcPacketRead

UINT

16#7

SRV_TrcPacketResetTrigger

UINT

16#10

SRV_TrcPacketStore

UINT

16#11

SRV_TrcPacketRestore

UINT

16#12

SRV_TrcGetConfigFromFile

UINT

16#13

TAG_TrcPacketName

UINT

16#10

Tags for the requests

TAG_TrcPacketComment

UINT

16#16

TAG_TrcAppName

UINT

16#11

TAG_TrcTaskName

UINT

16#12

TAG_TrcEveryNCycles

UINT

16#13

TAG_TrcBufferEntries

UINT

16#14

TAG_TrcPacketFlags

UINT

16#15

TAG_TrcTrigger

UINT

16#86

TAG_TrcTriggerLevel

UINT

16#30

TAG_TrcTriggerEdge

UINT

16#31

TAG_TrcTriggerUpdatesAfterTrigger

UINT

16#34

TAG_TrcTriggerFlags

UINT

16#33

TAG_TrcVariable

UINT

16#83

TAG_TrcVariableAddressFlag

UINT

16#21

TAG_TrcVariableAddressArea

UINT

16#23

TAG_TrcVariableAddressOffset

UINT

16#24

TAG_TrcVariableName

UINT

16#20

TAG_TrcVariableTypeClass

UINT

16#25

TAG_TrcVariableSize

UINT

16#26

TAG_TrcPacketHandle

UINT

16#40

TAG_TrcError

UINT

16#FF7F

TAG_TrcGraphType

UINT

16#27

TAG_TrcGraphColor

UINT

16#28

TAG_TrcParameterId

UINT

16#29

TAG_TrcParameterModuleType

UINT

16#30

TAG_TrcParameterInstance

UINT

16#31

TAG_TrcActivateMinWarning

UINT

16#32

TAG_TrcCriticalLowerLimit

UINT

16#33

TAG_TrcMinWarningColor

UINT

16#34

TAG_TrcActivateMaxWarning

UINT

16#35

TAG_TrcCriticalUpperLimit

UINT

16#36

TAG_TrcMaxWarningColor

UINT

16#37

TAG_TrcSecondYAxis

UINT

16#38

TAG_TrcRecordHandle

UINT

16#41

TAG_TrcRecordConfiguration

UINT

16#84

TAG_TrcPacketTimestamp

UINT

16#4A

TAG_TrcTraceStateStruct

UINT

16#87

TAG_TrcTraceState

UINT

16#50

TAG_TrcTraceStartTime

UINT

16#51

TAG_TrcTriggerState

UINT

16#52

TAG_TrcTriggerTimestamp

UINT

16#53

TAG_TrcTraceChangeTime

UINT

16#55

TAG_TrcRecordBuffer

UINT

16#42

TAG_TrcRecordResult

UINT

16#47

TAG_TrcCondition

UINT

16#85

TAG_TrcFileName

UINT

16#4C

TAG_TrcInstanceArea

UINT

16#43

TAG_TrcInstanceOffset

UINT

16#44

TAG_TrcPropertyArea

UINT

16#45

TAG_TrcPropertyOffset

UINT

16#46

SRV_VISU_USER_MGMT_GETUSERCOUNT

UINT

16#8

Visu user mgmt services

SRV_VISU_USER_MGMT_GETUSERS

UINT

16#9

SRV_VISU_USER_MGMT_CHECKCHANGEUSER

UINT

16#A

SRV_VISU_USER_MGMT_GETSETDB

UINT

16#B

TAG_VisuUserMgmtAppName

UINT

16#1

Tags for the requests

TAG_VisuUserMgmtDBID

UINT

16#2

TAG_VisuUserMgmtREQVersion

UINT

16#3

TAG_VisuUserMgmtStartIndex

UINT

16#4

TAG_VisuUserMgmtEndIndex

UINT

16#5

TAG_VisuUserMgmtFlags

UINT

16#6

TAG_VisuUserMgmtUserChangeType

UINT

16#7

TAG_VisuUserMgmtIndex

UINT

16#8

TAG_VisuUserMgmtUser

UINT

16#9

TAG_VisuUserMgmtGetUserCountReply

UINT

16#1

Tags for the responses

TAG_VisuUserMgmtGetUsersReply

UINT

16#2

TAG_VisuUserMgmtCheckChangeUserReply

UINT

16#3

TAG_VisuUserMgmtGetSetDBReply

UINT

16#4

SRV_TrendGetMinMaxTimestamps

UINT

16#83

Trend storage services

SRV_TrendReadTrendData

UINT

16#84

TAG_TrendApplicationName

UINT

16#1

Tags for the requests

TAG_TrendPacketName

UINT

16#2

TAG_TrendTimestamps

UINT

16#3

TAG_TrendVariables

UINT

16#4

TAG_TrendError

UINT

16#1

Tags for the responses

TAG_TrendGetMinMaxTimestamps

UINT

16#2

TAG_TrendCountVariables

UINT

16#3

TAG_TrendReadTrendDataVariables

UINT

16#85

TAG_TrendRelevantVariables

UINT

16#86

SUBT_TrendReadTrendDataVariable

UINT

16#5

TAG_TrendReadTrendDataTimestamps

UINT

16#6

TAG_TrendReadTrendDataData

UINT

16#7

SUBT_TrendRelevantVariable

UINT

16#8

TAG_TrendReadTrendDataValidity

UINT

16#9

TAG_TrendReadTrendDataPacket

UINT

16#A

SUBT_TrendVariableDescription

UINT

16#9

SUBT_TrendAttachedYAxis

UINT

16#A

SUBT_TrendLineProperties

UINT

16#B