Services (GVL)ΒΆ
- Attributes:
qualified_only- InOut:
Scope
Name
Type
Initial
Comment
Constant
SG_Device
UINT16#1
Service Groups
SG_Application
UINT16#2
SG_Monitoring
UINT16#3
SG_Visualization
UINT16#4
SG_IecVarAccess
UINT16#9
SG_TraceManager
UINT16#F
SG_AlarmManager
UINT16#18
SG_Monitoring2
UINT16#1B
SG_TrendStorage
UINT16#1E
SRV_DevGetTargetId
UINT16#1
Device Services
SRV_DevLogin
UINT16#2
SRV_DevLogout
UINT16#3
TAG_DevLoginUsername
UINT16#10
TAG_DevLoginPassword
UINT16#11
TAG_DevLoginReplyResult
UINT16#20
TAG_DevLoginReplySessionId
UINT16#21
TAG_DevLoginCryptType
UINT16#22
TAG_DevLoginCryptChallenge
UINT16#23
TAG_DevLoginReplySettingFlags
UINT16#24
TAG_DevLoginCredentials
UINT16#81
TAG_DevLoginReply
UINT16#82
TAG_DevLogout
UINT16#0
TODO: correct tag when this is implemented in the runtime
SRV_AppLogin
UINT16#1
TODO: tags for answer of device login Application Services
SRV_AppLogout
UINT16#2
TAG_AppLogin
UINT16#1
TAG_AppDesc
UINT16#81
TAG_AppName
UINT16#1
TAG_AppRights
UINT16#11
TAG_AppId
UINT16#11
TAG_AppResult
UINT16#10
TAG_AppReply
UINT16#81
TAG_AppLogout
UINT16#0
TODO: correct tag
SRV_MonMonitoringListOnce
UINT16#1
Monitoring Services
SRV_MonWriteVariables
UINT16#2
TAG_Monitoring
UINT16#81
TAG_MonApplication
UINT16#10
TAG_MonSimpleDataType
UINT16#11
TAG_MonStackRelative
UINT16#12
only to be complete, probably not important
TAG_MonCompoData
UINT16#13
TAG_MonVarId
UINT16#14
TAG_MonParameterType
UINT16#15
TAG_MonBit
UINT16#18
TAG_PropertyCallRef
UINT16#20
TAG_MonErrorResponse
UINT16#1
TAG_MonReply
UINT16#1
SRV_Mon2Read
UINT16#1
Monitoring 2 Services
SRV_Mon2Write
UINT16#2
TAG_Mon2AppHeader
UINT16#1
TAG_Mon2ReadExpList
UINT16#2
TAG_Mon2WriteExpList
UINT16#3
TAG_Mon2ReadValueList
UINT16#40
TAG_Mon2ReadError
UINT16#41
SRV_IecVarAcc_Register_Var_List
UINT16#1
Symbolic (IecVarAccess) Monitoring services
SRV_IecVarAcc_UnRegister_Var_List
UINT16#2
SRV_IecVarAcc_Read_Var_List
UINT16#3
SRV_IecVarAcc_Write_Var_List
UINT16#4
SRV_IecVarAcc_Read_Vars
UINT16#5
SRV_IecVarAcc_Write_Vars
UINT16#6
TAG_IecVarAcc_Varlist_Handle
UINT16#10
TAG_IecVarAcc_Flags
UINT16#13
TAG_IecVarAcc_Result
UINT16#14
TAG_IecVarAcc_Num_Of_Vars
UINT16#18
TAG_IecVarAcc_Var
UINT16#19
TAG_IecVarAcc_Var2
UINT16#1A
TAG_IecVarAcc_Var_Access_Info
UINT16#1B
TAG_IecVarAcc_Var_Error
UINT16#1C
TAG_IecVarAcc_Var_Read
UINT16#1D
TAG_IecVarAcc_Var_Write
UINT16#1E
TAG_IecVarAcc_Var_Result
UINT16#20
TAG_IecVarAcc_Var_Name
UINT16#21
TAG_IecVarAcc_Var_ClientHandle
UINT16#23
TAG_IecVarAcc_Var_NameList_Opt
UINT16#24
TAG_GeneralError
UINT16#FF7F
TAG_IecVarAcc_PEERADDRESS : UINT := 16#81; TAG_IecVarAcc_PEERADDRESS_INFO : UINT := 16#11; TAG_IecVarAcc_PEERADDRESS_COMPONENT : UINT := 16#12; TAG_IecVarAcc_RESULT : UINT := 16#14; TAG_IecVarAcc_NAME_LEN : UINT := 16#15; TAG_IecVarAcc_NAME : UINT := 16#16; TAG_IecVarAcc_UPDATERATE : UINT := 16#17; TAG_IecVarAcc_VAR : UINT := 16#19; TAG_IecVarAcc_VAR2 : UINT := 16#1A; TAG_IecVarAcc_VAR_WRITE : UINT := 16#1E; TAG_IecVarAcc_VAR_HANDLE : UINT := 16#1F; TAG_IecVarAcc_TIMESTAMP : UINT := 16#22;
TAG_ExtendedErrorInfo
UINT16#FF7E
SRV_AlmGetCount
UINT16#81
Alarm manager services
SRV_AlmGetAlarms
UINT16#82
SRV_AlmGetAlarms2
UINT16#83
TAG_AlmAppName
UINT16#1
Tags for the requests
TAG_AlmAlarmGroups
UINT16#2
TAG_AlmAlarmClasses
UINT16#3
TAG_AlmPriority
UINT16#4
TAG_AlmRowSpecification
UINT16#5
TAG_AlmRowId
UINT16#6
TAG_AlmGetCountReply
UINT16#1
Tags for the responses
TAG_AlmGetAlarmsReply
UINT16#82
TAG_AlmGetAlarmsError
UINT16#1
TAG_AlmGetAlarmsRows
UINT16#2
TAG_AlmGetAlarmsRowId
UINT16#3
TAG_Alarms2Alarm
UINT16#84
TAG_GetAlarms2AlarmConstantValues
UINT16#21
TAG_GetAlarms2AlarmLatchVariable
UINT16#22
SRV_TrcPacketCreate
UINT16#2
Trace manager services
SRV_TrcPacketDelete
UINT16#3
SRV_TrcPacketComplete
UINT16#4
SRV_TrcPacketOpen
UINT16#5
SRV_TrcPacketClose
UINT16#6
SRV_TrcPacketGetConfig
UINT16#9
SRV_TrcRecordAdd
UINT16#D
SRV_TrcPacketStart
UINT16#A
SRV_TrcPacketStop
UINT16#B
SRV_TrcPacketRead
UINT16#7
SRV_TrcPacketResetTrigger
UINT16#10
SRV_TrcPacketStore
UINT16#11
SRV_TrcPacketRestore
UINT16#12
SRV_TrcGetConfigFromFile
UINT16#13
TAG_TrcPacketName
UINT16#10
Tags for the requests
TAG_TrcPacketComment
UINT16#16
TAG_TrcAppName
UINT16#11
TAG_TrcTaskName
UINT16#12
TAG_TrcEveryNCycles
UINT16#13
TAG_TrcBufferEntries
UINT16#14
TAG_TrcPacketFlags
UINT16#15
TAG_TrcTrigger
UINT16#86
TAG_TrcTriggerLevel
UINT16#30
TAG_TrcTriggerEdge
UINT16#31
TAG_TrcTriggerUpdatesAfterTrigger
UINT16#34
TAG_TrcTriggerFlags
UINT16#33
TAG_TrcVariable
UINT16#83
TAG_TrcVariableAddressFlag
UINT16#21
TAG_TrcVariableAddressArea
UINT16#23
TAG_TrcVariableAddressOffset
UINT16#24
TAG_TrcVariableName
UINT16#20
TAG_TrcVariableTypeClass
UINT16#25
TAG_TrcVariableSize
UINT16#26
TAG_TrcPacketHandle
UINT16#40
TAG_TrcError
UINT16#FF7F
TAG_TrcGraphType
UINT16#27
TAG_TrcGraphColor
UINT16#28
TAG_TrcParameterId
UINT16#29
TAG_TrcParameterModuleType
UINT16#30
TAG_TrcParameterInstance
UINT16#31
TAG_TrcActivateMinWarning
UINT16#32
TAG_TrcCriticalLowerLimit
UINT16#33
TAG_TrcMinWarningColor
UINT16#34
TAG_TrcActivateMaxWarning
UINT16#35
TAG_TrcCriticalUpperLimit
UINT16#36
TAG_TrcMaxWarningColor
UINT16#37
TAG_TrcSecondYAxis
UINT16#38
TAG_TrcRecordHandle
UINT16#41
TAG_TrcRecordConfiguration
UINT16#84
TAG_TrcPacketTimestamp
UINT16#4A
TAG_TrcTraceStateStruct
UINT16#87
TAG_TrcTraceState
UINT16#50
TAG_TrcTraceStartTime
UINT16#51
TAG_TrcTriggerState
UINT16#52
TAG_TrcTriggerTimestamp
UINT16#53
TAG_TrcTraceChangeTime
UINT16#55
TAG_TrcRecordBuffer
UINT16#42
TAG_TrcRecordResult
UINT16#47
TAG_TrcCondition
UINT16#85
TAG_TrcFileName
UINT16#4C
TAG_TrcInstanceArea
UINT16#43
TAG_TrcInstanceOffset
UINT16#44
TAG_TrcPropertyArea
UINT16#45
TAG_TrcPropertyOffset
UINT16#46
SRV_VISU_USER_MGMT_GETUSERCOUNT
UINT16#8
Visu user mgmt services
SRV_VISU_USER_MGMT_GETUSERS
UINT16#9
SRV_VISU_USER_MGMT_CHECKCHANGEUSER
UINT16#A
SRV_VISU_USER_MGMT_GETSETDB
UINT16#B
TAG_VisuUserMgmtAppName
UINT16#1
Tags for the requests
TAG_VisuUserMgmtDBID
UINT16#2
TAG_VisuUserMgmtREQVersion
UINT16#3
TAG_VisuUserMgmtStartIndex
UINT16#4
TAG_VisuUserMgmtEndIndex
UINT16#5
TAG_VisuUserMgmtFlags
UINT16#6
TAG_VisuUserMgmtUserChangeType
UINT16#7
TAG_VisuUserMgmtIndex
UINT16#8
TAG_VisuUserMgmtUser
UINT16#9
TAG_VisuUserMgmtGetUserCountReply
UINT16#1
Tags for the responses
TAG_VisuUserMgmtGetUsersReply
UINT16#2
TAG_VisuUserMgmtCheckChangeUserReply
UINT16#3
TAG_VisuUserMgmtGetSetDBReply
UINT16#4
SRV_TrendGetMinMaxTimestamps
UINT16#83
Trend storage services
SRV_TrendReadTrendData
UINT16#84
TAG_TrendApplicationName
UINT16#1
Tags for the requests
TAG_TrendPacketName
UINT16#2
TAG_TrendTimestamps
UINT16#3
TAG_TrendVariables
UINT16#4
TAG_TrendError
UINT16#1
Tags for the responses
TAG_TrendGetMinMaxTimestamps
UINT16#2
TAG_TrendCountVariables
UINT16#3
TAG_TrendReadTrendDataVariables
UINT16#85
TAG_TrendRelevantVariables
UINT16#86
SUBT_TrendReadTrendDataVariable
UINT16#5
TAG_TrendReadTrendDataTimestamps
UINT16#6
TAG_TrendReadTrendDataData
UINT16#7
SUBT_TrendRelevantVariable
UINT16#8
TAG_TrendReadTrendDataValidity
UINT16#9
TAG_TrendReadTrendDataPacket
UINT16#A
SUBT_TrendVariableDescription
UINT16#9
SUBT_TrendAttachedYAxis
UINT16#A
SUBT_TrendLineProperties
UINT16#B