Item (FB)ΒΆ
FUNCTION_BLOCK PUBLIC FINAL Item IMPLEMENTS IOPCUAClientMonitoredItemCallback
This function module represents an item inside a Subscription.
Usage example:
_aItems : ARRAY[0..1] OF UA.Item := [
    (
        eType := UA.IEC_UDINT,
        pValue := ADR(udiValue),
        psNodeId := ADR('ns=4;s=pathudiValue')
    ),
    (
        eType := UA.IEC_STRING,
        pValue := ADR(sValue),
        udiSize := SIZEOF(sValue),
        psNodeId := ADR('ns=4;s=path.sValue')
    )
];
- InOut:
- Scope - Name - Type - Initial - Comment - Input - eType- item type - pValue- POINTER TO BYTE - target location of IEC value If eType = IEC_ARRAY pValue is a pointer to ArrayValueIf eType = IEC_STRUCT pValue is a pointer to StructValueIf eType = IEC_UNION pValue is a pointer to UnionValue- udiSize- UDINT(max) size of this item.with the exception of the types- [UWX]?STRINGthis value is calculated by the library.If eType = IEC_ARRAY udiSize should be SIZEOF(UA.ArrayValue)If eType = IEC_STRUCT udiSize should be SIZEOF(ARRAY[0..n] OF UA.StructValue)If eType = IEC_UNION udiSize should be SIZEOF(UA.UnionValue)- psNodeId- POINTER TO NODEID - NodeId of the variable related to the servers address space - lrInterval- LREAL- xEnabled- BOOL- TRUE - psEncodingId- POINTER TO NODEID EncodingId of the variables type related to the servers address spaceOnly neccecary for top level descriptions of a- STRUCTmember
Methods:
Structure:
